Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 2009-1-20 l....~;lInformation ,.,~. .To Build On Engineering . Consulting . Testing DAiLY FIELD REPORT Date Performed: Client: January 20, 2009 Ms. Lauretta Davies Jerri"s Home Improvement P.O Box 2611 Eugene, Oregon 97402 Report Number: 722-90008-4 Project Name: Jerr)"s-Warehouse Renovations Project Lo:::;ation: 2525 Oiympic Street Springfield, Oregon P.O. No.: Type of Inspection: Z4175LD Soils Observation BP# COM2008-01S9S Weather:' Clear Field Observations and Comments On site to observe exposed subgrade soils/standing water for the truck ramp. The footing excavation was cut to grade and the water was above that elevation. A soil probe was used to assist us in determining the stability of the in-place soils. Soil probe penetrations were only 4 to.6 inches indicating a relatively firm stable subgrade. However, in orger to place and compact the one-foot of rock that is required under the footings, the water level would need to be below the excavation depth. We recommend pumping 1he water out and keeping it low enough until the rock has been placed, compacted, and test~d. We also recommend placing a foundation drain around the footi~g. To the best of our knowledge, the work inspected was in accordance with the building department approved design drawings, specifications and applicable workmanship provisions of the International Building Code. Inspector: Raymond Aliperti CCB #176269 If you have any questions regarding this report, please feel free to contact us at 541-746-9649. Respectfully Submitted, -Mri''''''.' David Smith Branch Manager c: City of Springfield Chambers Construction - David Bakke Robertson Sherwood Archi1ects - Scott Stolarczyk Metzler Engineering - Scott Metzler THIS REPORT IS PROVIDED FOR THE INFORMATION OF THE CLIENT ONL y, THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AN[J ITS TRANSMITTAL TO A THIRD PARTY, BY ANY MEANS, EXCEPT IN FULL, WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES, IS PROHIBITED. Professional Service Industries, Inc.. 1040.A Shelley Street. Springfield, OR 97477 . Phone 541r146-9649 . Fax 541r146-7163 l...~;z Information ,.,..,. .To Build On Engineering. Consulting . Testing DAILY FIELD REPORT Date Performed: January 26, 2009 Report Number: 722-90008-7 Client: Ms, Lauretia Davies Jerry's Home Improvement PO. Box 2611 Eugene, Oregon 97402 ProjeGt Name: Jerr)"s~Warehouse Renovation Project Location: 2525 Olym piC Street Springfield, Oregon COM2008-01595 Clear P.O. No.: Contractor; Type of Inspection: Z4175LD Chambers Construction Reinforcing Steel \Pe[ITlit t-!,o.: Weather; Field Observations and Comments Performed visual inspection of reinforcing steel at the following locations: Loading Dock Footing. Reinforcing steel was secured using tie wire and will be supported on concrete dobie blocks during placement of concrete. To the best of our knowledge, the work inspected above was in accordance with the building department approved design drawings, specifications, and applicable workmanship provisions of the International Building Code. Inspector; Chris McDonald ICC#5298238.47 CCB# 176269 If you have any questions regarding this report, please feel free to contact us at 541-746-9649. Respectfully Su D~ David Smith Branch Manager c: City of Springfield Chambers Construction - David Bakke Robertson Sherwood Architects - Scott Stolarczyk Metzler Engineering - Scott Metzler ttted, rvic~ tstries, Inc. THIS REPORT IS PROVIDED FOR THE INFORMATION OF THE CLIENT ONL Y. THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD PARTY, BY ANY MEANS, EXCEPT IN FULL, WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES,'IS PROHIBITED. Professional Service Industries, Inc. .1Q40-A Shelley Street. Springfield, OR 97477. Phone 