HomeMy WebLinkAboutPermit Field Test & Inspection Report 1997-8-27 BRAUN'M I NTE RTEC Braun Intertec Corporation 2285 Nugget Way Eugene, Oregon 97403 541,746-9649 Fax: 746-7163 Engineers and Scientists Serving the Built and Natural Environments August 27, 1997 Project EBXX-97-0321 Report E-60 110 Mr. Tom Stewart Advanced Building Systems 28748 Royal Avenue . Eugene, Oregon 97402 Re: Headstart Play Structure 221 BStreet Springfield, Oregon B.P. No. 97-0958 Met on-site with contractor to verify that the 5/8" A-325 High Strength Bolts in the beam to column connections are in a "snug-tight" condition and bolts have been marked, Witnessed the application of the additional one-third turn-of-the-nut as required by Uniform Building Code for 5/8". bolts, The bolt markings indicated that the procedure was prqperiy completed. Contractor was asked to notify our office when additional II services are needed. . . Sincerely, mL. kJ Michael L. Meyer rincipa'~ Willamette Valle Operations Manager (tlOd~' Raymon;~~i, Superviso(~ Eugene Branch c: '. ,-City,-o(Spriiigfield' "-'! !l" :' .' , ' " " " 1"! '. 'f' I ~ I: -I, . " f:\groups\pub-data\wpdoc\rcports\welds\adv60 II O.hca "(1 BRAUN I N TE R T E C NOR T H W EST Inspecting Engineers--Chemists 2285 NUGGET WAY EUGENE, OR 97403 Phone: (503) 746-9649 FAX: 746-7163 CONCRETE COMPRESSION TESTS TESTED FOR:Advanc~dBuilding System CAST BY:our rep. R. Crawford PROJECT:Headstart Play Structure ADDRESS:22~ B Street springfield, TYPE OF SPECIMEN:6 x 3000 psi, 3/4" MAX ADDITIVES: AEA SOURCE: Morse Bros.,- Inc. PRODUCT CODE:080135-1 CONDITION OF STORAGE: ASTM- Oregon 12 SIZED AGGREGATE PROJECT NO.:EBXX970321 REPORT NO:12-087-7732 P.O. NO: PERMIT NO:97-0958 DATE MADE:08/15/97 DATE REC'D:08/16/97 SACK MIX 3500 psi placed SLUMP: 4" AIR TEMP: 66 CONC TEMP: 73 POUR:Monolithic slab TIME: 7:30 am WEATHER: clear east of building CU. YARDS: 8.5 % AIR: TICKET NO: 835422 LOAD NO: 1 LOCATION OF ..... . Test Date 08/22/97 08/22/97 09/12/97 09/12/97 weight Pounds 28.4 28.6 Load - lbs. per sq. in. 3100 2970 Averaqe Mark 28.5 28.6 4320 4230 , cyl only ., ~'.' ': _-;:~:,-"'~' "': 3035 4275 Note: Advised super,intendent of 'on-si te test results. cc: Advanced Building Sys~ms-T.Stewart City of Springfield~ Morse Bros., Inc. "\" "''. ., ,- <. 0 '"'., THIS REPORT IS SUBMITTED AS THE CONFIDENTIAL PROPERTY OF OUR CLIENT AND IS INTENDED FOR THE USE OF OUR CLIENT ONLY. NO OTHER PERSON OR ENTITY MAY UTILIZE THIS REPORT OR ANY PORTION THEREOF WITHOUT OUR WRITTEN AUTHORIZATION. Age Tested 7 day 7 day 28 day 28 day BRAUN'M I NTE RTEC Braun Inter:1ec Corporation 2285 Nugget Way Eugene, Oregan 97403 541,746-9649 Fax: 746-7163 Engineers and Scientists Serving' the Built and Natural Environments DAILY FIELD REPORT August 14, 1997 Advanced Building Systems Headstart Play Structure 221 B Street Springfield, Oregon mr~!!!!m~~.H?ITiI III Reinforcing Steel ~p!\SI!Is~!!~~m1II See field observations. !tt9j!\S(1~l!!m!i~t:I EBXX -97 -0321 g~~2t(N~m!i~t;Ii... E-600 12 mQ;N@j!i~tIt. .........\I...tI.... nla 1!~!!~!!jg!:iitm!!:N~m!iet(} 97 -0958 Clear n;~~9!;~!r~f!jjt~;I;!t Monolithic Slab I I I :1 I I erformed visual inspection on the rebar and anchor bolts on monolithic floor slab for the. play structure canopy, Reinforcing steel was checked for grade, size, lap, and placement. The rebar and anchor bolts are secured in laced. Rebar supported on concrete dobie blocks. Rebar and anchor bolts placed in accordance with on-site plans om Schaudt, Stemm, & Wild, dated June 17, 1997, and Chief Industries, Inc., dated May 28, 1997, and revision ated June 12, 1997 (in-set column footing), To the best of the inspector's knowledge, the work inspected was in ccordance with the building department approved design drawings, specifications, revisions, and applicable orkmanship provisions of the V.B.C., except if noted above, Inspector: D. Smith - ICBO# 87732 If you have any questions regarding this report,. please feel free to call Raymond V, Aliperti at (541) 746-9649. c: City of Springfield Advanced Building Systems - Tom Stewart As a mutual protection to clients, the p~blic. and ourselves, all reports are submitted as the confidential property of clients and arc intended for the use of our clients only. ~o other person or entity may utilize the report or any portion thereof without our written authorization. ~ , .L .., " , ~ ' c f: Igroupslpub-data Iwpdaclreportslinspladv600 12,hea