Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 1996-4-16 jj}B~6b<-('?~ Ap",'-1-/-96 09:42A Morar Engineering .1 )484-6859 P.02 1:.0. [;.'))( 139 . 124") PfARL STREET EUGENE, OREGON ~;744C1 PHONE \~OJI 484.9080. FAX (503) 484.6859 STRUCTURAL EJUILDING DE!:IGN D FIRE PROTEClic'ti CODE CONSULTANT. PLAN CHECKlr~G CONSTRUCTION lNSFECTIOI~ MORTIER t.::NGINEERING, P.c. .' _...._~_ ..___r_' April 16, 1.996 ~..... ~ Dana Evan.. 1474 Goodpasture Island Rd. f:ugene, OR 97401 RE : lillLMO\l"ke.t._~c::t-. W.O. j/B970-RDR SDr inaf iel.;L:-...F-oundat12lLS 1.a b In s peg.tt!.2Il As you requested, an inspection was adequacy of the existing patio slab and wall load from the proposed addition. performed to determine the slab edge to support roof and The approxlmately 20-25 year old slab on grade is void of any v.i l1u'1l structura 1 detects with little or no cracking and no evidence- ot heaving due to expansive soils. The approximately B inch deep by 10 inch (mllxlmuro) wide unreinforced expanded slab edge shows no struct.ura 1 defect. Al though the bottom of the footing is above the code requ.i red frost depth, no evidence of damage due to frost heave was observed. Thp. mAximum calculated soil pres'Hlr.p. based upon an average 8 inch wldr.h 1s 650 psf. The allowable soil pressure for this type of 9011 is 1000 psf. Based on observations at the site and 60il pres~ure calcul ati ons, the slab and slab edge 1.s adequate to support the proposed roof and wall vertical load. r hope you find this report adequate for your purposes at this tim". Please contact me if you have further questions. Thank you for thi f.: opportunity to be of service. Very truly yours, 1/11j., . 1v 'EXPIRES: ~o;"'., ~ f Owen Grover, P.E. OLG/re