HomeMy WebLinkAboutPermit Miscellaneous 1981-2-17 ~.. .' ~ OF SPRINGFlilll EL~CTRICA~INSPECTION R E P_T \ GlNERlRENTER: Whitsell & Whitsell Company ADDRESS: 3411 Marco1a Road. SDf1d. OR 97477 ADDRESS OF INSPECTION: Same iYPE OF SIRUCTURE: Mi 11 TYPE OF REQUEST: Annual Electrical IISE: same HEIGHT DATE: 2-17-81 WIRING METHOD: NON-METALLIC SHEA1l-IED CABLE - ARMORED CABLE CONDUIT POfIER CO: aw~GES ORDEPED: 1. Replace defective 230 V. outlet in Mr. Whitse11s office. 2. Reverse polarity in duplex receptacle in office in west shed. 3. Install conduit .to 115 v outlet in west shed office. -, fA .~ 4. Remove storage and debris from 3' area in front of maintenance shop control center. 5. Check all cords for proper polarity and'grouna continuity' in all areas. 6. Clearly identify all circuits in panelS and disconnects in all areas. 7 . Provide protection from water on a 11 behind cut off saws di sccinned. 8. Replace defective cord into cutof,f sa';oi.#2." 9. All protab1eelectrica1 equiprnent shall be bonded; All areas. 10. Secure cover on switch - receptacle box by cutoff saw in east shed. 11. Repair broken conduit to center overhead lights in east shed. 12. Repair defective flex connector'into re1ay'on.tab1e saw in 'east shed. and provide protection of cord and conduits against future' defects. 13. Remove 2 conductor. pin-up 1 ights in all areas 'and install approved fixtures and wiring method. 14. Repair defective flex connector in air compressor relay in east shed. 15. All wiring in and to planer to be property installed by an electrical contractor. 16. Properly identify and clean circuit' breakers in panel in planer control center and seal open K.O.'S'- east 'shed 17. Properly i nsta 11 ccinduit to hog from east 'shed contro 1 center. 18. Repair defective light fixture over planer in east shed. INSPECTOR: ACCCMPANIED BY: APPROVED BY: ,;' ~ (f SPRINGFIElD, . ELECTRICA~INSPECTION REPuRT OtINER/RENTER: ADDRESS OF INSPECTION: TYPE OF STRUC1URE: ADDRESS: IISE: TYPE OF REQUEST: HEIGHT PAlE : WIRING METl-tOD: NON-METALLIC SHEATIiED CABLE - ARMORED CABLE CONDUIT POt'IER CO: GlANGES ORDERED: 19. Replace defective cord to out feed tablefi'oiri planer in east sned. 20. Correct all defective wiring below planer 'outfeed table. 21. Install approved lighting and wiring ~ethod to"lighted area above time clock in east shed. 22. Reverse polarity in 115V receptacle below time'clock in east shed. 23. Install cover on motor to hog conveyor. 24. Remove sawdust below hog. 25. Repair defect'ive flex to resaw infeedmotor." 26. Repair defective flex into 'control station- at in feed end of . wedge machine. 27. Install cover on motor on planer in middle planer' shed; . 28. Repair defective flex'intoplaner head. motor in middle planer shed. 29. Replace defective cord cap on air compress'or cord in middle planer shed. 30. Replace defective cord junction box - air' compressor. 31. Replace all wiring'to planerinfeed iriotor in iriiddleplaner shed.' 32. Install conduit as wiring method to straight line rip way ~ middle planer shed. 33. Replace all wiring on glue planer in middle planer shed. 34. Replace all deTective wiring to chop saw in middle planer shed. 35. Install brace on service mast to middle planer shed and raise service drop to clear by 8'. 