Loading...
HomeMy WebLinkAboutPermit Building 2008-6-12 (3) , >- Status Issued CITY OF ~nuNGFIELD Building/Combination Permit PERMIT NO: COM2008-00438 ISSUED: 06/12/2008 APPLIED: 04/0112008 EXPIRES: 07/29/2009 VALUE: $ 10,783,928.00 225 Fifth Street, Springfield, OR 541-726"3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line SITE ADDRESS: 2109 J ST ASSESSOR'S PARCEL NO.: 1703361200100. Springfield TYPE OF WORK: School TYPE OF USE: New PROJECT DESCRIPTION: New elementary school- Maple Elementary Public Owner: ,SPRINGFIELD SCHOOL DISTRICT 19 Address: 525 MILL ST SPRINGFIELD OR 97477 Phone Number: 541-726-3218 I CONTRACTOR INFORMATION I Contractor Type Contractor License Architect DAVE GUADAGNI, AlA , General JOHN HYLAND CONSTRUCTION INC 46071 Electrical OREGON ELECTRIC CONSTRUCTION INC 203 Fire Contractor INTEGRATED ELECTRONIC SYSTEMS 165599 Low Voltage Electrical 0 SECURETECH INC 156618 Plumbing OREGON CASCADE PLUMBING & HTG IN 127 Sewer HAROLD PRIMROSE EXCAVATING 165764 BUILDING INFORMATION. Expiration Date 07/11/2010 07/01/2010 07/13/2009 08/08/2009 11/25/2010 12/09/2008 Phone 541-342-8077 541-726-8081 503-234-9900, I 541-485-4456 541-521-2837 503-588-0355 (541) 935-2221 Lot Size: Sq Ft 1st Floor: Sq Ft 2nd Floor: Sq Ft Basement: Sq Ft Garage/Carport AUENTlo~<r::ltb~rnw requires yout,o follM1 rulesgffi--IJP.'!;I!t~,o$i1~ Oregon Utility _ , "T"'-___~..I....,.,..,......eotfnrth ~~~ I~:RMIT SHALL EXPI~"o/'NT 1NFORMA ~1~~Ra952-00;~o6'16'ihr-Ough OA,R 9r;~~~01- T IS NOT 0090 You may obtaiREQ,l!lIREiDtPIO..Itim-kY , AUTHORIZED UNDER THISPERMI, " the center.,jNote: the telephone F;ontyard Selbofv~fVlENCED ORIS ABANDONED ~Iay DlSt: nCu~I~~r for the Oreb~Wi,Jtility Notificalion S~de I Setbac~:' 180 DAY PERIOD. # Street T.rees Rqd: Center is 1-lM'9-<9S!!.pps4l\), SIde 2 SetbacR:NY Paved Drive Rqd: Compact: 'Rearyard Setback: % of Lot Coverage: Solar Setbacks: E # of Stories: Height of Structure Type of Heat: Water Type: RangeType: Energy Path: Sprinkled Building: 403,801 51,598 # of Units: Primary Occnpancy Group: Secondary Occnpancy Group: Primary Construction Type Secondary Construction Type: . # of Bedrooms: lIB . IPUBLIC IMPROVEMENTS, Street Improvements: Storm Sewer Available: Special Instruction: ~~ 'P\' l\ ,~ (j O~ \\.,~ . \, \j:1" . Sidewalk Type: Downspouts/Drains: >' Notes: Pae:e I of 6 Status Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line Description . Estimate Type of Construction Estimate Fee Description Plan Review Comm/Ind/Public Plan Review Fire & Life Safety + 10% Administrative Fee + 12% State Snrcharge + 5% Technolngy Fee Temp Power 200 amps or less + 10% Administrative Fee + 12% State Surcharge + 5% Technology Fee Minimum/Adjustment Electrical -Mech Iss 2+ Appliances~ + 10% Administrative Fee + 12% State Surcharge + 5% Technology Fee Air Handling Unit 10,000 & Ovr Backflow Device Boi1er/Comm 30-50.HP Boiler/Comp Up To 100,000 btu Building Permit Dryer Vent Evaporative Coolers Exhaust Hoods Fire SF Fee - Non-Residential Fixture Gas Outlets 1-4 Gas Outlets 4+ Miscellaneous Plumbing Not Covered Mechanical Sanitary Sewer - 1st 50 Feet Sanitary Sewer Each AddtllOO' Storm Sewer - 1st 50 Feet Storm Sewer Each Addtl100' Thermal Unit Vent Fan Water Line - 1st 50 Feet Water Line - Each Addtl.IOO' I Valuation Description I $ Per Sq Ft , or mnltiplier ' $1.00 Square Footage or Bid Amount 10,783,928,00 Total Value of Project Fees Pairl I Amount Paid $25,266.51 $15,548.62 $5.50, $6,60 $2.75 $55,00 $2,10 $2.52 $1.05 $21.00 $40.00 ' $4,822.94 $5,168.35 $2,153.48 $85,00 $48.00 $147.00 $42.00 $38,871.56 $7.00 $20.00 $20,00 '$5,159.80 $2,736.00 $5,00 $6.00 $150.00 $100.00 $50,00 $32,00 . $50.00 $480.00 $300,00 $42.00 $50.00 $128,00 Date Paid 4/1/08 4/1/08 6/9/08 6/9/08 6/9/08 6/9/08 6/11/08 6/11/08 ,6/11/08. 