Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 2009-1-9 l.. ~;, Infonnalion "''''.l1b Build On Engineering. Consulting. Testing c~- \'2-{1~ DAILY FiELD REPORT Date Performed: January 9, 2009 Report Number: 722-80276-15 Client: Ms, Lauretta Davies Project Name: J,,' .:0...... ;*) Jerry's Home Improvement provements P.O. Box 2611 Project Local' 2525 Olympic Street Eugene, Oregon 97402 Springfield~egOn .... ., P,O, No.: Z4175LD Type of Inspection: Welding Weather: Inside Field Observations and Comments I Performed continuous visual inspection of the following items at Gibson Steel Fabrication shop: Four (4) TS 8 x 6 x 5/16' Column base plates and brackets for horizontal beam. Fit-up of weld joints were inspected for workmanship, In, progress welding was monitored to the fabricators FCAW welding procedure specifications, Weldments were inspected for size, length, profile and locations, To the best of our knowledge, the work inspected was in accordance with the building department approved design drawings, specifications and applicable workmanship provisions of the AWS D1,1 Code. Inspector: David Smith 0877340-85 CCB #176269 If you have any questions regarding this report, please feel free to contact us at 541-746-9649, Respectfully Submitted, ~ro._. :rfr""." M Branch Manager c: City of Springfield Chambers Construction - David Bakke Robertson Sherwood Architects - Scott Stolarczyk Metzler Engineering, Scott Metzler THIS REPORT 1$ PROVIDED FOR THE INFORMATION OF THE CLIENT aNL y, THE REPRODUCTION OF THIS REPORT. BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD PARTY, BY ANY MEANS,.EXCEPT IN FUlL WITHOUT THE WRITTEN PERMISSION OF PROFESS/ONAL SERVICE INDUSTRIES, IS PROHIBITED. Professional Service Industries, tnc.. 104Q-A Shelley Street. Springfield, OR 97477 . Phone 541/746.9649 . Fax 541/746-7163 I... ~ ;ZInformation ,,~. .10 Build On Engineering. Consulting. Testing eB- IfJq5 DAILY FIELD REPORT Date Periormed: January 9, 2009 Report Number: 722-80276,14 Client: Ms, Lauretta Davies Project Name: Jerry's-McKenzie Field Jerry's Home Improvement Improvements P.O, Box 2611 Project Location: 2525 Olympic Street Eugene, Oregon 97402 Springfield, Oregon P,O, No.: Z4175LD Permit No.: Contractor: Chambers Construction Weather: Overcast Type of Inspection: Reinforcing Steel Field Observations and Comments Performed visual inspection of reinforcing steel at the following locations: Concrete slab on grade for the proposed ne\,\, Lumber Yard, Reinforcing steel was secured using tie wire and will be supported on concrete dobie blocks during placement of concrete, To the best of our knowledge, the work inspected above was in accordance with the building department approved design drawings, specifications, and applicable workmanShip provisions of the International Buiiding Code, Inspector: Steve Wilder CCB# 176269 If you have any questions regarding this report, please feel free to contact us at 541'746-9649, RespectfUlly Sub 1)ssional s~ David~ Branch Manager c: City of Springfield Chambers Construction, David Bakke Robertson Sherwood Architects - Scott Stolarczyk Metzler Engineering - Scott Metzler , THIS REPORT IS PROVIDED FOR THE INFORMATION OF THE CLlENT.QNL Y. THE RE,PRODUCTlON OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD PARTY, BY ANY MEANS, EXCEPT IN FULL, WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES, IS PROHIBITED. Professional Service Industries, Inc. . 1040-A Shelley Street. Springfield, OR 97477. Phone 541(746-9649 . Fax 541/746.7163