36. Replace all ,defectfoj'e cords 'to dciuble end trim saws in middle, planer shed. , '. '-, --. - _.. .-- - .-. . 37. Remove defective heater, repair defective' cords and remove pin-up lights to west trim saw. 38. Check control centers for proper ground. INSPECTOR: ACCQ\1PAN I ED BY: APPROVED BY: ." .TY OF SPRINGFIElD . E LEe T R I C A~ INS PEe T ION R. E P~R T ooERI RENTER: ADDRESS: ADDRESS OF INSPECTION: TYPE OF STRUClURE: . IISE: TYPE OF REQUEST: HEI GHT PATE: WIRING METHOD: NON-METALLIC SHEATHED CABLE -' ARMORED CABLE CONDUIT POtIER CO: . Ql,ANGES ORDERED: 39. Install cover on LB on sawdust bins. 40. Repair defective offset connector into gutter in north trim shed. 41. Install conduit to receptacle outlet adjacent to light over cutoff'saw in north trim shed. 42. Staple loose N.M. cable in mens room. 43. Install cover on water heater and properly install wiring to the water heater. 44. Install approved wiring method to water pump. . 45. Secure light fixture in pump house. 46. Control centers in all areas to be airHclearied arid the required 3' area to be kept clear at all times. 47. Provi de an outl et (115V) adjacenttothemotof home. .. 48. Because of the hazardous nature <if these]i sted defects';. it i srecommended that an electrical contractor make all corrections at this time. INSPECTOR: Chas. Watson ACCCMPANIED BY: . W.F. Cowles APPROVED BY: Mn 1 wi'i ght ..., , r ~ (, \" , //:. . " .', -,. . ',' . '_.. . ~-.... ........ .... .....':... . . ;Z -1 ~fl Mr. Ronald B. Clark, Superintendent Building Division Department of Public Works 346 Main Street. Springfield, Oregon 97477 . RE: Authorization for Industrial Plant Electrical Inspection Semi-Annual Annual Dear Mr. Clark:' Following our discussion with.' . . ..p ~, uJ~ , Electrical Safety Inspector, this ietter is to confirm authori- zation for the above indicated inspection of our. plant in accor- dance with OAR 22-120 Subsection 3 or OAR 22-125 Subsection 4, State of Oregon Electrical Safety Law. It is requested that 7lUt...; ~)J;fl---?_~.J /'rl~ be contacted prior to such inspection to insure that personnel .will be available to accompany the inspector. /lIeJ'! Eke'. Supervising Electrician . MSi~edj //:-/' / . " -~~/Z - -' . ~/"':'-~:t#~-: .' . )~.:';:t;,,>> ~ Lv !u::tu.LfJ.J ~ . Company Name . m~, ;e;.. SffJ'JoR- r;~~-~Ol.J;;Z , c3l.(11 Address Limited Maintenance Electrician I :. ., . CITY OF SPRINGFIELD DEPARTMENT OF PUBLIC WORKS Ronald B. Clark, Superintendent' Building Division Industrial Plant Electrical Inspection Billing Information Date .2. -/7 -,pI Firm Inspected ,W6,'t~,.!/.,f W6/t-reJ! TAr, ~ddress ...74// M;)tt'/J /a /PrI City 1 P n.;;,J . State /. /Jlp. Division Electrical Supervisor .' A/e}A! Fjp~tY'J to , Limited Maintenance License Bill To LVA/f'l'P// cf t/Lhpjj Twr. Address L'< 4/ / H:J yi t"/! /;' R.}. , City ( Pf:\I?! State /' Attention ,1)~yyt" / / /'1/ hi 't(l~/ I (Tytro. Type ~f Inspection: Annual 0 Semi-Annual c==J Arrival Time at Plant Site Iff AI? Number of Hours :2. Y.i' Id,) /1" Inspector (JL,p.h )./.{.vv1 Accompanied By ;1'/./ r f'"" ~ 1--1t.-.. .;" r f ~ Departure Time I :2 ,'3d 1'# -://;a~~ . I' _ -:.. t A -/