REPORT OF FIELD
CONCRETE INSPECTION
Date: April 11, 1995
Project: EBXX-95-<Xl63
Client: Ms. Leslee Hartwig
Timber Products
P.O. Box 269
Springfield, Oregon
Project Description:
Timber Products
305 S 4th Street
Springfield, Oregon
97477
IQ~!~~f!~iI!!~ij
li~i~~~ii~i~i~i '
I... R~i;ri;tN~irili~f\
'-""""""-'."'-","',"-,'-"--"""";"'-;"'-;. "';'.'-
...,.,.,..'-...-.....,..,....,.....,-,.--,-....,.-,..,.-.................
...................,....................-.-.-.......
~ollciete'l'eilljJi
04-10-95
Q41870
Morse Bros., Inc.
41/2"
i7JAit:il
~~~!iji~~ij~!!!~~~II
Forms
.--.................-...-....
gii;Xd~jif6riti
............ ....,....
.......-............,-....-..".
wi!atiJ'€rII...t
tii
..
12-045-4878
590 II
470
4 (6x12)
36.75
Cloudy
3500 psi placed
3/4" max size agg.
AEA
First floor slab.
REINFORCEMENT: Rebar placed and maintained as per approved prints (see comments below).
REMARKS:
Anchor bolts at wood frame bearing walls were not installed, Contractor
stated he was seeking architects approval to use mechanical fasteners.
Rebar was not discontinued at south east/west construction point.
Inspector: M. Meyer #487/R. Anders
"
c: City of Springfield
Dorman Construction
gLAs Architects - Reed Anderson
C:\wp51IreporIB\inspllim4878,prn
BRAUN
I N T E R T E C NOR T H W EST ,
Inspecting Engineers--Chemists
2285 NUGGET WAY
EUGENE, OR 97403
Phone: (503) 746-9649
FAX: 746-7163
INC.
CONCRETE COMPRESSION TESTS
TESTED FOR:Timber Products
CAST BY:our representative M.Meyer/R.Anders
PROJECT:Timber Products
{ ADDRESS::.3050.1?:"'4th-
":;'Springfield, Oregon
TYPE OF SPECIMEN:6x12 Cylinders
3500 psi, 3/4 MAX SIZED AGGREGATE
ADDITIVES:AEA
SOURCE:Morse Bros., Inc.
PRODUCT CODE:080035-1
CONDITION OF STORAGE:ASTM
PROJECT NO.:EBXX950063
REPORT NO:12-045-4878
I P.O. NO: letter
.PERMIT.' NO: 94:{S70;
DATE MADE:04-!i07.95
DATE REC'D:04/11/95
SACK MIX
SLUMP:4 1/2"
TICKET NO: 133040 AIR TEMP: 47 TIME: 8:25 am CU. YARDS: 9
LOAD NO: 1 CONC TEMP: 59 WEATHER: Cloudy % AIR:
LOCATION OF POUR:First floor slab.
Test
Date
04/17/95
04/17/95
05/08/95
05/08/95
Weight
Pounds
28.6
28.5
3345
Load - lbs.
per sq. in.
3330
3360
Mark
Averaqe
Insp.
cc: Timber Products-Leslee Hartwig
Dorman Construction
gLAs Architects-Reed Anderson
city of Springfield
Morse Bros., Inc.
THIS REPORT IS SUBMITTED AS THE CONFIDENTIAL PROPERTY OF OUR
CLIENT AND IS INTENDED FOR THE USE OF OUR CLIENT ONLY. NO
OTHER PERSON OR ENTITY MAY UTILIZE THIS REPORT OR ANY PORTION
THEREOF WITHOUT OUR WRITTEN AUTHORIZATION.
Age
Tested
7 day
7 day
28 day
28 day
BRAUN'M
I NTE RTEC
Braun Intertec Northwest
2285 Nugget Way
Eugene, Oregon 97403
503.746.9649 Fax: 746.7163
Engineers and Scientists Serving
the Built and Natural Environments
REPORT OF FIELD
CONCRETE INSPECTION
Date: March 31, 1995
Project: EBXX-95-o063
Client: Ms. Leslee Hartwig
Timber Products
P.O. Box 269
Springfield, Or~gon 97477
Project Description:
Timber Products
305 S 4th Street
Springfield, Oregon
II. . -. .
n............... ____.__.......... ..........
... Date of InSPection ,......
