Loading...
HomeMy WebLinkAboutMiscellaneous Correspondence 1986-6-2 . CITY OF SPRINGFIELD . rl~Ji~":J~'~~jWd.II.w,.:u_i.l:w,.J""lIHi~IiiAU.~'~1,lH ,..I-',Jie/Ut."" ......,.,,!.&J.~....:... .I..~~-1daL.w.....~rt.lNlI~.., ~ Office of Community and Economic Development June 2, 1986 Harlow Realty Inc 2433 Marcola Road Springfield, Oregon 97477 Subject: Fire damage at 2287 Marcola Road Springfield, Oregon 4! If.'$' Dear Owner: At the request of the Springfield Fire and Life Safety Department, the Building Safety Division recently conducted an inspection of the fire damage at the above address. The inspection revealed damage which must be corrected in order for the building to comply with applicable City codes. The following items must be repaired or replaced: Structural 1. Glass was broken from the bedroom window. The Structural Specialty Code requires that replacement glass for windows in heated areas must be double insulated, or they must be insulated by storm windows which are rated with a thermal transmission factor not greater than .07. ./ ,2. Soffit material under the eave at the window where the fire occurred was burned to a degree warranting replacement. 3. Ceiling material in the east bedroom, west bedroom and hallway was damaged by the fire and water to a degree warranting replacement. 4. Wall material in the east bedroom was damaged by the fire and water to a degree warranting replacement. Electrical 5. Wiring to all electrical devices in the bedroom where the fire occurred was subjected to temperatures greater than it was designed to withstand. The insulation on this wiring was damaged, necessitating replacement of the wiring between each fixture and the wiring source. 6. The wiring to the hall light fixture must be checked for possible damage which may require replacement. Please note that installation and repair of electrical systems on property which is intended for lease, sale or rent must be done by an electrical contractor who 1iAl'~" ~.!.&1ifM!'I!f:ffMf:'Idlll 'l!'~e!lI!lll!1Iii\J!1lll......~l>ttWi"""'~~'''''''''''''''''1'''''''''''''1iJ 'IlJ!~ 225 North 5th Street Springfield, Oregon 97477 503/726-3753 . . is licensed by the State of Oregon. Permits will be required for items #3,4,5&6, or any 'additional modifications you may desire which involve, changes or additions to the structural, electrical, mechanical or plumbing systems. Required permits may be obtained from this office. Please direct all inquiries to the Springfield Building Safety Division at 726-3759. Sincerely, j~~hLL l"~" J;1!~ Jim Matteson Electrical Inspector Don Moore Building Inspector cc. Dave Puent, Building Official Mike Hudman, Fire Marshal o