Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 1997-1-10 BRAUNSM INTERTEC Braun Intertec Co~poration 2285 Nugget Way Eugene, Oregon 97403 . 541.746-9649 Fox: 746-7163 Engineers and Scienfists Serving the Built and Natural Environments January 10, 1997 Project No. EBXX-97-0005 ," Report E-58348 'c. . .~ Mr. Brent McClean McClean's Masonry P.O, Box 766 Springfield, Oregon 97477 Re: C & E Rentals 1570 South A Street Oregon . q~- \~5 January 08, 1997 Dale Webber A WS# 93050801 Performed visual inspection on column base plates, Detailed tield drawings did not have weld symbols for base plate embeds, Notes on drawings indicate 3116" typ, if no symbols shown. Column bases on-site have 3116" fillet welds, Certitication of welder was II received. To the best of our knowlege, column base plates weldments are in conformance with A WS D l.l (static) code, ' Sincerely, m. ~.~ (()-tLu ))./~ Michael L. Mey;r,- Pri;;'cipal Willamette Valley Operations Manager }!., 111 LLn I)) *". ~) Raymon'dY. -':;'I~ S:;;visor )I Eugene Branch c: City of Springfield c :\wp5 t \reports\wclds\mcc5 8348 .c&e