Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 2009-1-6 CB-5-tt:l l...~ ;ZInjonnation ",~. .To Build On Engineering. Consuttlng . Testing DAJL Y FIELD REPORT Date Performed: January 6, 2009 Lee Construction PO Box 10367 Eugene, OR 97401 Report Number: 722,80177-48 A3 - Academy of Arts & Academics 615 Main Street Springfield, Oregon Client: Project Name: Project Location: Contractor: Type of Inspection: Lee Construction Welding Shop/Field: Weather: Field Overcast Field Observations and Comments 'Performed periodic visual inspection of the following items: Mezzanine deck puddle welds and putton punch, Weldments were inspected for size, length, profile and locations (attached), To the best of our knowledge, the work inspected is in conformance with approved drawings, specifications and applicable D1,1 codes, except for the following, Inspector: David F Smith, Certification #0877340-85 CCB #176269 If you have any questions regarding this report, please feel free to contact us at 541-746-9649, Respectfully Sfe~itted, .i)~, r~rm"'I" David Smith Branch Manager cc: City of Springfield Branch Engineering Sol arc Architecture Professional Underground Service Springfield School District - John Saraceno THIS REPORT IS PRovrOEO FOR THE INFORMATlONOF THE CLIENT ONL Y. THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRo PARTY, BY ANY MEANS, EXCEPT IN FULL, WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES, IS PROHIBITED. Professional-Service Industries, Inc. . 1 040-A Shelley Street. Springfield, OR 97477 . Phone 541 f7 46-9649 . Fax 541f7 46-7163 l rta ~;lInformation ,.,~. .10 Build On Engineering. Consulting. Testing C',h-545 DAfL Y FIELD REPORT Date Performed: January 9, 2009 Lee Construction PO Box 10367 Eugene, OR 97401 Report Number: 722,80177'49 A3 ' Academy of Arts & Academics 615 Main Street Springfield, Oregon Client: Project Name: Project Location: Contractor: Type of Inspection: Lee Construction Welding Shop/Field: Weather: Shop Fog Field Observations and Comments Performed periodic visual inspection of the following items: (2) columns ASI 65 fillet welds top and bottom plates. Weldments were inspected for size, length, profile and locations (attached), To the best of our knowledge, the work inspected is in conformance with approved drawings, specifications and applicable 01,1 codes, Fabricator was asked to notify our office when additional services are needed. 'Inspecior: David F Smith, Certification #0877340-85 CCB #176269 If you have any questions regarding this report,. please feel free to contact us at 541,746,9649, Respectfully Su mitted, i)~: -ir""~' David Smith Branch Manager cc: City of Springfield Branch Engineering Solare Architecture Professional Underground Service Springfield School District, John Saraceno THIS REPORT IS PROVIDED FOR THE INFORMA TION OF THE CLIENT ONL Y THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD PART'/'. BY ANY MEANS EXCEPT IN Fill / WIT/.inIIT THF WRITTFN PFRhAI<:;<:;/nM nr: oo,"",eN',C'."" ('cn,,,,...,...- '''Q!,.'l;"T"q'!:f, 'f "''1G;''-'~~~. Professional Service Industries, Inc. . 1 040-A Shelley Street. Springfield, OR 97477. Phone 5411746.9649 . Fax 541/746-7163