HomeMy WebLinkAboutPermit Field Test & Inspection Report 2009-2-17
l....~;lInfonnation
,.,~. .To Build On
Engineering . Consulting . TeSting
DAiLY FIELD R=:?ORT
,eee;ved
r . /")J1~
Date Periormed:
February 17, 2009
. ,
Ms. Lauretta Davies
Jerry's Ham" Improvement
P.O 80l: 2611
Eugene, Oregon 97402
Report Number:
722-90008-21
Client:
Project Name:
Jerry's-Warehouse Renovations
2525 Olympi~: Street1
Springfield, Oregon
Project LocatiDn:
P.O. No.:
Type of Inspection:
Z4175LD
EpDxy
Buildin9 Permit ND.: COM2008-01595
Weather: Clear
Field Observations and Comments
PerfDrmed continuDus inspection during the installation Df (11) #4 epDxied rebar dowels in the follDwing IDcatiDns: dDor
way southeast corner at approach. Prior to installatiDn the predrilled holes were cleaned using a nylDn brush and
cDmpressed air. Verified minimum embedment depth of 5 1/2 inches. The above listed epoxy anchors were installed
using Simpson Set-XP epoxy with ICC# ESR 2508. The epoxy anchors were installed in accordance with approved job-
site plans and latest revisions dated 2/9/01. Contractor stated the nuts would be tightened after epoxy has cured. To
the best of our knowledge, the work inspected was in accordance with the ~building department approved design
drawings, specifications and applicable workmanship provisions of the International Building Code.
Inspector: Pete Furlong
CCB #176269
If you have any questions regarding this report, please feel free to contact us at 541-746-9649.
Respectfully Submitted,
~Sk<{"Q(1~
Raymond Aliperti
Project Manager
c: City of Springfield
Chambers Construction - David Bakke
Robertson Sherwood Architects - Scott Stolarczyk
Metzler Engineering - Scott Metzler
THIS REPORT IS PROVIDED FOR THE INFORI:.tATION OF THE CLIENT aNL y, THE REPRODUCTION Q,c THIS REPORT. BY ANY METHOD, AND ITS TF"!ANSMITTAL TO A THIRD
,....", T, Of...'" """'h"v, (.;AvCI t oj, '-,-,1..1... if',' .~'-'. 'o'~ '" ".. ~". ~. ..m~J/efI.' ::.- :-.-.::,-~:::"::"..'.~.:;: ::::..:....:;-::::::.:.: ,-,-.:.'-HBfFE:
Professional Service Industries, Inc.. 1040-A Shelley Street. Springfield, OR 97477 . Phone 541/746.9649. Fax 541/746-7163
l.... ~;lInfonnation
,.,~. .To Build On
Engineering. Consulting. TestiD9\..L. 'L'i.' ~"~ID ~-p--,--
LV,,,~. rg=_' I'\.= !Jr-(l
Date Periormed:
February 17, 2009
Ms. Lauretta Davies
Jerry's Home Improvement
P.O Box 2611
Eugene, Oregon 97402
Report Number:
722-90008-20
Client:
Project Location:
Jerry's-Warehouse Renovations
2525 Olympic Stree,
Springfield. Oregon
Project Name:
P.O. No.:
Type of Structure:
Type of Inspection:
Z4175LD
Permit No.:
Weather:
COM2008-01595
Rain
Reinforcing Steel and Concrete
Field Observations and Comments
Performed visual inspection of reinforcing steel at the following locations: loading dock slab and approach. Reinforcingl
steel was checked for grade, size, lap, placement and clearances where applicable. Reinforcing steel was secured
using tie wire and supported on concrete dobie blocks. Reinforcing steel was placed in accordance with approved
design drawings, specifications and engineering approval for as-built. Performed visual inspection during placement of
concrete in the locations listed above. Concrete was placed by pump and mechanically consolidated. Cast one (1) set
offour (4) (6x12) concrete test cylinders. Contractor was asked to notify our office when additional services are needed.
Additional Comments: RFI to follow for as-built on siab to approach (1) one #4 at 12" center, all other rebar #5's at 12"
centers each way. To the best of our knowledge, the work inspected above was in accordance with the building
department approved design, drawings, specifications and applicable workmanship provisions of the International
Building Codes.
