HomeMy WebLinkAboutPermit Building 2009-2-5 Status Issued CITY OF SPRIN\J'l' u<.LD Building/Combination Permit PERMIT NO:. COM2009-00010 ISSUED: 02/05/2009 APPLIED: 01105/2009 EXPIRES: 08/05/2009 VALUE: $ 30,000.00 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line SITE ADDRESS: 326 MAIN ST ASSESSOR'S PARCEL NO.: 1703353106900 Springfield TYPE OF WORK: Commercial Miscellaneous TYPE OF USE: Remodel PROJECT DESCRIPTION: Convert Warehouse portion of building to Photographic Studio Commercial Owner: Address: DNL PROPERTIES LLc 1657 DELROSE AVE SPRINGFIELD OR 97477 I CONTRACTOR INFORMATION I Contractor Type Electrical Mechanical Plumbing Contractor OREGON ELECTRIC SERVICE OWNER OWNER , License 181997 Expiration Date 05/09/2010 Phone 541-343-1681 BUILDING INFORMA !~ON I o # of Stories: Height of Structure Type of Heat: Water Type: Range Type: Energy Path: Sprinkled Building: . Lot Size: Sq Ft 1st Floor: Sq Ft 2nd Floor: Sq Ft Basement: Sq Ft Garage/Carport" Sq Ft Other: . Occupant Load: 1,900 # of Units: Primary Occupancy Group: Secondary Occupancy Group: Primary Construction Type Secondary Construction Type: # of Bedrooms: B VB Yes 19 I DEVELOPMENT INFORMATION' Frontyard Setback: Side 1 Setback: Side 2 Setback: Rearyard Setback: Solar Setbacks: Overlay'Dlst: # Street Trees Rqd: Paved Drive Rqd: % of Lot Coverage: REQUIRED PARKING Total: Handicapped: Compact: I PUBLIC IMPROVEMENTS I Street Improvements: Storm Sewer Available: Special Instruction: Sidewalk Type: Downspouts/Drains: Notes: () r I /lutrlit- III AI(! ~nf2- ~ f-G l-k/ .' ;t'DP 41t-S~ fl PI W1 Page 1 of 3 , Status Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line CITY OF SPRINGFIELD . Building/Combination Permit PERMIT NO: COM2009-00010 ISSUED: 02/05/2009 APPLIED: 01/05/2009 EXPIRES: 08/05/2009 VALUE: $ 30,000.00 I Valuation 'Description I Description Tvpe of Construction Bid Amount Use Bid Amount $ Per Sq Ft or multiplier $1.0.0. Sq uare Footage or Bid Amount 30.,0.0.0..0.0. Fee Description Plan Review Commllnd/Public Plan Review Fire & Life Safety + 12% State Surcharge + 5% Technology Fee 1st Appliance Building Permit Fixture Vent Fan . + 12% State Surcharge + 5% Technology Fee Furnace - Unit Heater Gas Outlets 1-4 . Total Amount Paid Initial Review PubliC Works Review Planning Review Fir'e.Department Review Structural Review Total Value of Project I?~P., Pqifl I Amount Paid Date Paid $20.7.25 1/5/09 $127.54 1/5/0.9 $62.50. 2/5/0.9 $26.04 2/5/0.9 $79.0.0. 2/5/0.9 $318.85 2/5/0.9 $114.0.0. 2/5/0.9 $9.Qo. 2/5/0.9 $2.88 2/26/0.9 $1.20. 2/26/0.9 $17.0.0. 2/26/09 $7.0.0. 2/26/0.9 $972.26 I Plan Reviews I 0.1/08/2009 01/08/2009 APP LLH 0.1/0.8/20.0.9 0.1/0.9/20.0.9 ' APP EW 0.1/0.8/20.0.9 0.1/12/20.09 APP EMM 0.1/08/20.0.9 0.1/26/20.0.9 APP GRG 0.1/0.8/200.9 01/26/200.9 APP cJc Value Date Calculated $30.,0.0.0..0.0. $30.,0.0.0..0.0. 0.1/0.5/20.0.9 Receipt Number 220.0.90.0.0.0.0.0.0.0.0.0.0.0.0.8 220.0.90.0.0.0.0.0.0.0.0.0.0.0.0.8 120.0.90.0.0.0.0.0.0.0.0.0.0.0.80. 120.0.90.0.0.0.0.0.0.0.0.0.0.0.80. 120.0.90.0.0.0.0.0.0.0.0.0.0.0.80. 120.0.90.0.0.0.0.0.0.0.0.0.0.0.80. 120.0.900.00.0.0.0.0.0.0.0.0.80. 120.0.9000.0.0.0.0.0.0.0.0.0.80. 320.0.90.0.0.0.0.0.0.0.0.0.0.128 320.0.90.0.0.0.0.0.0.0.0.0.0.128 320.0.90.0.0.0.0.0.0.0.0.0.0.128 320.0.900.0000000.0.0.128 No new SDc's Photgraphers studio is a permitted use in MUC. See'attached document for Fire Department Plans Review commentl for photography studio conversion. As.noted on plans/conditions letter To Request an inspection call the 24 hour recording at 726~3769. All inspections requested before 7:00 a.m. will be made the same working day, inspections requested after 7:00 a.m. will be made the following work day. Paee 2 of 3 _~~""~lIil!