Loading...
HomeMy WebLinkAboutPermit Geo-Tech Report 2009-1-8 ~"''''l ~r."',. ., ..... Page 1 of 1 11a.'II~lri,"11io':iI~'ll'I~.IU" Geotechnical & Coostruclion Servires Daily Field Report . Client: EWEB Project: Hayden Bridge Water Filtration Date: 01-08-09 500E. 41h Ave. Plant Expansion Project No,: 2087168 Eugene, Oregon Springfield, Oregon Report No,: E-22132 Inspector: A. Fenstermacher 10 No,: 5258882-49 ICC Inspection of: Reinforced Concrete Weather: Showers Continuous Inspection: 0 Contractor: Wildish Bu\lding Co. SP No~: .2008-00225 Periodic Inspection: I!'J Performed final inspection on.the reinforcing steel for remaining ramp walls (except west end); baffle wall north of wall #29, wall #21. Preliminary inspections were performed on 12-23-08 and 01-07-09 (reference FEI reports E22072 and E22123). Observed the placement of 40 yards of Knife River 4000 psi concrete (mix 40-SE7) into areas noted above. Concrete was placed by pump and was mechanically consolidated. Performed fieid tests on load 1 to verify mix design compliance: concrete temperature- 65F; Air teinperature- 49F; slump- 7 1/2": air content- 5:5%. Cast one (1) set of four (4) 4" x 8" compressive strength cylinders. Notified Jake Stucky (Wildish) and Mike Stickling (EWEB) of on-site test results: concrete temperature- 64F; air temperature- 52F; siump- 6"; air content- 4.6%. Mr. Stucky was asked to notify our office when additional services are needed. To the best of our knowledge, the work inspected was in accordance with plans.dated 0212008 and applicable workmanship provisions of the I.B.C., except if noted above. Reviewed By: A, '1(. tfJu.,_ Michael L Me(;r Technical Manager c: EWEB- Mike Slickling (email) EWEB- Wally McCullough (email) OBEC- Pele Siocum (email) Wildish Building Co.- Kevin Fitzjarrell (email) Wildish Building.Co.- Jake Stucky (em ail) City of.Springfield R~Cf::: J4;j! . Ij/~/' J (J" . /(}(}U MLM:sc This report and/or enclosed test data ;s the confidential property of the client to whom it is addressed and pertains to the specific process and/or material evaluated. As such, information contained herein shalt not be reproduced in part or'full and/or any part thereof be.disclosed without FEI Testing & Inspection, Inc.'s written authorization. 700 NN Cornell Avenue' eavanis, Qegoo 97330, phone (541) 757-4698' fax (541) 757-2991 29540 BAirport Road, Eug€ne, Qegoo 97402 . ptxlne (541) 684-3849 . fax (541)684-;)851 63050 Corpcrate Place, Suite 2 . Bend, Oregon 97701" phone (541) 382-4844 . fax (541) 382-4846 .A1Pp., ~rt 11~'III[rUII~~'lU'llmgIHCi CLIENT EWEB 500E. 41h Ave. Eugene, Oregon DATE CAST ' STRENGTH REQUIRED STRENGTH PLACED PRODUCT CODE ADDITIVES LOAD NO. CONC~ETE TEMP AIR TEMP POURLOCATION LOAD 1 SAMPLED GeOtechnical & Construcfun Services Compressive Strength of Concrete (ASTM C 39) PROJECT DATE PROJECT NO. REPORT NO. 01-08"09 2087168 6145 Hayden Bridge Water Filtration.Plant Expansion Springfield, Oregon B.P.NO. 2008-00225 CAST BY 12-12-08 4" x8" Knife River 314" 4.5% 5" 11:20 AM ASTM C31 A. Fenstermacher DATE RECEIVED SPECIMEN SIZE SUPPLIER MAX SIZE AGG. AIR CONTENT SLUMP TIME SPECIMEN STORAGE 12-11-08 4000 psi 4000 psi 40-SE7 Super; Eclipse 1 TICKET NO. 3160554 610 F YARDAGE 7.5 OF 500 F WEATHER F09 Ramp footings, north and south (up to SUMP). SACKS CEMENT 22.0 From south footing near west end. REMARKS: Jake Stucky (Wildish) was advised of on-site test results. Reviewed By: (1}'~e:r Technical Manager c: EWEB-Mike Stickling (email) EWEB- Wally McCullough (emaii) OBEC- Pete Slocum (email) Wildish Buiiding Co.- Kevin Filzjarrell (email) Wild ish Buiiding Co.- Jake Stucky (email) City of Springfield Knife River MLM:sc This report and/or enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part thereof be disclosed without FEI Testing & Inspection, Inc.'s written authorization. 