Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 2009-4-13 SfEI GcJ~ " .:caJ & Construction SeIVires 11:"'lltlrt;"I'.'~~'IIII~.IH. April 13, 2009 Project No. Report No. 2097017 E-22756 Mr. 'Charlie McClain Mcintyre Construction PO Box 2523 Eugene, Oregon 97402 FINAL SUMMARY.REPORT Enterprise Rent-A-Car 4396 Main Street Springfield, Oregon Building Permit No, C8-00589 Dear Mr. McClain, This letter confirms that FEI Testing & Inspection, Inc, performed special inspection services in a~cordance with IBC and as directed by our client for the above-referenced project. We were employed to provide continuous or periodic inspection on specific dates, as documented per our special inspection reports for: , Dearthwork 0structural masonry 0epoxy anchors 0reinforced concrete Dbolts installed in concrete Dstructural welding (shoplfield) Dhigh-strength bolts Dspray applied fireproofing Based upon our' obserVations 'and written reports of this work, it is our judgment that the inspected work was performed, to the best of our knowledge, in.accordance with the approved plans, specifications, change orders and/or' structural engineer's instructions, and applicable provisions of Chapter 17 of the International Building Code, except as noted on the attached report number E-22357, dated 02-09-09, . Respectfully, /h.~~~'_ Mi~hael C, M~r- Technical Manager c: City of Springfield Attachment . MLM:sc. RE:CEllltc 4PR 17 lOog This rE!port and/or enclosed test data is the confidential property of the client to whom It is addressed and pertains to the specific process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part thereof be disclosed without FEI Testing & Inspection, Inc.'s written authorization. 7fiJ WI CaneII A~' CavaJtis, Clreg::n 97330, phone (541) 757-4698 ,fax (541) 757-2991 29540 BAirportRoad' Eugene, Clreg::n 97402. phone (541)684-3849' fax (541 )6MJ851 63050 Corporate Place, Suite 2 . Bend, Oregon 97701 . phone (541) 3824844 . fax (541 ) 382-4846 . ~...., ~rt Geotechnical & Construction Savio3s' Compressive Strength of Concrete (ASTM C 39) 11~'lnlrw;"I~.':II;"lllltlWl CLIENT Mr. Charlie McClain PROJECT Enterprise Rent-A-Car DATE 04-13-09 Mcintyre Construction 4396 Main Street PROJECT NO. 2097017 PO Box 2523 Sprin9field, Oregon REPORT NO, 6320 Eugene, Oregon 97402 B.P,NO. C8-00589 DATE CAST STRENGTH REQUIRED STRENGTH PLACED PRODUCT CODE ADDITIVES LOAD NO.. CONCRETE TEMP AIR TEMP POUR LOCATION CAST BY D. Delatte DATE RECEIVED SPECIMEN SIZE SUPPLIER MAX SIZE AGG. AIR CONTENT SLUMP TIME SPECIMEN STORAGE 04-06-09 3500 psi 3500 psi 35-IN SACKS CEMENT 1 TICKET NO, 3353674 6r F YARDAGE 10.75 OF 4r F WEATHER. Clear Slab on grade for office and car wash areas. 38.0f LOAD 1 SAMPLED North end of office area. TEST DATE 04-13-09 05-04-09 05-04-09 Hold AGE (DAYS) 7 28 28 AREA (IN') 12.56 WEIGHT (LBS) 8.52 TOTAL LOAD (LBS) 45920 COMPRESSIVE STRENGTH (PSn 3660 AVERAGE STRENGTH (PSn TIME OF TEST 8:20 AM 04-07-09 4" x8" Knife River 314" 5" 7:35AM ASTM C31 TYPE OF FRACTURE- 4 .*1 - End Cones 2 - Cone/Split 3 - Columnar 4 - Diagonal 5 - Side (top and bottom) 6 - Side (top or bottom) REMARKS: Ron (Mcintyre) was advised of on-site test results. \ Reviewed By: /1.t:~ Michael L MeyeP Technical Manager c: City of Springfield MLM:sc This report and/or enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part thereof be disclosed without FEI Testing & Inspection, Inc.'s written authorization. 7f{) tw Carla! Averue' CavaJIis. Oegm 97330. phore (541) 757-4698, fax (541) 757-2991 29540 B Airpal Rood . Eugene, Oegm 97402 . phore (541) 684-3849 . fax (541) tJ84.J851 630f{) Corporate Place, Su~e2 .Bend, Oregon 97701 . phone (541) 382-4844 . fax (541) 382-4846 1>~ (' ~ ~t- ./ u'~ <<'.0 ~ 9rP~1 .. ... cOJi1 Page 1 of 1 11~'.I~ICl;1IIt~'~~'11'111W!11. Geotechnical & Conslrudion Servires Daily Field Report Client: Mr. Charlie McClain Project: Enterprise Rent-A-Car Date: 02-09-09 Mcintyre Construction 4396 Main Street Project No,: 2097017 PO Box 2523 Springfield, Oregon Report No.: E-22357 Eugene, Oregon 97402 Inspector: D. Delatte ID No,: 1080867-88 ICC Inspection of: Reinforcing Steel Weather: Overcast Continuous Inspection: 0 Contractor: Mcintyre Construction BPNo.: C8-00589 Periodic Inspection: 0 Performed inspection on reinforcing steel for perimeter continuous footing and one (1) interior continuous footing' at. north wall of car wash area. Reinforcing steei was checked for grade, size, lap, placement and clearance. The #4 dowels for tie between siab and footing are not installed. Contractor stated dowels will be epoxied at a later date and would contact EOR regarding embed depth of dowels.. . Mcintyre representative was asked to notify our office when additional services are needed. To the best of our knowledge, the work inspected was in accordance with plans dated 04-10-08 and applicable workmanship provisions of the I.B.C., except if noted above. .Reviewed By: Ih.<-j,~ Michael L. Meyer Technical Manager \ c: City of Springfield MLM:sc This report and/or enclosed test data Is the confidential property of the client to whom it is addressed and pertains to the specific process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part thereof be disclosed without FEI Testing & Inspection, lnc.'s written authorization. 7f:JJ WI ComeIIAvenue' CavaiIis, 0regJn 97330' phme(541) 757-4698 . fax (541) 757-2991 29540 BAirpalRood' Eugene, 0regJn 97402, pIme (541) 684-3849 . fax (541) 684J851 63050 Corporate Piace, Suite 2 ' Bend, Oregon 97701 . phone (541) 382-4844 . fax (541) 382-4846