. Daily Field Report .
Client:
Mr. Charlie McClain'
Mcintyre Construction
PO Box 2523
Eugene, Oregon 97402
I
Project: Ent~rprise Rent-A-Car
4396 Main Street
Spri'ngfield, Oregon
I
,
I
Date:
Project No.:
Report No.:
Inspector:
10 No.:
04-06-09
2097017
E-22695
D. Delatte
1080867-88
ICC
Inspection of: Reinforced Concrete
Contractor: Mcintyre Construction
Weather:
BPNo::
I
Cle<?r
C8-00589
I
Continuous Inspection: 0
Periodic Inspection: 0
Performed inspection on the reinforcing steel for slab on grade (4") at office area and
slab on grade (6") for carwash area. Reinforcing steel was checked for grade, size,
lap, placement and clearance. Reinforcing steel was secured and supported above
grade on concrete dobie blocks. I
Observed the placement of 30.0 of 38.0 yards of Knife River 3500 psi concrete (mix 35-
IN) in area noted above. Concrete was placed by pump and was manually
consolidated. Cast one (1) set of four (4) 4" x 8" concrete test cylinders from load 1.
Slump - 5"; air temperature - 47F; concrete temperature - 67F
Ron (Mcintyre Construction) was notified of our on-site test results.
I
To the best of our knowledge, the work inspected was in accordance with plans dated
04-10-08 and applicable workmanship prov,isions of the I.B.C., except if noted above...
Reviewed By:
/h, I~
Michael L. Meyer
Technical Manager
c:
City of Springfield
MLM:sc
RECEIVED
APR 1 3 2009
This report andlor enclosed test data is the confidential property of.the client to whom it is addressed and pertains to the specific
process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full andlor any part
thereof be disclosed without FEI Testing & Inspection, loc.'s written authorization.
7m rwv Cornell Avenue. CavaI~, Oegoo 97330, phone (541) 757-4698' fax (541) 757-2991
29540 B Airport Road . Eugene, 0eg0097402' phone (541) 684-3849 'fax(541)684-3851
63050 Corporate Place, Suite 2 . Bend, Oregon 97701 . phone (541) 3824844 . fax (541) 382-4846
Sftl
Page 1 of 1
11~'II~lrt;1Ilf.'~~'llll~1I!ll!
Geotechnical & Construdion Services
Daily Field Report
Client: EWEB Project: Hayden Bridge Water Filtration Date: 04-09-09
500E. 41h Ave. Plant Expansion Project No.: 2087168
Eugene, Oregon Springfield, Oregon Report No.: E-22725
Inspector: D. Delatte
10 No.: 1080867-84
ICC
Inspection of: Masonry Weather: Overcast . Continuous Inspection: 0
Contractor: WildishBuilding Co. BPNo.: 2008-00225 Periodic Inspection: 0
Performed inspection on the reinforcing steel in 6" CMU wall in the coagulant building
(8' to 12'). Reinforcing steel was checked for grade, size, lap, placement and
clearance, where applicable. Reinforced cells were relatively free of excess mortar
projections.
Observed the placement of site batched high strength Sakrete Concrete Mix by bucket
and mechanically consolidated after placement. Only reinforced cells and bond beams
were grouted solid. Slump - :t9"; air temperature - 52F; grout temperature - 54F.
Jessie (Art's Masonry) was asked to notify our office when additional services are
needed.
To the best of our knowledge, the work insbected was in accordance.with plans dated
02/2008, masonry submittals and applicaple workmanship provisions of the I.B.C.,
except if noted above. ,I
Reviewed By:
111.1:.~~
Michael L~"M~er
Technical Manager
c:
EWEB- Mike Stickling (email)
EWEB- Wally McCullough (em ail)
OBEC- Pete Slocum (email)
Wildish Building Co.- Kevin Fitzjarrell (em ail)
Wildish Building CO.-.Jake Stucky (em all)
City of Springfield
MLM:sc
This report and/or enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific
process and/or material evaluated. As such, information contained herein shall not be reproduced in.part or full and/or any part
thereof be disclosed without FEI Testing,& Inspection, Inc.'s written. authorization.
. 7fiJ rwv ComeII AValue' CavaI1is, 0Bgcn 97330' phone (541 ) 757-4698, fax (541) 757-2991
29540 B Airport Road . Eugene, Oegoo 97402 . phone (541) 684-3849 . fax (541) 684-3851
63050 Corporate Place, Suite 2. Bend, Oregon ~7701 . phone (541) 3824844. fax (541) 382-4846
Rl:.cEIVED
APR 1 4 1009
~""'I
~ft
Page 1 of l'
.~~'nltLI't;.I~..'~;all'lIl.II'll:ll
Geotechnical & Construction Services
Daily Field Report
Client:
EWEB
500E. 4th Ave.
Eugene, Oregon
Project:
Hayden Bridge Water Filtration
Plant Expansion
Springfield, Oregon
Date:
Project No.:
Report No.:
Inspector:
10 No.:
04-06-09
2087168
E-22699
D. Delatte
1080867-84
ICC
Inspection of: Masonry
Contractor: Wildish Building Co:
. Weather: Clear
BP No.: 2008-00225
Continuous Inspection: D
Periodic Inspection: 0
Performed preliminary reinforcing steel inspection for 6" CMU wall in coagulant building
(slab to 4'). Reiriforcingsteel was checked for grade, size, lap, placement and
clearance, where applicable. Reinforced cells were relatively clean and free of excess'
mortar projections. The un-reinforced cells were blocked off with grout stop. Final
inspection will be performed prior to grout placement.
To the best of our knowledge, the work inspected was in accordance with plans dated
02/2008 and applicable workmanship provisions of the I.B.C., except if noted above.
Reviewed By:
;1 :1..17-
Michael L. Meyer
Technical Manager
c:
EWEB- Mike Stickling (email)
EWEB- Wally McCullough (em ail)
OBEC- Pete Slocum (em ail)
Wildish Building Co.- Kevin Fitzjarrell (emaii)
Wildish Building Co.- Jake Stucky (em ail)
City of Springfield
MlM:sc
\
This report andlor enclosed test data is the confidential property of the client to 'Nhom it is addressed and pertains to the specific
process and/or material'evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part
thereof be disclosed without FEI Testing & Inspection, Inc.'s written authorization. .
750 rwv ComeIAvenue' Cavallis, Oegoo 97330, phone (541) 757-4698, fax (541) 757-2991
29540 BAirport Road. Eugene, Oegoo 97402, phone (541)684-3849' fax (541) 684-3851
. 63050 Corporate Place, Suite 2 . Bend, Oregon 97701 . phone (541) 3824844. fax (541) 382-4846