Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 2009-2-19 ~fEI . Page 1 of 1 Gc.v~ . ,;caJ & Construction Sef\.ires Daily Field Report . 1I).'ltflrt;.lf..';':;'IIIIII_ Client: Mr. Charlie McClain Mcintyre Construction PO Box 2523 Eugene, Oregon 97402 Project: Enterprise Rent-A-Car 4396 Main Street Springfield, Oregon Date: Project No,: Report No.: Inspector: 10 No.: 02-19-09 2097017 E-22423 D. Delatte 1080867-84 ICC Inspection of: Masonry Contractor: Mcintyre Construction Weather: Overcast BP No.: C8-00589 Continuous Inspection: 0 Periodic Inspection: 0 Performed inspection on reinforcing steel for 8" CMU walls, perimeter walls and one (1) interior wall north side of carwash area (8' to 12'). Reinforcing steel was checked for . grade, size, lap, placement and clearance,. where applicable. Reinforced cells appeared to be free and clean of excessive mortar projections. Observed the placement of 10.5 yards of 7 sk grout (mix 7-GNO) from Knife River for walls noted above. Grout was placed by pump and mechanically consolidated. Walls were grouted solid. Brent (Hap's Masonry) was asked to notify our office when additional services are needed. . To the best of our knowledge, the work inspected was in accordance with plans dated 04-10-08 and applicable workmanship provisions of the I.B.C., except if noted above. Reviewed BY:d ~1f;,-tcr Michae! L. Meyer Technical Manager c: City of Springfield MLM:sc This report and/or enclosed test data is the confidential property of the client to lNhom it is addressed and pertains to the specific process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part thereof be disclosed without FEI Testing & Inspection, lnc.'s written authorization. 750 NN CaneII Avenue' CavaIIls, Oeg:n 97330, phone (541) 757-4698' fax (541) 757-2991 29540 B Airport Road . Eugene, Oeg:n 97402 . phme (541)684-3849 . fax (541) 684J851 63050 Corporate Place, Su~e 2' Bend, Oregon 97701 . phone (541) 382-4844 . fax (541) 382-4846 RECEIVED FER 2 6 ?nnq Sf;l Page 1 of 1 GcvW ,,1ia31 & Construction Servires Daily Field Report . 11;"11Im';.I~.":iI:'.IIIJI.m. Client: Mr. Charlie McClain Mcintyre Construction PO Box 2523 Eugene, Oregon 97402 Project: Enterprise Rent-A-Car 4396 Main Street Springfield, Oregon Date: Project No.: Report No.: Inspector: 10 No.: 02-17-09 2097017 E-22412 D. Delatte 1 080867-84 ICC Inspection of: Masonry Contractor: Mcintyre Construction Weather: Overcast BP No.: C8-00589 Continuous Inspection: 0 Periodic Inspection: 0 Performed inspection on .reinforcing steel for 8" CM U walls, perimeter walls and one (1 ) interior wall north side of carwash area (4' to 8'). Reinforcing steel was checked for . grade, size, lap, placement and clearance, where applicable. Reinforced cells appeared to be free and clean of excessive mortar projections. Observed the placement of 8.0 yards of 7sk grout (mix 7-GNO) from Knife River for walls noted above. Grout was placed by pump and mechanically consolidated. Walls were grouted solid. One (1) set of three (3) prisms were grouted solid during today's grout placement. Tony (Hap's Masonry) was asked to notify our office when additional services are needed. To the best of our knowledge, the work inspected was in accordance with plans dated 04-10-08 and applicable workmanship provisions of the I.B.C., except if noted above. ., Re;;;;/~ 10- Michael L. Meyer W Technical Manager c: City of Springfield MLM:sc This report" and/or enclosed test data is the-confidential property of the client to whom it is'addressed and pertains to the specific process and/or materialevaluated~ As such, information contained herein shall not be reproduced in part or full and/or any part thereof be disclosed without FE' Testing & Inspection, Inco's written authorization. 