Loading...
HomeMy WebLinkAboutBuilding Field Test & Inspection Report 2009-2-10 ~fE' Page 1 of 1 II:Ir.'IUltl;4'~~':I;'IIII~.IH" Geotechnical & Construdion Services Daily Field Report . Client: Mr. Charlie McClain Mcintyre Construction PO Box 2523 Eugene, Oregon 97402 Project: Enterprise Rent-A-Car 4396 Main Street Springfield, Oregon Date: Project No.: Report No.: Inspector: ID No.: 02-10-09. 2097017 E-22364 D. Delatte 1080867-88 ICC Inspection of: Reinforced Concrete Contractor: . Mcintyre Construction Weather: Overcast BP No.: C8-00589 Continuous Inspection: 0 Periodic Inspection: ~ Observed the placement of 29.0 yards of Knife River 3000 psi concrete (mix 30-1V) for perimeter continuous footing and one (1) interior continuous footing, the north wall of. car wash area. Concrete was placed by pump and mechanically consolidated. Cast one (1) set of four (4) 4" x 8" concrete test cylinders. The on-site test results from load 1are as follows: concrete temperature- 51F; air temperature- 36F; air content- 5.5%; slump- 4". The reinforcing steel for areas noted above was checked by our office on 02-09-09 (reference FEI report E-22357). Bob (Mcintyre Construction) was advised of the on-site test results and was asked to notify our office when additional services are needed. . To the best of our knowledge, the work inspected was in accordance with plans dated 04-10-08 and applicable workmanship provisions'.of the I.B.C., except if noted above. Reviewed By:. (h.'j,~ Michael L. Meyer Technical Manager c: City of Springfield MLM:sc This report and/or enclosed test data is the" confidential property of the client to whom it is addressed and pertains to the specific process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part thereof be disclose.d without FEI Te~ting & Inspection, Inc,'s written autho~zation. 750 NW CaneII Avenue' CavaIIis, Qeg:n 97330, phone (541) 757-4698, fax (541) 757-2991 29540 B AiIpa1 Road . Eugene, Qeg:n 97402 . phone (541) 684-3849 . fax (541) 684-3851 63050 Corporate Place, Suite 2 . Bend, Oregon 97701 . phone (541) 382-4644 . fax (541) 382-4646 ~ftJ . c'b'1 01J/'J Page 1 of 1 11"'llnft;.I~~'~lInl/~'I.IUSI_ Geotechnical & Construction Services Daily Field Report Client: Mr. Charlie McClain Project: ; Enterprise Rent-A-Car Date: 02-09-09 Mcintyre Construction 4396 Main Street Project No.: 2097017 PO Box 2523 Springfield, Oregon Report No.: E-22357 Eugene, Oregon 97402 Inspector: D.' Delatte ID No.: 1080867-88 ICC Inspection of: Reinforcing Steel Weather: Overcast Continuous Inspection: 0 Contractor: Mcintyre Construction BP No.: C8-00589 Periodic Inspection: 0 Performed inspection on reinforcing steel for perimeter continuous footing and one (1) interior continuous footing at north wall of car wash area. Reinforcing steel was checked for grade, size, lap, placement and clearance. The #4 dowels for tie between . slab and footing are not installed. Contractor stated doweis will be epoxied at a later date and would contact EOR regarding embed depth of dowels. Mcintyre representative was asked to notify our office when additional services are needed. To the best. of our knowiedge, the work inspected was in accordance with plans dated . 04-10-08 and applicable workrpanship provisions of the I.B.C., except if noted above. Reviewed By: fh,'-l~ Michael L. Meyer Technical Manager c: City of Springfield This report and/or enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific process and/or material evaluated. As,such, information contained herein shall not'be reproduced in part or full and/or any part thereof be disclosed without FEI Testing & Inspection, Inc.'s written authorization. ;p . ~C ~ ~I t.- -1 < ~.o ~ MLM:sc 750 NW Canel1 Avenue' CorvaI~s, Oegon 97330, phone (541) 757-4698' fax (541) 757-2991 29540 BAjrport Road . Eugene, Oegon 97402 . phone (541) 684'J849 . fax (541) 684J851 63050 Corporate Place, Suite 2 . Bend, Oregon 97701 . phone (541) 382-4644 . fax (541) 382-4646