\jl,o.D""::::"~'iit <i" '" .' -:'__~;J';": :'C' CITY OF ~rKl1~GFIELD Building/Combination Permit Status. Issued PERMIT NO: COM2009-00010 ISSUED: 02/0512009 APPLIED: 0110512009 EXPIRES: 08/05/2009 VALUE: $ 30,000.00 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-37691nspection Line I Reouired Insoections I Post and 'Beam: Prior to Iloor insulation or decking. Floor Insulation: Prior to decking. Framing Inspection: Prior to cover and after all rough in inspections have been appruved. Wall Insulation: Prior to cover. Ceiling Insulation: Prior to cover. Underlloor Plumbing: Prior to insulation or decking. Rough Plumbing: Prior to cover and including required testing. Final Plumbing: When all plumbing work is complete. Rougb Electric: Prior to Cover' Final Electric: When all electrical work is complete. Final Building: Afterall required inspections have been requested and approved and the building is complete. , Rough Mechanical: Prior to Cover Final Mechanical: When all mechanical work is complete. By signature, I state and agree, that 1 have carefully examined the completed application and do hereby certify that all information hereon is true and correct, and I further certify that any and all work performed shall be done in accordance with the Ordinances of the City of Springfield and the Laws of the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made of any structure without permission of the Community Services Division, Building Safety. 1 further certify that only contractors and employees who are in compliance with ORS 701.005 will be used on this project. I further agree to ensure that all required inspections are requested at the proper time, that each address is readable from the street, that the permit card is located at the front,of the property, and the approved set of plans will remain on the site at all times during construction. Owner or Contractors Signature Date Paee 3 of 3 225 Fifth Street Springfield, Oregon 97477 541-726-3759 Phone Jpb/Journal Number COM2009-00010 COM2009-000 1 0 COM2009-00010 COM2009-000 1 0 Payments: Type of Payment CreditCard cReceilltl , RECEIPT #: Description Gas Outlets 1-4 Furnace - Unit Heater + 5% Technology Fee + 12% State Surcharge Paid By DAVID B LOVEALL City of Springfield Official Receipt Development Services Department . Public Works Department 3200900000000000128 11:51:03AM Date: 02/26/2009 " Item Total: Amount Due 7.00 17.00 1.20 2.88 $28.08 Check Number Authorization Received By Batch Number Number How Received Amount Paid CJC 00345C In Person Payment Total: $28.08 $28.08 Page 1 of 1 2/26/2009 , Worksheet 4j Project Name: 1 ~7-(. A/.;t1)A!' # <'0,'1''';<- :k>L'r-~~"''lP FURNACE & UNIT HEATERS - GAS & Oil-FIRED Equipment (a) (b) (c) Discussion of equip- Heating ment ratings and equipment definitions Capacity on page 4-19. EQuip, ID Model DesiQnation (Btufhr) AAf~' 7S"'tJ 7~36'X' 1 75:,0iJ I I I I I 1 I I I I, I I I I I I I I I I 1 I I I I I , I I I I I I I I I I I I I I I Required Document- ation Code Required Efficiencies This schedule of equip- ment efficiencies was reformatted from code, Table 13-P. page:L' Minimum Ec (%) (d) Proposed Minimum E, -(%) Compl,ance Schedule (A-E) (e) Minimum AFUE (%) Indicate source of information o GAMA Consumer Directory,.page(s): o Product data (AUachdata furnished by the equipment supplier, I.e., "cut sheets"). ~fEt. S#Gtff Co.mpliance Schedule EauiDment TVDe Gas Fired Warm-Air Furnaces & Combustion Furnace/AC Oil-Fired Warm-Air Furnaces I & Combustion Fl!rnaceJAC I Gas Fired Duct Furnaces I Gas Fired Unit Heaters I Oil-Fired Unit Heaters I A B C D E ", ,I Caoacitv (Btufhr) But not . I over Minimum Efficiencv _ ~C 4., Lt.'_/)ff- 225,000 78% AFUE or 80% Ej' -7 '7 v 6 /V /l'1 ,,. 80% E, I YA"'-",N)t8 5/6 ';L/ 225,000 178% AFUE or 80% Ej. - . I 81%E, ~J' 1'i(4~[.