750 rwv ComeIIAvenue' CorvaI~s, Oegon 97330' pI1a1e(541) 757-4698, fax (541) 757-2991 29540 BAirpatRoad. Eugene, Oegon 97402 . phone (541)684J849' fax (541) 684-3851 63050 CorporatePlace, Suite 2 . Bend, Oregon 97701 . phone (541) 382-4844 . fax (541) 382-4846 RECEIVED FEB. 2 0 2009 ~Ftl 11;"II~I~;.m.'~lII11J~.m. J , (k,~ " ~I & ConstrucIion Services Compressive Strength of Concrete (ASTM C 39) I Mr. Charlie 'McClain Mcintyre Construction I PO Box 2523 Eugene, Olegon 97402 CLIENT DATE CAST STRENGTH REQUIRED STRENGTH PLACED PRODUCT CODE ADDITIVES LOAD NO. CONCRETE TEMP AIR TEMP POUR LOCATION LOAD 1 SAMPLED TEST DATE 02-17-09 03-10-09 03-10-09 Hold AGE (DAYS) 7 28 28 ** 1 - End Cones PROJECT Enterprise Rent-A-Car . 4396 Main Street Springfield, Oregon DATE PROJECT NO. REPORT NO. B.P.NO. C8-00589 02-10-09 'CAST BY D. Delatte DATE RECEIVED 3000 psi SPECIMEN SIZE 3000 psi SACKS SUPPLIER 30-1V CEMENT MAX SIZE AGG. AEA AIR CONTENT 1 TICKET NO. 3352821 SLUMP 51" F YARDAGE 10.0 OF 29.0 TIME 3WF WEATHER Overcast SPECIMEN STORAGE Perimeter continuous footing and one (1) interior footing, the north wall of carwash area. North side of perim!,ter continuous footing. AREA (IN.') 12.56 WEIGHT (LBS) 8.22 TOTAL LOAD ILBS) 29695 COMPRESSIVE STRENGTH (PSI! 2360 AVERAGE STRENGTH (PSI! TIME OF TEST 7:50 AM 02-17-09 2097017 6208 02-11-09 4" x 8" Knife River 314" 5.5% 4" 7:10AM ASTM C31 TYPEOF FRACTURE- 5 2 - Cone/Split 3 - Columnar 4 - Diagonal 5 - Side (top and bottom) 6 - Side (top or bottom) REMARKS: Bob (Mcintyre Construction) was advised of on-site test results. Reviewed By: 'OJ ~ ..w- Michael L. Meyer Technical Manager c: City of Springfield MLM:sc This report and/or enclosed test data is the confidential property of the client to whom it is ad~ressed and pertains to the specific process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part thereof be. disclosed without.FEI Testing & Inspection, lnc.'s written authorization. 750 tm ComeIIAvenue' CorvaJ6s, CXegon 97330. phale (541) 757-4698. fax (541) 757-2991 29540 B Ailport Road . Eugene, Oegx\ 97402, phale (541)684-Wl9' fax (541 )684-G851 63050 Corporate Place, Suite 2 . Bend, Oregon 97701 . phone (541) 382-4844 . fax (541) 382-4846 SfEl Page 1 of 1 11~'IIHfI:~I~~'~~.IIII~_ Geotechnical & Construction Services Daily Field Report. Client: Mr. Charlie McClain - Project: Enterprise Rent-A"Car Date: 02-16-09 Mcintyre Construction 4396 Main Street . Project No.: 2097017 PO Box 2523 Springfield, Oregon Report No.: E-22395 Eugene, Oregon 97402 Inspector: D. Delatte ID No.: 1 080867-84 ICC Inspection of: Masonry Weather: Overcast Continuous Inspection: 0 Contractor: Mcintyre Construction BPNo.: C8-00589 Periodic Inspection: 0 Performed inspection ~n reinforcing steel for 8; CMU walls, perimeter walls and one (1) interior wall north side of carwash area (footing to 4'). Reinforcing steel was checked for grade, size, lap, placement and clearance, where applicable. Reinforced cells appear to be free of excessive mortar projections, ' Observed the placement of 10 yards of 7 sk grout (mix 7-Gno) from Knife River for walls noted above. Grout was placed by pump and mechanically consolidated. Walls were grouted solid. Cory (Hap's Masonry) was asked to notify our office when additional services are needed. To the best of our knowledge, the work inspected was in accordance with plans dated 04-10-08 and applicable workmanship provisions of the I.B.C., except if noted above. ~~ Michael L. Meyer Technical Manager - c: City of Springfield MLM:sc f?~c€ . F(jIJ IV~D ~O 11717.9 This report and/or enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part thereof be dis~losed without FE! Testing & Inspection, Inc.'s written authorization. 750 r:m ComeIIAvenue' Corvallis, Oregon 97330' ptla1e (541) 757-4698' fax (541) 757-2991 29540 BAirport Road . Eugene, Oregon 97402 . phone (541)684-3849 .fax(541)684-J851 63050 Corporate Place, Suite 2 . Bend, Oregon 97701 . phone (541)382-4844 . fax (541) 382-4846