Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 1995-12-21 e BRAUN'M I NTE RTEC Braun I"tertec Northwest, 2285 Nugget Way Eugene, Oregon 97403 503.746,9649 Fax: 746,7163 Engineers and Scientists Serving ,he Built and Natural Environments' December 21, 1995 Project EBXX-95-0136 Report E-56242 Mr. Duane Hopkins Springfield Forest Products P.O. Box 719 Springfield, Oregon 97477 Dear Mr. Hopkins: Re: Parts Storage Building Springfield Forest Products 1651 South F Street Springfield, Oregon P.O. #C0335 -B.P. No. 95-0238 :' ,J':\ 'J: ?; I:.!: j:+~ I ,:. ~'j Project Information December 19, 1995 Report Performed visual inspection on the repair weldments on the W8x24 knee brace stiffners near the west end of the building. The welds were checked for size (verified 1/4" by Coakley Engineering), profile, and location (welded all-around), and appear acceptable as per approved prints, engineers instructions, and'the AWS Dl.l Steel Welding Code. Sincerely, ,qzJ ~~~~ft2B iEu,geneBr~nch .... ,_. .-...--,...., '''_', ....... , ,,' .' :.!:.": c: .CoakleyEngineei's'" '--'. ',_.~~ ",. . City of Springfield .._~ ". ....,...-.. .. . .~..._-". - .. . ... "- ':;:'.':':,".:-:;:.'";: .~..!.' " ~ '. ".:1, c:\wp51 \reports\welda\spr56242.spr 'r BRAUN'M I NTE RTEC Braun Infertee Northwest, 2285 Nugget Way Eugene, Oregon 97403 503.746.9649 Fax: 746,7163 Engineers and Scientists Serving the Built and Natural Environments November 10, 1995 Project EBXX-95-0136 Report E-56136 Mr. Duane Hopkins Springfield Forest Products P,O. Box 719 Springfield, Oregon 97477 . 'Dear Mr.' Hopkins: Re: Parts Storage Building Springfield Forest Products 1651 South F Street Springfield, Oregon , P.O. #C0335 - B.P. No. 95;-0238 . Project Information Weldments November 09, 1995 Report Performed visual inspection on the completed field weldments connecting the knee-braces to the columns and beams near the west end of the 50' x 120' parts storage building. The . welds were checked for size, length, profile, location and workmanship, Welds on both braces were marked for repair due to undercut, porosity, undersize, poor profile andlor workmanship. Dick Duncan (Springfield Forest Products) was advised and was asked to notify our office when additional services are needed. Note: Contacted Bob Coakley (Coakley Engineering) to verify weld size requirement, Was advised that 114" fillet welds are required on all sides of both connections. S incerel y , ~~~^J\OX---OS Michael L. 'Meyer ~ ~e~ Eugene Branch ' c: Coakley Engineers City of Springfield c:\wp51 \reporu\wetda\spr56136.spr