Geotedri::aI & Calslrucfun Servires
Daily Field Report
Client: Mr. Charlie McClain Project: Enterprise Rent-A-Car Date: 03-04-09
Mcintyre Construction 4396 Main Street Project No.: 2097017
PO Box 2523 Springfield, Oregon Report No.: E-22500
Eugene, Oregon 97402 Inspector: D. Delatte
10 No.: 1080867-88
ICC
Inspection of: Epoxy Anchors Weather: Overcast Continuous Inspection: 0
Contractor: Mcintyre Construction BP No.: C8-00589 Periodic Inspection: It!
Observed the installation of fifty-two (52) 5/8" x 7" to 9" epoxy all thread anchors into
CMU wall near roof line for L TT20B Simpson Straps along the perimeter walls of
building. Prior to installation, the predrilled holes were cleaned with a brush and
compressed air. Verified minimum embed depth of 6". Anchors were secured with
Simpson Set 22 epoxy adhesive (ICC ES 1772/ expiration date 05-31-09).
Bob (Mcintyre Construction) was notified of on-site observations and was asked to
notify our office when additional services are needed.
To the best of our knowledge, the work inspected was in accordance with plans dated
04-10-08 and applicable workmanship provisions of the I.B.C., except if noted above.
Reviewed By:
fh.1,~_____'
Michael L: Mlfer
Technical Manager
c:
City of Springfield
MLM:sc
This report andfor enclosed test data is the confidential property of the client to whom it is addressed and pertains to the speCific
process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part
thereof be disclosed without FEI Testing & Inspection, Inc.'s written authorization.
700 NN CanelAverue' QxvaD"1S, Oreg:n 9733). phone (541) 757~' fax (541) 757-2991
29540 B Airpcxt Road . ELgJne, Oreg:n 97402 . phone (541)684J849' fax (541 )684J851
63050 Corporate Place, Su~e 2 . Bend, Oregon 97701 . phone (541) 382-4844 . fax (541) 382-4846