HomeMy WebLinkAboutPermit Building 2001-2-20
.
I Job# 00-00908-01 I
.-
Page 1 of4
TRANS#:01-0004481
DATE:FEB 20 2001
AMT RECD:2 $ 16.50
CHANGE:
CASHIER:061
CITY OF SPRINGFIELD, OREGON
RESIDENTIAL PERMIT
City Of Springfield
Community Services Division
Building Safety
Job Number: 00-00908-01
225 North Fifth Street
Springfield, OR 97477
Office: 726-3759
Inspection Line: 726-3769
Location Of Proposed Site: 825 McKenzie Crest Dr Spr
Assessors Map#: 17032342
Lot: 100 Block: Addition:
Tax Lot #: 01000
Subdivision: River Glen
Owner:
Anslow & Degeneault Inc
1953 Garden Avenue
Phone Number: 503-484-0070
City/State/Zip: Eugene, OR 97403
New Value: $286,775
Address:
Scope Of Work: Single Family Residence
plans submitted for quickstart
Contractor Type
General Contr
Engineer
Contractor Registration #
Anslow & Degeneault Inc 49169
1953 Garden Avenue, Eugene, OR 97403
Hal Pfeiffer
40 W. 17th, Eugene 0, OR
Expiration Date
10/16/00
Phone
503-484-0070
541-683-4257
Verify Ground Rod
Footing
Foundation
Post and Beam
Floor Insulation
Ceiling Insulation
Shear Wall Nailing
Framing
Wall Insulation
Drywall
Hold Downs Installed
Final Building
Office Use
Land Use: Single Family Dwelling # Of Buildings: 1
Zoning Co~e: LDR ATI<:; . -;- G" . ~ .~::- ~C?cupancy;~~o.~.~:} Dwelling
Bedrooms. 3 f II I ~- " ,..' Heat Source.~ I ,(', ly
Q O\iJI'l',"";......W..j,H.:..~ ". '" v._ - ".
Range: 1\1 t'" , .., '11Sq. Footage: ,,3907. 1
n iIICL{I\JfIVdllh.,I. H',_":' ..-..~~ " _.
in OAR !-I:>2-UU'I-UU1 u ,nrolJQn u/'\('\ '10"'-VV"
To request an inspection call the 24 hour recording at 726-3?~~:(AI~il).~P'lqtio~s:re,ql!estEl.d'bef<ire 7>:003 by
a.m. will be made the same working day, inspections requestect'''afterl'g7:00'a:m.twill be made the', following
. Ci::llln .1I0.....;UI ...... ,.'............. ."- ~- -,"' .
working day. b ,.. ., "J ' .'!':".,"otificatlon
nuitl dr IVI ..J1.,"~\J''''''J .- ,1.
Required InspectionsC~:.._~:_ ~ _~_"") )".dl
I Building I
-Install ground rod at footing, and call for inspection in conjuction with footing and/or foundation i
-After trenches are excavated.
-After forms are erected but prior to concrete placement.
- Prior to floor insulation or decking.
- Prior to decking. NOTICE'
- Pnor to cover. .
- Before covering sheathing with finish-matefiiilS'.'VIIT SHALL EXPIRE IFTHE WORK
- Prior to cover. AUTHORIZED UNDER THIS PERMIT IS NOT
: ~;:~; :~ ~~~~~. COMMENCED OR IS ABANDONED FOR
ANY 180 DAY PERIOD.
- When all required inspections have been approved and the building is complete.
Quad Area:
# Of Units:
Constr. Type:
Water Heater:
3RNC
1
(VN) Wood Frame
Street Improvement: Fully Improved
Curb Cut?0 Improvement Agr.?D
San Sewer Depth (Ft): 6 8
Storm Sewer Available? 0
Special Req.:
Security Required:
Bond Begin DateTime: 00/00/00 00:00 AM
Special Instructions:
Other Utilities:
Project Supervisor:
Temporary Power
Underground Electrical
Rough Electrical
Electrical Service
Low Voltage
Final Electrical
Underfloor Plumbing
Underfloor Drain
Rough Plumbing
Shower Pan
Water Line
Sanitary Sewer Line
Storm Sewer Line
Perimeter Foundation
Drains
Backflow Device
Final Plumbing
Underfloor Mechanical
Rough Gas
Rough Mechanical
Gas Service
Final Gas
Final Mechanical
Curbcut
Sidewalk
.
.
I Job# 00-00908-01 I
Page 2 of4
Required Inspections
I Electrical I
-Approval required prior to SUB energizing pole.
- Prior to cover.
- Prior to cover.
-Must be approved to obtain permanent power.
- When all electrical work is complete.
I Plumbing
- Prior to insulation or decking.
- Prior to cover or placement of concrete.
- Prior to cover.
- Prior to filling trench.
- Prior to filling trench.
- Prior to filling trench.
-After gravel and filter cloth is installed, but prior to backfill.
-After device is installed but before backfilling trench.
-When all plumbing work is complete.
I Mechanical
-Prior to insulation or decking.
- Prior to cover.
-After line is installed and line has been connected to a minimum of one appliance. Pressure te,
- When all gas work is complete.
- When all mechanical work is complete.
I Public Works I
-After forms are ereceted but prior to placement of concrete.
Sidewalk Type:
Additional ROW?
