HomeMy WebLinkAboutPermit Field Test & Inspection Report 1997-1-10
BRAUNSM
INTERTEC
Braun Intertec Co~poration
2285 Nugget Way
Eugene, Oregon 97403 .
541.746-9649 Fox: 746-7163
Engineers and Scienfists Serving
the Built and Natural Environments
January 10, 1997
Project No. EBXX-97-0005 ,"
Report E-58348
'c.
.
.~
Mr. Brent McClean
McClean's Masonry
P.O, Box 766
Springfield, Oregon 97477
Re: C & E Rentals
1570 South A Street
Oregon
. q~- \~5
January 08, 1997
Dale Webber A WS# 93050801
Performed visual inspection on column base plates, Detailed tield drawings did not have
weld symbols for base plate embeds, Notes on drawings indicate 3116" typ, if no symbols
shown. Column bases on-site have 3116" fillet welds, Certitication of welder was
II received. To the best of our knowlege, column base plates weldments are in conformance
with A WS D l.l (static) code, '
Sincerely,
m. ~.~ (()-tLu ))./~
Michael L. Mey;r,- Pri;;'cipal
Willamette Valley Operations Manager
}!., 111 LLn I)) *". ~)
Raymon'dY. -':;'I~ S:;;visor )I
Eugene Branch
c: City of Springfield
c :\wp5 t \reports\wclds\mcc5 8348 .c&e