- I I I Over o 225,000 o 225,000 ALL ALL ALL 80% Ec 80%Ee 80%Ee 4-20 Compliance with OSSC, effecl.ive 04/01/07 Form 4a Project Name:1 3-z'-fJ SYSTEMS - GENERAL ~/:.v' #-<N"lPl' 2<Jd 9- 600/0 Applicability Discussion of qualifying ex.ceptions on page 4-25 1. Applicablity (Section 1317) M Is this form required? ' 'f'I Form Required. Complete form if a new HVAC system is being installed, or components of an existing HVAC system are being replaced (I.e" equipment, controls, ductwork, and insulation,) Plans/Specs Show compliance by including a drawing sheet. detail number, specHication section and subparagraph. o Exception. The building or part of the building qualifies for an exception from HVAC code requirements. Applicable code exception is Section 1317,1. Portions of the building that qualify: Area: I Exception 0 -1 0 -2 0-3 Area' I , Area: I Exception 0 -1 0 -2 0-3 Exception 0 -1 0 -2 0-3 o Fonn Not Required. This project does not contain work required to comply with code. ~~. Simple or Complex Systems (Section 1317.9 or 1317.10) II Simple System. Building contains only Simple HVAC System(s). Complete this form (4a) and equipment efficiency worksheets as required. Form 4b is not required. o Complex System, Project includes a Complex System. Complete this form (4a), form 4b and equipment efficiency worksheets as required. 3. Equipment Performance (Section 1317.5) o No New HVAC Equipment. The building plans do not call for new'electrical HVAC equipment, combustion heating equipment, or heai-<>perated cooling equipment. VJ Complies. All new HVAC equipment have efficiencies not less than those required by code, The following equipment efficiency worksheets are attached: o -4a 0 -4b 0 -4c 0 -4d 0 -4e 0 -4f 0 -4g 0 -4h . 0 -4i 0-4j 4. Duct Insulation and Sealing (Sections 1317.7 & 1317.8) J~ No Ducts. The building plans and specifications do not call for new HVAC ducts or plenums. )Q Complies. The plans and specifications call for all air-handling ducts and plenums to be insulated , and sealed as required by Sections 1317.7 &1317.8. 5. Distribution Transformers (Section' 1316.1) \~ No Dis~ribution Transformers. The plans/specs do not call for new distribution transformers. 'Ei Complies. All new distribution transformers comply with efficiency, testing, and labeling requirements of Section 1316.1.1. . o Exception. The project qualifies for an exception per Section 1316.1.1, Exceptiion: 0-1 0-2 0-3 0-4 0-5 0-6 0-7 0-8 0-9 0-10 0-11 0-12 0-13 0-14 Attach relevant documentation for appropriate exception. The plans/specs show compliimce in the. following locations: J j 4-1 j Compliance with OSSC, effective 04101/07 Form 4a Project Nam'e:1 SYSTEMS - GENERAL page:1 Part 2 of6 " 6. HVAC Controls (Section 1317.41 "J 6.1 System Thermostat/Zone Controls (Section 1317.4.1) , 'IJ Complies. All new HVAC systems include at least one temperature control device responding to temperatures within the zones. o Exception. HVAC system qualifies for an exception from zone control requirements, The applicable code exception is Section 13t7.4.2, Exception 0 -1 0-2 I Portions of the building that qualify: The plans/soecs show comoliance in the followinq locations: I , 6.2 Off-hour Controls - Auto Setback or Shutdown (Section 1317.4.3) 'fi Complies. Systems must have at least one of the following features:. a Control Setback Complies. Each system is equipped with automatic control capable of reducing energy through control setback during periods of non-use or alternate use of spaces o Equipment Shutdown Complies. Each system is equipped with controls capable of reducing , energy use through automatic shutdown during periods of non-use or alternate use of spaces. o HVAC systems with equipment shutdown are equipped with at least one of the following: o Progra'mmable con1rols (1317.4.3.1 (1)) o Occupant sensor (1317.4.3.1 (2)) o Interlocked to a security system (1317.4.3.1 (3)) o Manually activated timers with 2-hour operation max (1317.4.3.1 (4)) o Exception. The building qualifies for an exception to the requirement for automatic setback or shutdown'controls. The applicable code exception is Section 1317.4.3 Exception 0 -1 0-2 The plans/specs show compliance in the following