Loading...
HomeMy WebLinkAboutBuilding Field Test & Inspection Report 2009-2-11 SfEJ Geotechnical & ConstrucIion Services .t:tr.'IIUri;tl~Il' ~~.ml~.IH. February 11, 2009 Project No. 2087024 Report No. E-22369 Addendum- 02-11,09 Mr. Joe Hawes Hawes Investments, LLC 2892 Crescent Ave. Eugene, Oregon 97402 FINAL SUMMARY REPORT International Way Development Package A 400 International Way Springfield, Oregori . Building'Permit No. COM2007-01851 Dear Mr. Hawes, This letter confirms that FEI Testing & Inspection, Inc: performeb special inspection ;ervices in accordance with IBC and as directed by our client for the above-referenced project. We were employed to provide continuous or periodic inspection on specific dates, as documented per our special inspection reports for: Oearthwork 0structural masonry 0epoxyanchors/dowels ~reinforced concrete ~bolts installed in concrete ~structural welding (shop/field) ~high-strength bolts Ospray applied fireproofing ~ ceiling grid , . Based upon our observations and written reports of this work, it is our judgment that the inspected work was performed, to the best of our knowledge, in accordance with the a'pproved plans, specifications, change orders and/or structural en'gineer's instructions, and applicable provisions of Chapter 17 of.the Internationai Building Code, with the following exception: revised roof deck t~lwall attachment per RFI195 is pending in future tenant space 380. . ;, Inspection on the revised roof deck to wall attachment per RFI195 has been completed. To the best of our knowledge, there are no other outstanding "special inspection" issues on this project. . f Respectfully, ;h X.1Au. -- Michael L: Me~ Technical Manager c: Chambers Construction - Dave Bakke (email) Chambers Construction - Brent Stutz (em all) Coughlin, Porter Lundeen - Bobbi Fisher (email) Eric Hall Architects - Ted Corbin (em ail) City of Springfield MLM:sc This report and/or enclosed test data is the confidential property of the client to whom it is addressed and pertains to the speCific process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full ~'nd/or any part thereof be disclosed without FEI Testing & , Inspection, Inc.'s 'written authorization. . I. 750 NW CanelI Avenue. Corvalis, Oregoo 97330, phone (s41) 757-4698, fax (541) 757-2991 29540 BAirport Road, Eugene, Oregoo 97402, phone (541) 684-3849 . fax (541 )684-3851 "',...,^...........______~_....,'___....". '"' __ ,....___.__ .............. '-_ .1,.,......,............... r ,....~,___ ........ Page 1 of 1 SfEt 11~'II~I~;tl~.':':l'II'I~tmI Geotechnical & COnstruction ServiceS Daily Field Report . Client: Mr. Joe Hawes Project: International Way Development Date: 02-10"09 Hawes Investments, LLC Package A Project No.: 2087024 2892 Crescent Avenue 400 International"Way Report No.: E-22365 Eugene, Oregon' 97402 Springfield, Oregon Inspector: L. Postier ID No.: 5232006 ICC Inspection of: Epoxy Anchorsl Welding Weather: Overcast Continuous Inspection: 0 Contractor: Chambers Construction BP No.: COM2007-01851 Periodic Inspection: ~ Performed continu~us inspection during the installati~n of six (6) .1/2" x 7" all thread anchors into the concrete wall at grid lines 5.1 roof level. Prior to installation the predrilled holes were cleaned with a brush and compressed air. Verified minimum embedment of 6". Anchors were secured with Epcon A7 epoxy (ICC ESR.2351/ expiration date 03-25-09).' Also, performed visual inspection on the angle to deck:welds per RFI #195. Completed welds were checked for size, length, profile and locatiqn. . Contractor was asked to notify our office when additional services are needed. . To the best of our knowledge, the work inspected was in accordance with RFI #195 dated 11-20-08,- applicable AWS D1.1 and applicable workmanship provisions of the IBC, except if noted above. Reviewed By: Ih.'f.~ Michaei L. ivleyer Technical Manager c: Chambers Construction - Dave Bakke (email) Chambers Construction - John Shay (email) Coughlin, Porter Lundeen - Bobbi Fisher (email) Eric Hall Architects - Ted Corbin (email) City of Springfield RECEIVE/: F, . . J EB 1 -7 l009 MLM:sc This report and/or enclosed test data is the.confidential property of the client to whom .it.is'addressed and pertains to the specific process and/or material evaluated. As such, information contained herein ~hall notbe:'reproduced in part or full and/or any part thereof be disclosed without FEI Testing & Inspection, lnc.'swrittenauthorization. 750 NVV CorneIiAvenue' Corvallis, Oregon 97330' phone'(541) 757-4698 . fax (541) 757-2991 29540 B Airport Road . Eugene, Oregon 97402 . phone (541)684-J849' fax (541 )684.J851 63050 Corporate Place, Suite 2 . Bend, Oregon 97701 . phone (541) 382-4644 . fax (541) 382-4646