Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 1997-1-4 BRA U N I N T E R T E C NOR T H W EST Inspecting Engineers--Chemists 2285 NUGGET WAY EUGENE, OR 97403 Phone: (503) 746-9649 FAX: 746-7163 CONCRETE COMPRESSION TESTS TESTED FOR:Premier Auto Glass CAST BY:our rep. D. Craig PROJECT:Premier Plaza \ ADDRESS:3555-i;-.i1teway st. Springfield, Oregon TYPE OF SPECIMEN:6 x 12 3000 psi, 3/4 MAX SIZED AGGREGATE ADDITIVES: AEA SOURCE:Morse Brothers Inc. PRODUCT CODE:80030-1 CONDITION OF STORAGE:ASTM PROJECT NO.:EBXX970001 REPORT NO:12-017-7088 P.O. NO:.. PERMIT NO:96-1079 DATE .MADE: 01/03/97 DATE REC'D:01/04/97 SACK-MIX- - SLUMP: 5. 0" TICKET NO:746853 LOAD NO: 1 LOCATION OF AIR TEMP: 40 TIME: 7:50am CU. YARDS: 10.0 CONe TEMP: 63 WEATHER:P.Cloudy % AIR: 4.0 POUR:Continuous Footing on lines: 1, lA, A, 3A, 4A, 7, C.G 3A, line B from 5 to 7, elevator footing and slab. s taken on line Band 5). Test Date 01/10/97 01/10/97 01/31/97 01/31/97 Weight Pounds 27.8 27.7 3515 Load - lbs. per sq, in. 3470 3380 Mark Averaqe cyl. only note: Advised superintendent of on-site test results cc: Dorman Construction BMGP Engineers-D.Stivers Michael Lewaller ./ City of Springfield , , THIS REPORT IS SUBMITTED AS THE CONFIDENTIAL PROPERTY OF OUR CLIENT AND IS INTENDED FOR THE USE OF OUR CLIENT ONLY. NO OTHER PERSON OR ENTITY MAY UTILIZE THIS REPORT OR ANY PORTION THEREOF WITHOUT OUR WRITTEN AUTHORIZATION. from 2A - sample wa Age Tested 7 day 7 day 28 day 28 day Hold