locations: I 6.3 Control Capabilities (Sec. 1317.4.2.1) , lfJ Complies. Zone thermostats are capable of being set to the temperatures described in Sec. 1317.4.2.1. Where used to control both heating and cooling, zone controls shall be capable of providing a temperature range or deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. o Exception. The building qualifies for an exception to the deadband requirements. The applicable code exception is Section 1317.4.2.1 Exception 0 -1 0-2 Portions of the building that qualify: I The plans/specs show compliance in the following locations: I '46.4 Optimum Start Controls (Section 1317.4.3.2) .". Complies. Separate HVAC systems have controls capable of varying start-up time of system to just meet temperature set point at time of occupancy. o Exception. HVAC systems have a design supply air capacity not exceeding 10,000 elm. .The plans/specs show comoliance in. the fOllowinq locations: I - ~ 6.5 Heat Pump Controls (Section 1317.4.4) No Heat Pump. The plans/specs do not call for a new heat pump , Complies. All new heat pumps equipped with supplementary heaters are controlled to minimize the use of supplemental heat as defined in Section 1317.4.4. The plans/specs show compliance in )he following locations: I 4-2 Compliance with OSSC, effective 04/01/07 Form 4a' Project Name: I I page:1 Part 30f6 SYSTEMS - GENERAL 7. Economizer Cooling (Section 1317.3) 'Ii No Cooling. The ,building plans do not call for a new fan system with mechanical cooling. a Complies. Each new fan system has an air economizer capable of modulating outside-air and return-air dampers to provide up to 100 percent of the design supply air as outside air. o Exception At least one new fan sysiem qualifies for an exception, The applicable code exception is Section 1317.3, Exception 0 -1 0 -2 0 -3 0 -4 0 -5 0 -6 0-7 If Exception 3 is selected complete the following: (a) To1ai'cooling capacity of exempt units (Btu/hr) I (b) Total installed building cooling capacity (Btu/hr) I I o Complies. Sum of exempt units rated at less than 54,000 Btu/hr is <240,000 or alb < 0.10 (10% of total building cooling capacity), Unit Identifier of exempt units: I The plans/specs show comoliance in the followinq locations: I ' 8. Economizer Pressure Relief & Integration (Section 1317.3.1 and 1317.3.21 'jj No Economizers Required. Project does not contain a new fan system requiring economizers, o Overpressurization Complies. The drawings specifically identify a pressure relief mechanism for each fan system that will relieve the extra air introduced by the economizer. o Integration Complies. Economizer is capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. o Exception. The applicable exception is Section 1317.3.2, Exception 0 -1 0-2 The plans/specs show compliance in the following locations: I ,9. Hot Gas Bypass (Section 1317.5) 'Jd' No Hot Gas Bypass ' tl Complies. See allowable amount of hot gas bypass as a percentage of total cooling capacity in , table below.' UnitlD Rated CoolinQ CaoacllY Hot Gas Bvoass Caoacl~ I I I >240,000 Btu/hr 25% I o Exception. Unitary packaged system with cooling capacity no greater than 90,000 Btu/h Allowable Hot Gas Bypass Rated Cooling Capacity Max Hot Gas Bypass S240,000 Btu/hr 50% 4-3 Compliance with osse, effective 04101/07 ~t J~1\ Form 4a Project Nam~:1 SYSTEMS - GENERAL page:1 Part 4 of6 10. Shutoff Dampers (1317.4.3.3) D Not Required. Shutoff dampers are not required on this project. "\0 Complies. Each outdoor air supply &. exhaust system shall be equipped with motorized dampers D Exception. The building qualifies for an exception to the motorized damper requirement. The applic-able code exception is Section 1317.4.3.3 Exception D -1 D -2 D -3 0 -4 D-5 The plans/soecs show comoliancein the followina locations: I 10.1. Shutoff Damper Controls (Section 1317.4.3.3.1) . mplies. Outdoor air supply and exhaust systems shall be