541f746-9649. Fax 541f746-7163 l n~;lInformation ",~. .To Build On Engineering . Consulting . Testing c'5- O\SCi'::> ) DAILY FIELD REPORT Date Performed: January 27, 2009 Report Number: 722-90008-8 Client: IVls. Lauretta Davies Project Name: Jer~r's~WarehDUS€ Renovations Jerry's Home Improvement P.O Box 2611 Project Location: 2525 Olympic Street Eugene, Oregon 97402 Springfield, Oregon P.O. No.: Z4175LD Permit No.: Contractor: Chambers Construction Weather: Overcast Type of Inspection: Reinforced Concrete Field Observations and Comments Performed visual inspection during the placement of concrete for the Truck Ramp Footings. Concrete was placed by truck and mechanically consolidated. Cas1 one (1) set of four (4) (4x8) concrete test cylinders. To the best of our knowledge, the work inspected above was in accordance with the building department approved design drawings, specifications, and applicable workmanship provisions of the International Building Code. Tvoe of Material Supplier Mix# Slump Air Content Ambient Temperature Material Temperature 'Time Placed Design Strength (psi) Number of Samples Total Yarda!je Placed Inspector: Pete Furlong ACI#00083536 CCB# 176269 Set #1 Knife River 2430NE5200 51/2" 38' 48' 10:10AM 3000 4 18 If you have any questions regarding this report, please feel free to contact us at 541-746-9649. Respectfully Subm ted, ~prOfeSSional 5e ice In \ /- vid Smith ' Branch Manager c: City of Springfield Chambers Construction - David Bakke Robertson Sherwood Architects - Scott StoJarczyk Metzler Engineering - Scott Metzler ries, Inc. THIS R~PORT IS PROVIDED FOR THE INFORMATION OF THE CLIENT ONL Y. THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD p_IO",I""'" lleMJe_rrIO's';Il\\G, W1U>WJA _H'WSl_''ll/iIiA!jlr.r;:WM\ff4i'jil;V~h&w!j41'rriW9g,rif.Sfi,j,l'5'4'tfIljEf.l', 63 l"'~;lInformation ,.,~. .To Build On Engineering . Consulting . Testing DAiLY FiELD REPORT Date Performed: January 21, 2009 Ms. Lauretta Davies Jerr)"s Home Improvemem P.O. Box 2611 Eugene, Oregon 97402 Report Number: 722-90008-5 Client: Project Location: Jerr)"s-Warehouse Renovations 2525 Olympic Street Springfield, Oregon Project Name: P.O. No.: Type of Inspection: Z4175LD Epoxy/Welding BP# COM2008-01595 Wealher:- Inside Field Observations and Comments As requested a PSI representative was on-site to inspect the following: 1) Epoxy anchored bolts for the door opening at gridline F at 7 (detail 2/S1). The 5/8" diamter all thread rods were 14" long and embedded a minimum of 5" vertically into the lintel. Three all thread rods were installed using Hilti Hit HY 150 epoxy with an ICC# 5193. 2) Exposed subgrade soils for the interior truck ramp. Exposed soils visually appeared to be native black and brown clay. Soil probe penetrations ranged in depth from 3 to 4 inches indicating a relatively firm, stable subgrade at this time. Both footing and slab subgrade soils were observed. Each area is scheduled to receive a minimum of 12" of imported crushed rock. Rock will be tested after it has been compacted. 3) Single Pass welds for door frames at gridline F at 7 and E.5 at 9. Welds were inspected for size, length, profile and location. To the best of our knowledge, the work inspected was in accordance with the building department approved design drawings, specifications and applicable workmanship provisions of the AWS D1.1 Code. Inspector: Raymond V. Aliperti ICC#1017075-85 CCB #176269 If you have any questions regarding this report, please feel free to contact us at 541-746-9649. Respectfully Sub Professional Se Q1il\ Branch Manager c: City of Springfield Chambers Construction - David Bakke Robertson Sherwood Architects - Scott Stolarczyk Metzler Engineering - Scott Metzler THIS REPORT IS PROVIDED FOR THE INFORMA nON OF THE CLIENT QNL