Loading...
HomeMy WebLinkAboutPermit Signage 1984-5-22 r_-. . ."~ ." ~. ~~ ,- .. ,- city of springfield 225 n. 5th street SPRINGFIELD .. . . .~ ~. INFORMATION: 726-3753 INSPEC'TIONS: 726-3769 SIGN PERMIT APPLICATION A, LOCATION OF SIGN (ADDRESS) ADDRESS \ '2., \0 VV\.o..y-Ke~ ~-+. LECAL DESCRIPTION I, ^ '1. , ~ -7,::l, ~ -e- <0 (2..5 -e... w\ -(!:IV- V' ~ c:, \ ~ t n IN\.. Q....-\<:' -e + <::; + OIINER OF SIGN (IF OTHER TllAN PROPERTY OWNER) C. "" '0.. (2.. ~e ~ \ ~ \. 0 VV\.'t..-Ke+ ~+ NAME OF BUSINESS, FIRM, ETC, ("' \" a" It-\ec-; SP. O~~ TA.~ LOT'!: (') Q .J, ~l) ,PHONE ('17 -l-t '2. '-{ b ZIP Q. r'i 7 7 ';::'L~ ~ s ~ea. ~ +':\ :J;IA c.. , , PHONE -, '-\: (n ~:s '2.:'7' (') E (\ 'lo; ~eo.~~:iuSWE5S f-. Po I t::.c:;.1k~~' 'OllNER OR PROPERTY ADDRESS -. B. TYPE OF WORK: ~ERF.CT _ALTER _RELOCATE OTIlER C, STRUCTURAL TYPE OF SIGN:. _HALL -LFREESTANDING ROOF _PROJECTING _MARqUEE UNDER l1AROUEE - . OTHER [). USE AND CP~RACTER OF SIGN: _IDENTITY _INCIDENTAL ~DOUBLE FACE _SINGLE FACE -,'!ULTI-FACE _P~ER BOARD _BILLBOARD i i i i ; E, VENDORS, CONTRACTORS: SIGN ERECTOR , c,~ \--E . PIICNI::_ .f.DDP.ESS CITY LICENSE llU!1BER ~- SIGN l1ANUFACTURER (IF OT~R THAN ERECTOR) . C a.. <; C. a. A. e. ~ '2, ?, (r:> \.0 ~ c:::... --\-t=' \1"" ~~ - PEONE . Go Vj'PlAO_ I nQ.~~I'''' F. DIHENSIONS. lllSTALLATION & CONSTRUCTIOIl ' G, EXISTING SIGNS ~ LJI..,II TOTAL HEIGHT ABOVE GRADE ., '" ARE THERE ANY EXISTHlG f.IGNS?' YES ':""NO VERTICAL DIMENSION OF SIGN :l..l" 11UHBE~ SIZE IN SO.FTG, HORIZONTAL WIDTH OF SIGN 5' I ALL EXISTING SIGNS I DHlENSION FROM GRADE TO l FOR EUSINESS, ETC, BOTTOM OF SIGN :J..' i&, I \, ZIr_ ADDRESS EXP. DATr. , <0 - Sots f\..S_ o 0-<? - t-{q Cnl-{ DOES SICN PROJECT BEYOND PROPERTY LINE? ___YES IF YES, DIMENSION BEYOND PROPERTY LINE NOTE: IF PROJECTIOll IS llORE TllAN 12" OVER PUBLIC PROPERTY TEE SIGN ERECTOR lruST FILE WITH THE BUILDING DIVISION COPIES OF HIS/HER LIABILITY AND PROP- ERTY DAllAGE INSURANCE POLICIES, -p-NO H, HI~L SIGN HAVE ELECTRICAL lURING? \1\ 7) IF YES. \IllICE APPLY? ELECTRICAL SIGN __ILLUMINATED (INDIP~CTLY LIGHTED) ELECTRICAL COIlTRACTOr.. ADDRESS LISC. NUMBER ISLtJ ' If / ;......t THICKNESS OR DEPTH ," P!,CNC K'VALUE OF SIGN: !f. :2,C)(\, ()C) J, SITE INFOPllATIOll (LAND USF.) -- EXISTING USE OF BUILDING ,OR LAND (0R ~ST UrE ,IF VACANT) o k.Q. t< e -€:. '-' \ \c\ ~It\..c, I \I'<?v \Q.cLV\ c -e. S C>.. \~ 1'2... "E'o.J ~ c;. +6... ~ S Q \ \!?"S ~INDOOR BUSINESS _OUTDOO:l. l,fERCHANDISING PROPOSED USE OF BUILDING OR LAND, <SOL W\.p CA.'? (Pt- ~I{P I. DESCRIBE TYPE OR ~ATERIALS SIGN IS So-v-4C~t~~ 'u...>OO~ L'I HAVE CAREFULLY E~IINED the completed application for permit and do hereby certify that all information is true and correct, and I further certify that all work performed shall be done in accordance with the Springfield Sign Ordinance, the Uniform Sign Code as adopted by the City of Soringfield.and all other Ordinances of the City of SprinRfield and the laws of the State of Oregon per"caining to t~le worl~ ocscribed ilt:.Lc.1.n. I further certi.!'y that: MY :::!.r,n Co~tractor Li- cense with the City of Sprin~field is in full force and effect as required by Sprinp.field Codes 8-2-6(3) and 9-7-20(2}, I will request all required sign insoections listed on the approved permit. NAME (PLEASE PRINT) C t""o.... R.