provided dampers that automatically shut en systems or spaces served are not in use or during building warm-up, cooldown, or setback. D Complies. S . and shaft vents are capable of being automatically closed during normal building operaiion and int cked to open as required by fire and smoke detection systems. The plans/specs show mpliance in the following locations: I 10.2. Motorized Damper Leakage (1317.4.3.3.2) 'Complies. Motorized outdoor air supply and exhaust air dampers have a maximum leakage rate 4 cfmlft2 at 1.0 in w,g. when tested in accordance with AMCA Standard 500-1998. D Exce 'on. Packaged HVAC equipment may have maximum leakage rate of 20 cfmlft2 at 1.0 in w.g. whe ested in accordance with AMCA Standard 500-1998. ' , The plans/sp s show compliance in the following locations: I , ~ 1. Piping Insulation (Section: 1314) D New Piping. The building plans and specifications do not callIor new piping serving a . hea or cooling system or part of a circulating service water heating system. Complie All new piping serving a heating or cooling system or part of a circulating service water heatin system complies with the requirements of the Code, Section 1314.1. Exception. Ne iping qualifies for exception: Section 1314.1, Exception D -1 D-2 ,,, II. .~. I .' 12. Occupancy Ventilation4,/O;L,e'S/,<J tG / MA',a-;t.Iba.-st: A-tJr /~(I'/<O. D Complies. Mechanical ventilation systems provide the required amount of ventilation specified in Chapter 4 of the Oregon Mechanical Specialty Code. D Complies. Natural ventilation systems provide required amount of ventilation as certified by a reg-istered architect or engineer as specified by Section1203.4.1, Exception. Attach worksheet The plans/specs show compliance inl the following locations: ; The plans/specs show compliance on the following pages: 4-4 CompUance with OSSC, effective 04/01/07 Form 4a Project Name: I SYSTEMS - GENERAL pagel Part 5 of6 13. High Occupancy Ventilation (Section 1317.2.21 o Complies. HVAC systems with ventilation air capacities of 1 ,500 CFM or greater that serve areas having an average occupant load of 20 square feet per person or less from Table 1004.1.2 have a means to automatically reduce outside air intake. Identify applicable systems: I Plans/specs indicate where eouioment (I.e. carbon dioxide sensor) and seouence is specified: I U Exception. HVAC systems are equipped with an energy recovery device wrth at least 50% V recovery effectiveness. >>'l No High Occupancy Systems. Project does not contain an HVAC system as described above. . . J.4. Exhaust Air Heat Recovery (Section 1318.3) }ltNot Regulated. HVAC system does not have: 1) design supply air cap. of ~10,000 cfm, and 2) min. outside air supply ~70%, and 3) at least 1 exhaust fan rated at 75% of min outside air o Complies. Heat recovery system increases outside air temperature by 20"F (Climte Zone 1) or 30"F (Zone 2) and has provision toprovide"bypass during air economizer mode. D Exception. An HVAC system qualifies for an exception to this requirement. Applicable exception from Section 1318.3 Exception 0 -1 0 -2 D -3' D -4 0 -5 0 -6 0-7 The plans/specs show compliance in the following I locations: ~.J. . no , " I ,.15. Large Volume Fan Systems (Section 1318.4.2.41 .1&1 Not Regulated. The building plans or specifications do not call for fan systems over 15,000 ' CFM that serve a single zone and function for the purpose of temperature control. o Complies. Fan systems are equipped with variable frequency drive or two speed motor to reduce airflow as required by Section 1318.4.2.3. The plans/specs show compliance in the following locations: .16. Variable Speed Drives (Section 1317.10.3.1) o Not Regulated. The building plans or specifications do not call for fan and pump motors 10 Whorsepower and greater that serve variable-flow air or liquid systems. ~Complies. All fan and pump motors 10 hp and greater which serve variable-flow