Y. THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD PARTY, BY ANY MEANS, EXCEPT IN FULL, WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES;IIS PROHIBITED Professional Service Industries, Inc.. 1Q40-A Shelley Street. Springfield, OR 97477. Phone 5411746.9649. Fax 5411746-7163 l"'~;l lriformation. ",~. .To Build On Engineering. Consulting. Testing DAiLY F~ELD REPORT Date Performed: Client: January 12, 2009 Ms. Lauretta Davies Jerry's Horns Improvement P.O Box 2611 Eugene, Oregon 97402 Report Number: 722-90008-1 Project Name: Jerrl"s-Warehouse Renovations 2525 Olympic Street Springfield, Oregon Proje~t Lo~ation: P.O. No.: Type of Inspection: Z4175LD Epoxy BPI! COM200S-0159S , Weather: Inside Field Observations and Comments Performed continuous inspection during the installation of three (3) 518" diameter all thread epoxied anchor bolts in the following locations: Existing east CMU wall on line 9 between C and D at door header. Prior to Installation the predrilled holes were cleaned using a nylon brush and compressed air. Verified minimum embedment depth of 5 inches for the 5/8" and 6 3/3" for the 3/4". The above listed epoxy anchors were installed using Hiltl Hit HY 150. Contractor stated the nuts would be tightened after epoxy has cured. To the best of our knowledge, the work inspected was In accordance with the building department approved design drawings detail A~A, specifications and applicable workmanship provisions of the International Building Code. Inspector: Steve Wilder eeB #176269 If you have any questions regarding this report, pi ease feel free to contact us at 541-746-9649. , Respectfully Su~tted, 1;:s"f ~~ ItQm.., I'" David F. Smith Branch Manager c: City of Springfield Chambers Construction - David Bakke Robertson Sherwood Architects - Scott Stolarczyk Metzler Engineering - Scott Metzler THIS REPORT IS PROVIDED FOR THE INFORMATION OF THE CLIENT ONL Y. THE REPRODUCTION OF THIS REPORT, BY ANY METHOD. AND ITS TRANSMITTAL TO A THIRD PARTY, BY ANY MEANS, EXCEPT IN FULL, WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES, IS PROHIBITED. Professional Service Industries.. Inc.. 1040-A Shelley Street. Springfield, OR 97477. Phone 541/746"9649. Fax 541/746-7163 l ra~;l Information ,.,..,. .To Build On Engineering. Consulting. Testing Dt--iL Y rlELD REPORT Date Performed: Client: January 16, 2009 Ms. Lauretta Davies Jerrj"s Homs Improvement PO Box 2611 Eugene, Oregon 97402 Report Number: 722-90008-3 Project Name: Jerr)"s-Warehouse Renovations Project Location: 2525 Qiympic Street Springfield, Oregon P.O. No.: Type of Inspection: Z4175LD Welding BP# COM200S-01595 Weather: Inside Field Observations and Comments Performed periodic visual inspection of the following items at Gibson Steel Fabrication Shop: two (2) loading dock embed frames Welds were inspected for size, length, profile and location. To the best of our knowledge, the work inspected was in accordance with the building department approved design drawings, specifications and applicable workmanship provisions of the AWS 01.1 Code. 'Inspector: David F. Smith ICC#0877340-85 CCB #176269 If you have any questions regarding this report; please feel free to contact us at 541-746-9649. Respectfully Submitted, Professional Service Industries, Inc. ~Dav . Raymond V. Aliperti Project Manager c: City of Springfield Chambers Construction - David Bakke Robertson Sherwood Architects - Scott Stolarczyk Metzler Engineering - Scott Metzler THIS REPORT IS PROVIDED FOR THE INFORMA TlON OF THE CLIENT ONL Y. THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD PARTY, BY ANY MEANS, EXCEPT IN FULL. WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES"IS PROHIBITED. Professional Service Industries, Inc.. 1040-A Shelley St~eet. Springfield, OR 97477. Phone 541n46-9649. Fax 541n46-7163