HomeMy WebLinkAboutComments PWE 8/28/2007 .0 Page 1 of I PAULY Linda From: WALTER Eric. Sent: Tuesday, August 28, 2007 10:20 AM . To: PAULY Linda Subject: DRC2007 -00052 Williams Bakery Minor Modification Linda, Given the limited scope of work, I thought it would be appropriate to respond via email. I reviewed the site plan modification' and the only comment Public Works has is regarding where the applicant is proposing' to drain the fueling facility. The City of Springfield Public Works Department has adopted the Portland BES standards. Below is a reference to the standard that addresses fueling facility drainage. . Per Portland Storm water Management Manual Section 4.2, item 3}Drainage: states: " The paved area beneath the cover shall be hydraulically isolated through grading, benns, or drains. This will prevent uncontaminated storm water from running onto the area and carrying pollutants away. Drainage from the hydraulically isolated area shall be directed.. to an approved city sanitary sewer or authorized pretreatment facility". Thank you, Eric A. Walter, P.E. Civil Engineer City of Springfield Public Works Department 225 Fifth Street Springfield, OR 97477 Telephone: (541) 736-1034 Facsimile: (541) 736-1021 Email: ewalter(a)ci.sorinofield.orus Web: www.ci.sorinafield.or.us 9/4/2007