6/11/08 6/12/08 6/12/08 6/12/08 6/12/08 6/12/08 6/12/08 6/12/08 6/12/08 6/12108 6/12/08 6/12/08 6/12/08 6/12108 6/12/08 6/12/08 6/12/08 6/12/08 6/12/08 6/12/08 6/12/08 6/12/08 6/12/08 6/12/08 6/12/08 6/12/08 6/12/08 Pae:e 2 of 6 CITY OF SPRINGFIELD Building/Combination Permit PERMIT NO: COM2008-00438 ISSUED: 06/12/2008 APPLIED: 04/01/2008 EXPIRES: 07/291i009 VALUE: $ 10,783,928.00 Value Date Calcnlated $10,783,928:00 $10,783,928.00 04/01/2008 Receipt Number 2200800000000000382 2200800000000000382 2200800000000000850 2200800000000000850 2200800000000000850 2200800000000000850 1200800000000000640 1200800000000000640 1200800000000000640 1200800000000000640 1200800000000000647 1200800000000000647 1200800000000000647 1200800000000000647 1200800000000000647 12008000000000~0647 1200800000000000647 1200800000000000647 1200800000000000647 1200800000000000647' 1200800000000000647 1200800000000000647 1200800000000000647 1200800000000000647 1200800000000000647 1200800000000000647 1200800000000000647 1200800000000000647 1200800000000000647 1200800000000000647 1200800000000000647 1200800000000000647 1200800000000000647 1200800000000000647 1200800000000000647 1200800000000000647 Status Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line + 10% Administrative Fee + 12% State Snrcharge + 5% Technology Fee Add, Alter, Extend Circ Ea Add Low Voltage - Commercial Indus Perm Serv/FdrlOOO amps/volts Perm Serv/Fdr 200 amps or less Perm Serv/Fdr 201 to 400 amps Perm Serv/Fdr 601 to 999 amps + 10% Administrative Fee FLS Safety Systems Review + 12% State Surcharge + 5% Technology Fee Sign - On.tIine Lighting Each + 12% State Surcharge + 5% Technology Fee Low Voltage - Commercial Indns Total Amount Paid Fire Department Review 12/12/2008 Initial Review 04/02/2008 Initial Review 04/15/2008 Structural Review 04/15/2008 Plannine: Review 04/15/2008 Public Works Review 04/15/2008 Fire Department Review 04/15/2008 SUB Review 04/15/2008 CITY OF SPRINGFIELD Building/Combination Permit PERMIT NO: COM2008-00438 ISSUKD: 06/1212008' APPLIED: 04/01/2008 EXPIRES: 07/29/2009 VALUE: $ 10,783,928.00 $389.90 $467.88 $194.95 $1,352.00 $100,00 $413,00 $1,190.00 $664.00 $180,00 $52,80 $528.00 $7.56 $3.15 $63.00 $6,96 $2.90 $58,00 8/1/08 8/1/08 8/1/08 8/1/08 8/1/08 8/1/08 8/1/08 8/1/08 8/1/08 12/3/08 12/3/08 1/28/09 1/28/09 1/28/09 , 1130/09 1/30/09 1/30/09 $107,299.88 I Plan Reviews I 04/08/2008 WE LLH , 04/15/2008 APP LLH 04/25/2008 WE LLH 05/06/2008 APP SPH 05/06/2008 APP JHJ OS/25/2008 OK GRG OS/28/2008 APP JF Pa!!e 3 of6 1200800000000000832 1200800000000000832 1200800000000000832 1200800000000000832 1200800000000000832 1200800000000000832 1200800000000000832 1200800000000000832 ' 1200800000000000832 3200800000000000775 3200800000000000775 3200900000000000045 3200900000000000045 3200900000000000045 1200900000000000063 1200900000000000063 1200900000000000063 Fire Protection New plans will be subniitted - do not process Plans resubmitted 4/14/08 and routed 4/15/08 Letter mailed to Dave Gnadagni with Robertson Sherwood Architects from Mick Nolte with the Building Department under contract with the City of Springfield asking for resolution or acknowledgement prior to permit issuance, See . attached documents, To be constructed per approved , Final Site Plan DRC2007-00075. Attached SDC Worksheet. No New SDC's,. (JHJ) See attached document for Fire Department Plans Review comments. Energy Review approved. See attached documents. CITY OF SPRINGFIELD' Building/Combination Permit PERMIT NO: COM2008-00438 ISSUED: 06/12/2008 APPLIED: 04/01/2008 EXPIRES: 07/29/2009 VALUE: $ 10,783,928.00 Status Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line Structural Review 06/02/2008 06/06/2008 APP LLH Plan Review Comments 07/29/2008 07/29/2008 10 LLH Fire Department Review 12/03/2008 12/03/2008 APP GRG Initial Review 12/12/2008 12/12/2008 APP LLH Plans reviewed by Mick Nolte at the Building Department under contraCl with the City of Springfield, See attached documents for plan review response from Dave Guadagni, Robertson/Sherwood Architects. See attached documents for fax sent to John Saraceno with Springfield School District asking for electrical permit fees. ' See attached document for Fire Department Plans Review comment, for fire alarm system. Received plans for Fire Protection. Routed to Gilbert Gordon for review. To Request an inspection call the 24 hour recording at 726-3769. All inspections requested before 7:00 a.m. will be made the same working day, inspections requested after 7:00 a.m. will be made the following work day. I Reouired Insnections I . , SUB Insulation Vapor Barrier: To be called for at the same ti'me as the SUB framing inspection. SUB Final: After all required energy inspections have been reqnested and approved. SUB Mechanical: Following City Rough Mechanical inspection approval and prior to any cover, SUB Ceiling Grid: Interior Lighting SUB Exterior Lighting Site Inspection: To be made after excavation but prior to setting forms. Ufer Electrical Ground: Install ground rod at footing and call for inspection in conjunction with footing and/or foundation inspection. Footing: After trenches are excavated, Foundation: After forms are erected but prior to concrete placement. Slab: To be made after all inslab building service equipment, conduit piping and other equipment items are in place but prior to concrete. Shear Wall Nailing: Before covering sheathing with finish materials. Framing Inspection: Prior to cover and after all rough in inspections have been approved, Roof Sheathing Pae:e 4 of6 CITY OF SPRINLi.t<1J'.LU Building/Combination Permit Status Issued PERMIT NO: COM2008-00438 ISSUED: 06/12/2008 APPLIED: 04/01/2008 EXPIRES: 07/29/2009 VALUE: $ 10,783,928.00 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line Drywall: Prior,to taping. 