Loading...
HomeMy WebLinkAboutPermit Correspondence 1998-7-31 r. 4- ! CITY MANAGER'S OFFICE CITY RECORDER COMMUNICATIONS 225 FIFTH STREIT SPRINGFIELD, OR 97477 (541) 726-3700 FAX (541) 726-2363 ~" .. . July31,1998 Ron Wilson Senior Engineer Eugene Water and Electric Board 500 East 4th ^ venue Eugene, Oregon 97440 '* ~ RE: 3997 Marcola Road, Springfield, Oregon Dear Mr. Wilson: I am writing in regards to your. letter dated July 21, 1998 requesting written confirmation on electrical disconnect locations. At the time of the original installation of the disconnects at the above stated location, the 1990 National Electrical Code was in effect. The Code at that time stated in part that all disconnects shall be installed at a readily accessible location either outside ora building, or inside the nearest point of entrance or the service conductors. Based on the above information, I eonfiml the following: . The buildings and the transformers are under the single management of Eugene Water and Electric 130ard and their employees. Only qualified personnel will rllaintain and operate the equipment. . There are two (2) main disconnects which arc labeled identifying the location of the building disconnect. If YOll have tiny questions, or if I may provide additional information. please feel free to phone me at 726- 3663. Sincere.IY, ~ &?P.~/;~ David Gadomski Electrical Inspector fJt..~ EWEB EUg.water & Electric Board . ../ ... 500 East 4th Avenue I Post Office Box 10148 Eugene, Oregon 97440-2148 541-484-2411 Fax 541-484-3762 July 21,1998 Dave Gadomski City of Springfield Community Services Division Building Safety 225 Fifth Street Springfield, OR 97477 RE: Hayden Bridge Raw Water Intake Electric Service Dear Mr. Gadomski, This letter is to summarize our discussion at the subject site concerning the need for a service disconnect at the point of entry into the building. Based on our conversation, it was concluded that a disconnect is not required at this location for the following reasons: I, The service was installed at a time when the NEC did not require a disconnect at the point of entry into the building, 2. EWEB, being an electric utility, can be exempted from this NEC requirement. 3. Since this is a high voltage service (12 KV), qualified electrical personnel are required to operate it. The disconnect that exists for this service across the street is adequate and EWEB electric personnel are aware of its location. An additional disconnect at the building site is not necessary, Please note if there are any changes or additions to the above itcms and rcturn a signed copy of this letter as concurrence. Please contact me if there are any questions. S/i.J1 M.L: Ronald L. Wilson Senior Engineer Concurrence Date