air or liquid systems are controlled by a variable-speed drive. D Exception. The building qualifies for an exception to the variable-speed drive requirement. Portions'ofthe building that qualify: I Applicable' code exception is Section 1317.10.3.1, Exception The plans/specs show compliance in the following I locations: tJ.7. Service Water Heating (Sec. 1315) 7 ~ No New Water Heating. The building plans and specifications do not call for new water 'heaters, hot water storage tanks or service hot water distribution systems. . D Complies. All new water heaters, hot water storage tanks or service hot water distribution systems comply with the requirements of the Section 1315.. D Exception. The applicable code exception is Section: r I Exception: I Portions of the building that qualify: I The plans/specs show compliance in the following locations: I - ,14-5 Compliance with OSSC, effective 04101107 ... Form 4a Project Name: I page:1 Part 6 of 6 SYSTEMS - GENERAL " ..p. Swimming Pools, Spas and Hot Tubs (Section 1315.5) ~ No New Pools. The building plans and specifications do not call for new, swimming pools, spas or hot tubs. o On/Off Controls Complies. Spa and hot tub heaters are equipped with a readily accessible ON/OFF switch as required by Section 1315.5.1, o Ventilation Controls Complies. Pool ventilation system is controlled based on humidity. o Cover Complies. All heated pools, hot tubs and spas are equipped with a cover. o Heat Recovery Complies. Pools, Spas, and hot tubs, over 200 ft2 utilize recovered heat as required by Section 1315.5.3, o Exception. Heat recovery is not necessary as pool is heated by renewable energy or waste heat recovery sources capable of providing at least 70 percent of the heating energy required over an operating season, . ,,, .JP. Fume Hoods (Section 1317.2.1.) ~ No Fume Hoods. The building plans do not call for fume hood systems that have a total exhaust rate greater than 15,000 clm. o Complies. Fume hood systems have at least one ot'the following features: o Variable air volume hood exhaust and room supply systems capable of reducing exhaust and makeup air volume to 50% or less of design values. o Direct makeup (auxiliary) air supply equal to at least 75% of the exhaust rate, heated no warmer than 2" F below room set point, cooled no cooler than 3" F above room set point, no humidification added, and no simultaneous heating. and cooling used for dehumidification control. o Heat recovery systems to precondition makeup air from fume hood exhaust in accordance with 1318:3 - Exhaust Air Energy Recovery, without using any exception. The plans/specs show compliance in the following locations: I . ,,' . ..3fJ. Parking Garage Ventilation (Section 1317.2.3) Jl No Enclosed Garages. The building plans and specifications do not call for enclosed Group S-2 , parking garages with a ventilation exhaust rate greater than 30,000 CFM. o Complies. The plans and specifications call for carbon monoxide sensing devices as required by Section 1317.2.3. o Exception. Open parking garages. I 21. Kitchen Hoods (Section 1317.11) )Q Not Regulated. The plans/specs do not call for any new kitchen hoods with exhaust capacity , greater than 5,000 cfm each, . o Complies. All new kitchen hoods with a total exhaust capacity greater than 5,000 cfm have at least 50 percent of the required Illakeup air; (a) unheated or heated to no more than 60"F; and (b) uncooled or evaporatively cooled. The plans/specs show compliance in the;following locations: I l.. .., 22. Outside Heating Systems (Section,1317.12) 11 No Outside Heating Systems. The plans/specs do not call for new permanently installed heating systems outside the building. . , o Complies. All new permanently installed outside heating systems are radiant gas fired systems controlled by an occupancy sensor or timer switch as required by Section 1317.12. 4-6 Compliance with asse, effective 04101/07