700 NVV ComeIIAvenue' CorvaI6s, Oregon 97330' phooe (541) 757-4698 'lax(541) 757-2991 29540 B Airpat Road . Eugene, Oregon 97402 . phone (541) 684-3849 . lax (541) t3Il<k3851 63050 Corporate Place, Suite 2 . Bend, Oregon 97701 . phone (541) 3824844 . fax (541) 382-4846 ~fE) Geotechnical & Construction Services 11~111~{rtallllJ.'~~'I(II~IIIIH. CLIENT PROJECT EWEB 500E. 4th Ave. Eugene, Oregon B.P,NO. DATE CAST' STRENGTH REQUIRED . STRENGTH PLACED PRODUCT CODE ADDITIVES LOAD NO. CONC~ETE TEMP AIR TEMP POUR LOCATION 12-12-08 CAST BY 4000 psi 4000 psi SACKS 40KIVOZF CEMENT . ADV A; Eclipse: Fiber 1 TICKET NO, 5r F YARDAGE 420 F WEATHER Slab #7. LOAD l' SAMPLED "From center. Compressive Strength of Concrete. (ASTM C 39) Hayden Bridge Water Filtration Plani Expansion Springfield, Oregon '2008-00225 A. Fenstermacher 3160586 9.0 OF 26.0 Rain DATE PROJECT NO. REPORT NO. 01-09-09 2087168 6146 12-13-08 4" x 8" Knife River 314" 5.0% 4114" 11:30AM ASTM C31 AVERAGE TEST AGE AREA WEIGHT TOTAL COMPRESSIVE STRENGTH TIME OF TYPE OF DATE (DAYSl (IN.'l (LBS) LOAD (LBSl STRENGTH (PSI) (PSI) TEST FRACTURE~ 12-19'08 7 12.56 8.4 59000 4700 10:50 AM 6 o 1-09~09 28 12.56 8.4 78100 6220 7:30 AM 5 01-09-09 28' 12.56 8.4 77800 6190 6205 7:35 AM 5 Hold **1_ End Cones 2 ~ Cone/Split 3 -Columnar . 4 - Di~gonal 5- Side (top and bottom) 6 - Side (top or bottom) REMARKS: Jake Stucky (Wildish) was advised of on-site test results. Reviewed By: //1. 'h.~ MichaelL. MeyW Technical Manager c: EWEB-Mike Stickling (email) EWEB-Wally McCulloU9h (email) OBEC- Pete Slocum (email) Wildish Building Co.- Kevin Fitzjarrell (email) WildishBuilding Co." Jake Stucky (email) City of Springfield Knife River MLM:sc DATE RECEIVED SPECIMEN SIZE SUPPLIER MAX SIZE AGG. AIR CONTENT SLUMP TIME SPECIMEN STORAGE This report and/or enclosed tes~ data is the confidential"property of the client to whom it'is.addressed"and pertains to the specific process and/of material evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part thereof be disclosed without FEI Testing & Inspection, Inc,'s written authorization. 75] r-NV Coo1eI/Avenue' Cavallis,Oeg:n 9733O. phone (541) 757-4698, fax (541) 757-2991 29540 B Airpa1 Rood . Eugene, Oeg:n 97402. phone (541)684J849' fax (541 )6lJ4.3851 63050 CorporatePlace, Suite 2 . Bend, Oregon 97701 . phone (541) 382-4844 . fax (541) 382-4846 ~ftl Page 1 of 1 11;"'llllrl~I~.'~~.llll~_ Ccvb.;',,1ica1 & Cons1ruction SeMces Daily Field Report Client: EWEB 500E. 4th Ave. Eugene, Oregon Project: Hayden Bridge Water Filtration Plant Expansion Springfield, Oregon Date: Project No,: Report No.: Inspector: 10 No,: 01-07-09 2087168 E-22123 A. Fenstermacher 5258882-49 ICC Inspection of: Reinforcing Steel Contractor: Wildish Building Weather: _. Overcast . BP No,: 2008-00225 - . . Continuous Inspection: 0 Periodic Inspection: Ii:! Performed preliminary inspection on the reinforcing steel for wall numbers 20, 21; 'baffle wall north of number 29: elevated slab above wall number 23. Reinforcing steel was checked for size, grade, laps, quantities, localions, ties, clearance and supporls. A final inspection will be performed prior to concrete placement To the best 0.1 our knowledge, the work inspected was in accordance with memo dated 10-17-08, plans dated 0212008 and applicable workmanship provisions of the LB.C., except if noted above. Reviewed By: j1J, 7i, ~ ___ Michael L ~eyer Technical Manager c: EWEB- Mike Stickling (em ail) EWEB- Wally McCullough (email) OBEC- Pete Slocum (email) Wildish Building Co.- Kevin Fitzjarrell (em ail) Wildish Building Co.- Jake Stucky (email) Cily of Springfield This report and/or enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part thereof be disclosed without FEI Testing & Inspection, Inc.'s written authorization. 1>- ~'1 ~ ',. "1' ..../ ./ ,. if <'/ 1J. ~ MLM:sc 7ffJ NW ComeIlA'Mlue' Corvalr~, CXegon 97330, phone (541) 7574698, fax (541) 757-2991 29540 B Airpat Road . Eugene, CXegon 97402 . phone (541) 684-3849 . fax (541 )6IJ4.J851 63050 CorporalePlace, Suite 2 . Bend, Oregon 97701 . phone (541) 3824844 . fax (541) 382-4846