Size Of Line (in):
Downspouts/Drains:
Enchroachment Permit:
San Sewer Tee (in):
Bond End DateTime:
Setback - 5'
o
8
To Curb and Gutter
6
00/00/00 00:00 AM
Types Of Warning Devices Reqd.
Zoning: LDR
FloodPlain? 0 Wetlands? D
Journal numbers
1: 2:
Comments:
Planner: AI Ward
Urban Growth Boundary?D
Quantity Of Fill:
Supplier:
Drainage:
Floodway FEMA: n/a
.
I Job# 00-00908-01
Overlay District:
# of Street Trees:
.
3:
Additional Requirements:
Glenwood Area? 0 Required Attachments:
Source Locn:
Material:
Construction Types:(VN) Wood Frame
Occupancy Groups: Dwelling
# Of Buildings: 1
# Of Bedrooms: 3
Handicap Access? D
rArea (Sq. Feet)
I Main: 3907 AccessoryBOO
Fee
Residential Plan Check
Total Plan Check
Building Permit
State Surcharge For Building Permit
Building Administrative Fee
Total Building
Wiring Footage 1,000 Sq Ft or Less
Wiring Footage Each Add'l 500 Sq Ft
State Surcharge - Electrical
Administrative Fee - Electrical
Total Electrical
Minimum Plumbing Permit Fee
Minimum Plumbing Permit Fee
State Surcharge - Plumbing
State Surcharge - Plumbing
Four or More Bathrooms
Backflow Prevention Device
Administrative Fee - Plumbing
Administrative Fee - Plumbing
Total Plumbing
Hood and Exhaust
One to Four Outlets
Minimum Mechanical Permit
Administrative Fee - Mechanical
Flood Plain FEMA: n/a
Page 3 of 4
Land Use: Single Family Dwelling
Pave Driveway? 0
Accessory Structure
# Of Stories: 2 Height (feet): 28
Current Units:O Proposed Units:l
Census Code: Does not apply
Total:4707
Paid On Receipt#
Plan Check
06/09/2000 2089
Building
09/28/2000 3333
09/28/2000 3333
09/28/2000 3333
Electrical
09/28/2000 3394
09/28/2000 3394
09/28/2000 3394
09/28/2000 3394
Plumbing
09/28/2000 3333
02/20/2001 4481
09/28/2000 3333
02/20/2001 4481
09/28/2000 3333
02/20/2001 4481
09/28/2000 3333
02/20/2001 4481
Mechanical
09/28/2000 3333
09/28/2000 3333
09/28/2000 3333
09/28/2000 3333
Value/Quantity
Fee Amount
286,755
$554.94
$554.94
286,775
$853.75
$59.76
$25.61
$939.12
1
6
$85.00
$90.00
$12.25
$5.25
$192.50
1
1
$.00
$5.00
$13.48
$1.05
$192.50
$10.00
$5.78
$.45
$228.26
1
1
$4.50
$2.00
$.00
$1.05
.
.
Fee
Less than 100,000 BTU
Vent Fan to One Duct
Gas Fireplace
Dryer Vent
Mechanical Issuance
State Surcharge - Mechanical
Total Mechanical
New Sidewalk
New Curbcut
Total Public Works
Residential - Single Family - Storm
Sanitary Sewer
Residential Transportation
Residential Sanitary MWMC
Residential Improvement MWMC
MWMC Administrative Fee
SDC Administrative Fee
Property Annexed 1990
Total System Development
S.F. Residence - Wi llama lane
Total Willamalane SDC
Grand Total
Plan Check Type
Checked By
Initial Review-Res
Wendy Stanley
Steve Templin
AlWard
Engineering-Res
Planning-Res
Job# 00-00908-01
. Page 4 of 4
Value/Quantity Fee Amount
'I
1 $6.00
5 $15.00
1 $4.50
1 $3.00
$10.00
$2.45
$48.50
140 $63.00
1 $60.00
$123.00
6,095 $1,414.04
39 $1,882.53
1 $491.60
1 $242.76
1 $22.05
1 $10.00
$201.84
15 $-26.25
$4,238.57
1 $1,000.00
$1,000.00
$7,324.89
Paid On Receipt#
r Mechanical
09/28/2000 .3333
09/28/2000 3333
09/28/2000 3333
09/28/2000 3333
09/28/2000 3333
09/28/2000 3333
Public Works
09/28/2000 3333
09/28/2000 3333
System Development
09/28/2000 3333
09/28/2000 3333
09/28/2000 3333
09/28/2000 3333
09/28/2000 3333
09/28/2000 3333
09/28/2000 3333
09/28/2000 3333
Willamalane SDC
09/28/2000 3333
Date Completed
Comment
06/13/2000
06/14/2000
06/15/2000
Structural-Res Wendy Stanley 06/23/2000 engineered plan
By signature, I state and agree, that I have carefully examined the completed application and do
hereby certify that all information hereon is true and correct, and I further certify that any and all work
performed shall be done in accordance with the Ordinances of the City of Springfield and the Laws of
the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made
of any structure without permission of the Community Services Division, Building Safety. I further
certify that only contractors and employees who are in compliance with ORS 701.055 will be used on
this project.
I further agree to ensure that all required inspections are requested at the proper time, that each
address is readable from the street, that the permit card is located at the front of the property, and the
approved set of plans w~1femain on the site at all times during construction.
Lj Jall-uA bd;?~/ULLII $_"':'?"J_O/
Signature 0