03-29-95
941870
..:._.,-.-...-,.,.,-..,.,-,'.................,-,...,-',."..,-,....-,..-:-,.,-;-,.;-:,..;.:.,.,.
"""""""'-,""",",-,",','-""'''''''''',-,'-''
..,.._._..._...,-.....-,-,..-...........,._,......-...._---,',',-,'.-,',',-,',-,-,.
Reporf Number .
12-035-4823
3 1/2"
660
Morse Bros., Inc.
710
4 (6xI2)
4.0
J g~~i#~G~#~l~l~ti~ Forms
Clear
3500 psi placed Retaining walls at lines A~7; Line A, between 5 and 6.
3/4" max size agg.
AEA
.-- I
--
REINFORCEMENT: Rebar placed and maintained as per approved prints.
REMARKS:
Inspector: S. Wilder #480
c: City of Springfield
Dorman Construction
gLAs Architects - Reed Anderson
C;\wpSl \reports\insp\tim4823 .pro
BRA U N
I N T E R T E C 'N 0 R T H W EST ,
Inspecting Engineers--Chemists
2285 NUGGET WAY
EUGENE, OR 97403
Phone: (503) 746-9649
FAX: 746-7163
INC.
CONCRETE COMPRESSION TESTS
TESTED FOR:~imber Products
CAST BY:our representative S. Wilder
PROJECT:Timber Products
ADDRESS: 305->S>'4th ~,
>' Springfield, Oregon
TYPE OF SPECIMEN:6x12 Cylinders
3500 psi, 3/4 - MAX SIZED AGGREGATE
ADDITIVES:AEA
SOURCE:Morse Bros., Inc.
PRODUCT CODE:080035-1
CONDITION OF STORAGE:ASTM
PROJECT NO.:EBXX950063
REPORT NO:12-035-4823
P.O. NO:letter
IPERMIT NO :g4~i870>
DATE MADE:03/29/95
DATE REC'D:03/30/95
SACK MIX
SLUMP:3 1/2"
TICKET NO: 132762 AIR TEMP: 71
LOAD NO: 1 CONC TEMP: 66
LOCATION OF POUR:Retaining walls
TIME: 2:30 pm
WEATHER: Clear
at lines A-7,
CU. YARDS: 4
% AIR:
Test Weight Load - lbs. Age
Date Mark Pounds per sq. in. Averaqe Tested
04/05/95 28.7 3130 7 day
04/05/95 28.7 3060 ,3095 7 day
04/26/95 28.8 4700 28 day
04/26/95 28.7 4760 4730 28 day
Insp.
cc: Timber Products-Leslee Hartwig
Dorman Construction
gLAs Architects-Reed Anderson
City of springfield
Morse Bros., Inc.
THIS REPORT IS SUBMITTED AS THE CONFIDENTIAL PROPERTY OF OUR
CLIENT AND IS INTENDED FOR THE USE OF OUR CLIENT ONLY. NO
OTHER PERSON OR ENTITY MAY UTILIZE THIS REPORT OR ANY PORTION
THEREOF WITHOUT OUR WRITTEN AUTHORIZATION.
BRAUN'M
I NTE RTEC
Braun Intertee Northwest
2285 Nugget Way
Eugene, Oregon 97403
503,746,9649 Fax: 746,7163
Engineers and Scienfists Serving
the Built and Natural Environmenfs
REPORT OF FIELD
CONCRETE INSPECTION
Date: March 21, 1995
Project: EBXX-95-0063
Client: Ms. Leslee Hartwig.
Timber Products
P.O. Box 269
Springfield, Oregon 97477
Project Description:
Timber Products
305 S 4th Street ,
Springfield, Oregon
IjQ~!~j~f;![~lItl~jj'
1;I~riNijffi~~~~,......i
1~~~t~~;~fK!~!~tl#i
03-17-95
941870.
Morse Bros" Inc.
4"
.........................".......................,
-.............................................,..-....
q\jt!hg~~h~!~!~h$.:
Forms
l
12-035-4773
670
690
4 (6xI2)
24.0
Pt Cloudy
3500 psi placed
3/4" max size agg,
AEA
Foundation walls on line 7, from AlOE; On line E, from 6 to 7; On
line A, from 6.5 to 7, from footing to top of wall.
REINFORCEMENT: Rebar placed and maintained as per approved prints.
REMARKS:
Inspector: S. Wilder #480
c: City of Springfield
Dorman Construction
gLAs Architects - Reed Anderson
C:\wp51 \reports\insp\tim4773.pro
/