'Firewall: Located and constructed according to plans. Masonry: Underslab Plumbing: Prior to filling the trench and including required testing. Underlloor Plumbing: Prior to insnlation or decking. Rough'Plumbing: Prior to cover and including required testing. Water Line: Prior to filling trench and including required testing, 'Sanitary Sewer Line: Prior to filling trench and including required testing. Storm Sewer Line: Prior to filling trench. Backllow Device: Prior to covering and provide a copy of the test report on site at the time of inspection, Underslab Gas: After line is installed and required testing and capped if not attached to an appliance. Underlloor Gas: After line Is installed and required testing and capped if not attached to an appliance, Underl100r Mechanical. Prior to insulation or decking and including required testing, Rough Gas: After line is installed and required testing and capped if not attached to an appliance. Gas Service: After line is installed and line has been connected to a minimum of one appliance including required testing. Presure test done at this point. Rough Mechanical: ,Prior to Cover Final Gas: When all gas work is complete, Final Mechanical: When all mechanical work is complete, Final Plumbing: When all plumbing work is complete. Final Fire Department. After all requirements of the Fire Department have been met, Final Building: After all required inspections have been requested and approved and the building is complete, Temporary Electric: Approval required prior to Utility Company energizing pole. Sign Electrical: After connection is made but prior to energizing Low Voltage: Prior to cover. Pae:e 5 of 6' Status Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-37691nspection Line ~ CITY OF SPRIN\JI'lJ'.LD ' Building/Combination Permit PERMIT NO: COM2008-00438 ISSUED: 06/12/2008 APPLIED: 04/0112008 EXPIRES: 07/29/2009 VALUE: $ ]0,783,928.00 By signature, 1 state and agree, that I have carefnlly examined the completed application and do hereby certify that all information hereon is true and correct, and I further certify that any and all work performed shall be done in accordance with the Ordinances ofthe City of Springfield and the Laws of the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made of any structure without permission of the Community Services Division, Bnilding Safety. 1 further certify that only contractors and employees who are in compliance with ORS 701.005 will be used on this project. I further agree to ensure that all required inspections are requested at the proper time, that each address is readable from the street, that the permit card is located at the front of the property, and the approved set of plans will remain on the site at all times during .construction. Owne~ or Contractors Signature , Page 6 of6 Date 'City of Springfield Electrical Authorization To Begin Work E-mailedTo:jilll@vyanet.com Receipt # ',RC545998 1/29/20093:21:01 PM Check on status of permit By Phone: (541)726-3753 or Email: permitcenter@ci.springfield.or.us 10 1 or 2 family dweJling o Multi-family W Commercial I Industrial I ],000 sq. ft. or l~ss [4) -I Ea. add! 500 sq. ft. or portion 1,0 New construction o :\dditioOJalterationlreplacement IJobno.: IJobaddress: 2109 1ST ICity/StatelZlP: ~PRINGFIELD"OR 97477-4334 I SuiteJbldg./apt.no.: I Project name: Cross street/directions to job site: 1 Lot no,: . - Limited energy, residential (with above so. ft.) I - Limited'energy, multifamily residential (with above so: 1'1.) I-Limited energy, commercia-] (with above sa. ft) I - Stand-alone limited energy, residential I - Stand-alone limhcd energy, multi~familv - Stand-alone limited energy, commercial [,~'s~.~ISl2,!3J:~!