\eS ~,E \ \ \ 'c:; SIGNATURE ~)f\.....A (\ ()Of\{ r'i--(!t2. _' . DATE r:::;/22.J ~4 I I . PLEASE READ . , I 1) SeDarate 5i2n Aoolication: A separate application 1s required for each separate sign as defined 1n the Slgn Code. Electrical: Any permit issued under this application will include wiring in or on sign structure, the supply wires for connection must be covered on an electrical permit. Electrical connection must be made only by a State Licensed Electrical Contractor. Illuminated signs (both internally and externally) must conform to Sections 9-7-4 (4) & (5) and 9-7-18 of the Springfield Sign Or- dinance. 2) 3) Plans Reouired: This application is to be submitted with two complete sets of plans showing di- mensions and height of sign: advertising message on signj location of sign on property with di- mensions to property lines, structural details of support framing, bracing and footinES; materials of construction for sign and ~isn structure; electrical equipment and lighting; size and location of existing signs on property for the same busienss, all as required to determin~ com9liance with the Springfield Sign Ordinance (Article 7 of the Springfield City Code), Also,. show the follow- ing informacion on the plot plan (plan showing property lines and location of signs): a) Show the location of all existing sign(s) as well as proposed sign(s), b) Show the length of the SCreet frontage taken up by the business or building. For wall signs, show the lengch of the building frontage, c) Show the location of entrances open to the public and driveways. When required, because of design, size, etc., engineered drawings and calculations must be pre- pared by a licensed engineer or shall conform to design standards on file at the Building Divi- sion Office, Plans of insufficient clarity or detail will be returned to the applicant with no permit being issued, Signs must meet corner vision clearance requirements as described in Figure 9 of the Springfield Comprehensive Zoning Code. NOTE: No sign may be erecced which is less than 12 feet horizontally or vertically from. overhead electrical conductors in excess of 750 volts, or less than 5 feet in any direction froc overhead electrical lines which are energized at less than 750 volts. If a sign is not installed within 60 days after the date of issue of this permit, the permit shall be void.. .. Insoections: / 4) 5) 6) 7) 8) 9) a) Site Inspection - to be made before the sign is placed. Usually, the Footing Insoection (it applicable) may be made at the same time as the Site Inspection. The rooting Inspec- tion is to be made after hole(s) is e~avateci, but prior to the placement of c~ncr~te. b) Final Insoection,- to be made upon completio~ of all work, c) ~lectrical - all electrical signs 'must be inspected for electrical hook up after the sign 1s erecCed and before the sign is turned on, CALL rOR THE REQUIRED INSPECTIONS ON THE'24 HOUR INSPECTION LINE AT 726-3769 FOR UFF1CB USE ONLY SIGN DISTRICT;ef'P""'. ZONE DISTRICT TOTAL SQUARE FOOTAGE OF SIGN A1'. ~ REOUxRED INSPECTIONS: ~ITE/LOCATION ;PH JOB f} RL/()?/1/ SIGN PERMIT FEE: it/(),rFlJ _ELECTRICAL OTHER FOOTING ~NAL c OR METHOD OF ATTACHMENT ELECTRICAL PERMIT FEE: 47. STATE SURCIlARGE: C TOTAL: 1/ d, cZ> DATE ,C; - ;) Cj' -N RECEIPT 10 ;;L %8 I ~1 nrlAv , . , i CLERK I I SPECIAL CONDITIONS TO BE SATISFIED BEFORE ERECTION OF SIGN: ADDITIONAL INFORMATION NEEDED BEFORE PERMIT MAY BE ISSUED: APPROVED BY: ~ SPRINGFIELD SIGN ORDINANCE DATE .:r-Z'-9 c/ / SECTION: 7-~ . . 1310 ~Iarket Street