Daily Field Report .
Client:
Mr. Charlie McClain
Mcintyre Construction
PO Box 2523
Eugene, Oregon 97402
Project: Enterprise Rent-A-Car
4396 Main Street
Springfield, Oregon
Date:
Project No.:
Report No.:
Inspector:
ID No.:
02-10-09.
2097017
E-22364
D. Delatte
1080867-88
ICC
Inspection of: Reinforced Concrete
Contractor: . Mcintyre Construction
Weather: Overcast
BP No.: C8-00589
Continuous Inspection: 0
Periodic Inspection: ~
Observed the placement of 29.0 yards of Knife River 3000 psi concrete (mix 30-1V) for
perimeter continuous footing and one (1) interior continuous footing, the north wall of.
car wash area. Concrete was placed by pump and mechanically consolidated. Cast
one (1) set of four (4) 4" x 8" concrete test cylinders. The on-site test results from load
1are as follows: concrete temperature- 51F; air temperature- 36F; air content- 5.5%;
slump- 4". The reinforcing steel for areas noted above was checked by our office on
02-09-09 (reference FEI report E-22357).
Bob (Mcintyre Construction) was advised of the on-site test results and was asked to
notify our office when additional services are needed. .
To the best of our knowledge, the work inspected was in accordance with plans dated
04-10-08 and applicable workmanship provisions'.of the I.B.C., except if noted above.
Reviewed By:.
(h.'j,~
Michael L. Meyer
Technical Manager
c:
City of Springfield
MLM:sc
This report and/or enclosed test data is the" confidential property of the client to whom it is addressed and pertains to the specific
process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part
thereof be disclose.d without FEI Te~ting & Inspection, Inc,'s written autho~zation.
750 NW CaneII Avenue' CavaIIis, Qeg:n 97330, phone (541) 757-4698, fax (541) 757-2991
29540 B AiIpa1 Road . Eugene, Qeg:n 97402 . phone (541) 684-3849 . fax (541) 684-3851
63050 Corporate Place, Suite 2 . Bend, Oregon 97701 . phone (541) 382-4644 . fax (541) 382-4646
~ftJ
. c'b'1
01J/'J
Page 1 of 1
11"'llnft;.I~~'~lInl/~'I.IUSI_
Geotechnical & Construction Services
Daily Field Report
Client: Mr. Charlie McClain Project: ; Enterprise Rent-A-Car Date: 02-09-09
Mcintyre Construction 4396 Main Street Project No.: 2097017
PO Box 2523 Springfield, Oregon Report No.: E-22357
Eugene, Oregon 97402 Inspector: D.' Delatte
ID No.: 1080867-88
ICC
Inspection of: Reinforcing Steel Weather: Overcast Continuous Inspection: 0
Contractor: Mcintyre Construction BP No.: C8-00589 Periodic Inspection: 0
Performed inspection on reinforcing steel for perimeter continuous footing and one (1)
interior continuous footing at north wall of car wash area. Reinforcing steel was
checked for grade, size, lap, placement and clearance. The #4 dowels for tie between
. slab and footing are not installed. Contractor stated doweis will be epoxied at a later
date and would contact EOR regarding embed depth of dowels.
Mcintyre representative was asked to notify our office when additional services are
needed.
To the best. of our knowiedge, the work inspected was in accordance with plans dated
. 04-10-08 and applicable workrpanship provisions of the I.B.C., except if noted above.
Reviewed By:
fh,'-l~
Michael L. Meyer
Technical Manager
c:
City of Springfield
This report and/or enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific
process and/or material evaluated. As,such, information contained herein shall not'be reproduced in part or full and/or any part
thereof be disclosed without FEI Testing & Inspection, Inc.'s written authorization.
;p .
~C
~ ~I t.-
-1 < ~.o
~
MLM:sc
750 NW Canel1 Avenue' CorvaI~s, Oegon 97330, phone (541) 757-4698' fax (541) 757-2991
29540 BAjrport Road . Eugene, Oegon 97402 . phone (541) 684'J849 . fax (541) 684J851
63050 Corporate Place, Suite 2 . Bend, Oregon 97701 . phone (541) 382-4644 . fax (541) 382-4646