~~ts1[~~2jYerjl"tiIf~!,i~:.rr~~9~1!l~li~~~~ I 1 not offered online at this jurisdiction I SUbdivision: ITax map/parcel no.: 1703361200100 $32,00 $32,00 SECURlTY SYSTEM I 1401 amps to .599 amps [2] l ~tEM~'ORARY'serv-icestbR1fccdcrs1insfaiilitiomltcration, ~WJ?J,9P~I~1~i!~~~~?~,' LOW VOLTAGE 200 amps or less [2J 1201 amps to 400 amps [2J lEI. lie. no.: 20-476CLE ICCBlic;'no;: 15661? I Business Name: ST SECURETECH INC Contact: 156618 , IAddress' 6286 FER~~~~'r:: ' 1 Gty/S'.tclZIP, SP~?:P~,\f~11'4~.^1'- I:VDIRI: I~ TI-lF WORK IPho~e: (541)521283;~:..;-:-: :8~:2~!} ~~!r~X~~~ DJ:~MIT I~ Nor IEmail: ~i1l1@vyanet.;~;;\/~~~~~~~~::8 8n !: .'^_~_^_~Ig.r:'MJ:n ~nR ) Metro he. no.: ,'_:\' ; 88 r::;~~1 ;,!:n~5~. he. no.: I Supervising electrician's Iic: no.: 3295LEA I Supervising elect~ician's name: RON GERMAN 200 amps or less [2] 120] amps to 400 amps [2] )401 amps to 599 amps [2] ItBm~ilrtirtuftS;;NE'V.+aITetair~n';10R1extbnsio~per;panel':$t:~.~;1,~r_::1 ,,' _.!X%tt..=~,.~.".,,.......~"l"'~""_""~,,,'A...'c:""~:==t,vM'iMi"-""'c.-'..,,'~,,_,-,,,_'-, "_. "'. '.~. I A. Fedor br,anCh circuits with I service or, feeder fee, each branch cirCUIt " I B: Fee for branch circuits I I without service or feeder fee, . . ' I1rstbranchcircuit 21 . _ . _.' .._. ',-"''''i;;'''I;l;,nl'."J ''''gon "" I ",yu"~'r ,,,~ 13 I r:acn.aaa .DrnnC11'CJ~CU)[. ,.. _ ('\..,..,......1, Iltilih, I ~'I.I""~I.""C""e:\i!J. "",uJ,pt"'.,,;"'i4J#%;iri' . "'.' , ~'~' "."1 IScel.aneou"T ."l:'''~''''''''''-.:'i_i/C:,;'.i ;=.~ "=".,,. ",," ."" .j ; '.~:="-~""*iV0'!'''''';~'''~T.~'^~''''I':l.:~i1tl~J;:Sr:_..;.~fFi;..... .,~ I' ~ (s.liiYii?ikF4~~'(5qnFrlthlh;r "nh OAR 952-001 1 "~~cfi'~~nU~lfctu~d,ofmodurlrrco )ies of th ~ rules b~ I o ;V;;umg~e~ndlo'lfi\ld" I h 1 1;l],lIln"! Ih" r.Anter, (No' e' the te lp one 1 1.I',l\l)WI~~r"&!~~!l'~!~~o~']Jon 'lJtil~ty NOfl1lCiillUII 1 I I SIgn or ouW~'lig1ltlOg [2J-tlUU-. ~;j~ c.vLtLt~. I 1 Signal circuit(s) or li.mited~ I alteratIOn, or I Name: JEFF @HYLANDCONST I Phone: (541) 726-0635 I Email: IF." Upon review and approval by_your local Jurisdiction, your permit will be"e~mailed or faxed within one business day, with instructions on how to schedule your inspection. Subtotal Minimum fee used instead of Subtotal State Surcharge (12% of perin it fee) City Of Springfield fees. I TOTAL PERMIT FEE I . City Of Springfield fees: 5% Technology Fee . CIu~n43~,p:";O~J_ $32,00 I $58,00 I $6,96 I $2,90 I $67,86 I NOTE: This Authorization To Begin Work expires within 180 days if a permitis not obtained. The local building department may determine that an Authorization To Begin Work is null and void if it does not meet applicable land 'use laws and local ordinances. 1130lcq This Autliorization To Begin Work must be posted at the job,site until replaced by a Permit 225 Fifth Street Springfield, Oregon 97477 541"726-3759 Phone Job/Journal Number COM2008-00438' COM2008-00438 COM2008-00438 Payments: Type of Payment ONLINE CHGS cReceintl RECEIPT #: City of Springfield Official Receipt Development Services Department Public Works Department 1200900000000000063 Date: 01130/2009 Description Low Voltage - Commercial Indus + 5% Technology Fee + 12% State Surcharge Paid By ONLINE PERMIT CHGS Item Total: Check Number Authorization Received By Batch Number Number How Received kr ONLINE securetech Online Payment Total: Page 1 of 1 8:21:02AM Amount Due 58,00 2.90 6.96 $67,86 Amount Paid $67.86 $67,86 1/30/2009