~oe of M~teri~1 Set #1
Supplier Knife River
Mix # 2450V02200
Slump 61/2"
Air Content 4.5%
Ambient Temperature 560
Material Temperature 69'
Time Placed 11 :05 AM
Design Strength (psi) 5,000
Number of Samples 4
Total Yardaqe Placed 50
Inspector: David Smith, ICC #0877340-88 & Pete Furlong
CCB# 176269
If you have any questions regarding this report, please feel free to contact us at 541-746-9649.
Respectfully Su~mitted,
D~;~:rJ!t(1~
Raymond Alrpertl )
Project Manager
cc: City of Springfield
Chambers Construction - David Bakke
Robertson Sherwood Architects - Scott Stolarczyk
Metzler Engineering - Scott Metzler
THIS REPORT IS PROVIDED FOR THE INFORM!.. TION OF THE CLIENT ONL Y. THE REPRODUCTION OF THIS REPORT. BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD
..... ~"v. ,,,., "'-' ",,'''<on. '^' "'" r ''''Tl-lnr iT TJ.J~ IAlRITT!=II' P!=R'A!~c;,ln~1 nc DRn!=FSc::/nNA/ SCRVIr:F INnll.C::TPlFS IS PROHIBITED
Professional Service Industries, Inc.. 1040-A Shelley Street. Springfield, OR 97477 . Phone 541f746-9649. Fax 541/746-7163
"':;;~;l Information
I.JI::!!.oiWJI. .To Build On
.fl!!ng'. ..... ~. J'bGtIng
Client:
Addre'ss:
Ms. Lauretta Davies
Jerry's Home Improvement
PO Box 2611
Eugene, Oregon 97402
COMPRESSION REPORT
SPRINGFIELD OFFICE
1040 "A Shelley Street
Springfield, Oregon 97477
(541)746-9649 - (541)746-7163 fax
Date: FebruarY.26, 2009 CCB#176269
B.P. No.:-,,-C~::dS9:S
P.O. No.: Z4175LD
Cast By: Glenn Meek Jr
Project No.: 722-90008-18
Proj. Name: Jerry's-Warehouse Renovation
Location: 2525 Olympic Street
Springfield, Oregon -
Placement Data: Materia'l: Concrete Slump (in.): ASTM C143
Slab on grade at pour back at [ruck ramp gridline C.1 at 7.5 to 9, C.9 to D at7.5 to 9 and C.1 Max. Aggr. Size:
Field Test Data
6"
1 1/2"
100 al 7.5 10 7.8
Location Sampled At:
C.9 to 0 a[ 7.510 9
Date Cast: 02/11/09
Ti~~~~~~; IMi~'~VO~~200
Design Strength (psi):
- --',. -
Cylinder No. Test Date
09-0485 2/'18/2009
09-0486
09-0487
09-0488
3/11/2009
3/11/2009
Hold
Date Rec'd: 02/12/09
Weather:
Overcast
required 5,000
Age (days) Field Cure
(days)
7
28
28 --I
H I
Lab Cure
(days)
6
27
27
H
Yardage
2
9/27
Air Content: ASTM C231 L 5.5%
Air Temperature (F): 380
Material Temp. (F): ASTM Cl064 560
Max Temp (F):
Min Temp CF}:
Specimen Size: 6x12
Unit Weight (pcl): ASTM C138
Time Cast: 9:20 AM Curing Conditions:
Additives: AEAlWR
Results Reported To: Contractor
ASTM
Load:
Total:
Supplier:
Knife River
.
Compressive Strength Data ASTM C39
placed 5,000
Diameter or
Dimensions
(Inches)
Cross Sect. Area Cylinder WT. Max. Load (Ibs.) Compo Strength Fracture Type *. Test Time I Capping Method
(s.L) (Ibs.) (psi)
I C617 C1231
28.27 28.30 121,895 4,310 3 3:50 PM X
6.00
H 1 - Cone (both ends) 2 - ConelVerlical Cracks (one end) 3 ~ Columnar 4 - Diagonal wIno cracking at ends 5 _ Side frac ures (at top or boitom)
Remarks:
c: City of Springfield
CIlambers Construction - David Bakke
Robertson Sherwood Architects - Scott Stolarczyk
Metzler Engineering - Scott Metzler
6 - Top fraclures (same as #5 but end of cylinder fs pointed)
ReJ!f~c;:ulIY Submitted,
Pr / ;;;~;;Irvice Industries, Inc.
S(Je Wilder !~
Laboratory Supervisor
~
These results relate only to the specific samples tested and may not be indicative of other locations. This report cannot be reproduced, except ill lull,
without written permission by Professional Service Industries, Inc.