R-VALUE
NO. OF BAGS PER
1,000 SQ. FT. NET AREA
To obtain a
Thermal Resistance
(A)af:
60
'9
4'
38
30
26
22
19
13
11
No.ofBags
36.5
29,6
26.4
22.8
18.0
15.5
13.1
11.1
7,7
6,6
iJ-~~
MAXIMUM
NET COVERAGE
Conlentsofbag
should not cover
more lhan: (sq.tt.)
27
3'
38
44
56
65
77
90
129
151
tarn 2...lSblo - b 1 OD3
InsulSafe@4
Premium Blowing Wool
k()k~~V1 d
Company Name
Company Name
MINIMUM
WEIGHT
Weight per sq. ft. of
installed insulation should
not be less than: (Ibs.lsq. ft.)
0.986
0,800
0.712
0.615
0.485
0.418
0.353
0.301
0.209
0.179
INITIAL INSTALLED
THICKNESS
Should not be
lesslhan
(in.)
22.00
18.50
16.75
14.75
12.00
10.50
9.00
7.75
5,50
4.75
A-VALUE THICKNESS AREA (SQ. FT.) InsulSafe o/(tI)
38 /</'11<1 ISo () V
CEILINGS 30/38 300/~O6
I
WALLS 2.3od I
,;(1
FLOORS -
.2~ -z.. '2-- () cl
BAGS USED
.35
1'-~ 1-07
Date
Date
Date
MINIMUM SETTLED
THICKNESS
Should not be
less than:
(in.)
22.00
18.50
16.75
14.75
12.00
10.50
9,00
7,75
5.50
4.75
BA7S'V)
/
1/
/
THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION
. In accordance with the chart above, you must install the minimum number ot bags per 1,000 sq, ft. ot net area tor each
R,Value listed.
. The maximum net coverage must not exceed that specified for each R-Value.
. The installed insulation must be at or above the specified minimum thickness for each R-Value.
Failure to install the required minimum weight per sq. ft. of insulation at or above the minimum thickness will result in
reduced R,Value,
. This product sh'ould not be mixed with other blown insulations or the thermal claims will become invalid,
. Initial installed thickness testing per ASTM C 1374 using Unisul VoluMatic III; 3rd gear; 16,inch gate opening;
150-tt x 3-1/2 inch-diameter internally corrugated blowing hose,
R-Values are determined in accordance with ASTM C 687 and C 518, Complies with ASTM C 764 as Type 1 insulation.
"R" means resistance to heat flow. The higher the R,Value, the greafer the insulating power. To get the desired
R,Value, it is essential that the insulation is installed properly,
DANGER: RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ONTOP OR WITHIN 3" OF SUCH
DEVICES, DOES NOT APPLY TO TYPE IC LIGHT FIXTURES ORTO FLUORESCENT FIXTURES WITH THERMALLY
PROTECTED BALLASTS,
30-24-233 InsulSafe@4 Builders Statement
A Saint-Gobain Company
@200SCertainTeedCorporation 11/05
Manufacturer Insulation Fact Sheet
This is Certain Teed Corporation Ins u I Safe@ 4
Premium Blowing Wool
Certain Teed Corporation
P,Q. Box 860
Valley Forge, PA 19482
THERMAL PERFORMANCE-HORIZONTAL OPEN BLOW
Th" following thermal performances are achieved at weights and coverages specified when insulation is installed with
pneumatic equipment in a horizontal open blow application:
NO. OF BAGS PER MAXIMUM MINIMUM INITIAL INSTAllED MINIMUM SETTLED
A-VALUE 1,000 SQ. FT. NET AREA NET COVERAGE WEIGHT THICKNESS THICKNESS
. To obtain a Contents 01 bag Weighl per sq. ft. of Should nolbe Should not be
Thermal Resistance No. of Bags should not cover installed insulalionshould lesslhan: lesslhan:
(R) or more than: (sq. ft.) nOlbe less than: (lbsJsq.ft.) (in.) (in.)
60 36,5 27 0,986 22,00 22,00
49 29,6 34 0,800 18.50 18.50
44 26.4 38 0.712 16,75 16,75
38 22,8 44 0,615 14,75 14,75
30 18,0 56 0.485 12,00 12,00
26 15,5 65 0.418 10,50 10,50
22 13,1 .77 0,353 9,00 9,00
19 111 90 0,301 7,75 7,75
13 7,7 129 0,209 5,50 5,50
11 6,6 151 0,179 4,75 4.75
'-
R-values are determined in accordance with ASTM C 687 and C 518, Complies with ASTM C 764 as Type 1 insulation.
THERMAL PERFORMANCE-SIDEWALL RETROFIT APPLICATION
When installed with pneumatic equipment in sidewalls, the following thermal performances are achieved at the
thicknesses, weights and coverages specified, Based on a design density of 1,6 pcf/25,6 KglmJ
NO. OF BAGS PER MAXIMUM MINIMUM INITIAL INSTALLED MINIMUM SETTLED
R.VALUE 1,000 SQ. FT. NET AREA NET COVERAGE WEIGHT THICKNESS THICKNESS
To obtain a Contents 01 bag Weight per sq. It. 01 Should not be Should not be
Thermal Resistance No. of Bags should notcQver installed insulation should less than: less than:
(R)ot more than: (sq.lt.) nolbe lesslhan: (Ibs./sq.lt.) (in,) (in.)
29 35,8 28 0,967 7,25 7,25
22 27,2 37 0,733 5,50 5.50
16 19,8 51 0,533 4,00 4,00
15 17,9 56 0.483 3,625 3,625
14 17,3 58 0.467 3,50 3.50
BEAn THIS REFORE YOU BUY
What you should know about R-Values:
The chart shows the R-Value of this insulation, R means resistance to heat flow, The higher the R.Value,
the greater the insulating power. Compare insulation R-Values before you buy,
There are other factors to consider. The amount of insulation you need depends mainly on the climate
you live in, Also, your fuel savings from insulation will depend upon the climate, the type and size of your
house, the amount of insulation already in your house, and your fuel use patterns and family size, If you
buy ,too much insulation, it will cost you more than what you'll save on fuel. '
To get the marked R-Value, it is essential that this insulation be installed properly.