Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 1997-2-24 BRAUN'M INTERTEC Braun Interiec Corporation 2285 Nugget Way Eugene, Oregon 97403 541.746-9649 Fax: 746-7163 Engineers and Scienfists Serving the Built and Natural Environments February 24, 1997 Project No. EBXX-96-0424 Report E-58646 Mr. Bob Kostrba P,O, Box 107 Springfield, Oregon 97477 Re: CIGM Expansion 1425 South B Street Springfield, Oregon C.:\ ~'~ 'm41 P.O. No. Hi26 ~f'. q~- DI12 February 20, 1997 Dale Webber A WS# 93050801 Performed visual inspection on the completed weld repairs in the expansion area on the south side of the existing building, All column to beam welds, and the plate to beam welds at center column on north side have been repaired (ref: our report no, E58221, dated 12113/96), To the best of the inspector's knowledge the work checked is in conformance with submitted design drawings and applicable A WS DI.I (static) code with the following exception: certitic~tion papers for Lynn Anderson do not list 4G (overhead welding) as a ql!aiified position (see 3hove referenced report), Also, re-inspected bolted heam to existing wall connection at center of north side, New plate and six (6) long grade 8 bolts have been installed, Bolts and nuts appear to be in a 'snug-tight' condition, Contractor was asked to notify our oftice when additional services are needed, Sincerely, 1?;,~~~ Willamette Valley Operations Manager !~v~~~ Eugene Brancb c: City of Springtield . c: \wpSl '.rcports\wclds\cig58646.cig .\ - " <-~ BRAUN'M INTERTEC Braun Intertec Corporation 2285 Nugget Way Eugene, Oregon 97403 541,746-9649 Fax: 746-7163 Engineers and Scientists Serving the Buill and Natural Environments December 13, 1996 Project No, EBXX-96-0424 Report E-58221 Mr. Bob Kostrba P.O. Box 107 Springfield, Oregon 97477 Re: CIGM Expansion .14~5South.R.Street . . Springfield, Oregon .,..B.P....96-lW(i:f P.O. No. 1026 t.i~z. December II, 1996 'DaleiWebber 'I'\WS#93050801 /"David Smith ',. .CIGM:;..,. ' ".;J, ; .... .' .. f.... .",.,. " ,".,:-: (', ':;-'-,1" :',:., Performed visual inspection on the completed weldments in the expansion area on the south side of the existing building for conformance to design drawings, U ,B,C. and applicable AWS DI.I (static) code, Advised that Lynn Armstrong was the welder on the job. It appears that E7018 SMA W was used on all weldments, According to submitted documentation, Lynn Armstrong was certified in the 3G position in .1990 by Northwest I Testing. There was no documentation received that welder was engaged in the given process needed to perform vertical and overhead fillets, Contractor was advised welder was not certified in accordance with A WS D 1. I code, All column to beam welds and plate to beam weld at center column on north side were marked for repair due to overlap, undercut andlor poor workmanship, All column to base I plate welds are acceptable. Performed inspection on the bolted beam to existing wall connection at center of north side of n(lw addition. Six (6) 3/4" grade.8 bolts are in-place in over-size slotted hOles" II Washers were used under the bolt head and n'ut and appear to be concaved on beam flange side:'- Bolt.diimeter and msher thickness -do' not app'earto - conform to AISC manmil. or". . U,B,C,- recommendations for~us~ with oversize slotted holes.. Recommend,owner contact _ .".:,../"... .' '," - . '..' ". ,.,. structural'engmeer for review and acceptance of as-bUilt connectIons. -: '_I! ,-, "",{".)": \.' : :\ , Sincerely, fYI.L ;n~-eJu Michael L. Meyer, PridCipal,l.'q). Willamette Valley Operations Manager c: City of Springfield c:\wp51\reports\welds\cig58221.cig CIGM Project EBXX-96-0424 Report E-S8221 December 13, 1996 Page 2 /2, IOLLn~.~\ Ray,mond V-:-A1i~erfi, Supervisor ~ Eugene Branch