Loading...
HomeMy WebLinkAboutPermit Building 2008-5-28 (2) Status Issued CITY pF SPRINGFIELD Building/Combination Permit PERMIT NO: COM2008-00310 ISSUED: OS/28/2008 APPLIED: 03/04/2008 EXPIRES: 06/19/2009. VALUE: $ 1,904,658.00 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line SITE ADDRESS: 400 INTERNATIONAL WAY ASSESSOR'S PARCEL NO.: 1703154000500 SPRtNGFIETYPE OF WORK: Office TYPE OF USE: New Commercial PROJECT DESCRIPTION: Building Shen Only Owner: HAWES INVESTMENTS LLC Address: 2892 CRESCENT AVE EUGENE OR 97408 Phone Number: 541-335-5594 I CONTRACTOR INFORMATION I Contractor Type Arcbitect General Electrical Low Voltage Electrical Mechanical Plumbing Contractor ERIC HALL ARCHITECTS, INC. 1996 LLC BUILDERS ELECTRIC INC COMFORT FLOW COMFORT FLOW TWIN RIVERS PLUMBING INC License Expirat'ion Date 114258 4296 ....,460 460 17695 0513012011 1211012011 06/2712009 06/2712009 0311112009 Phone 541-688-5594 541-687-9445 541-485-0922 541-726-0100 541-726-0100 541-688-1444 # of Units: Primary Occupancy Group: S~condary Occupancy Group: Primary Construction Type Secondary Construction Type: # of Bedrooms: I, BU~~DING INFOR,MATION I , I}_~' .. p, ,.. 1. r. :,..... .~ 1~\" ~-;'- .....,...-."/.",..,~'O 1 . # of Stories: " "3' B ! Height of S,tructure' ,1 1 M i Type of Heat: , DB l... Water Type:. '", ,'-. :,lJY ca: ,-.,~ Range Type:ll i .'l'~: t' 31Ij;.....;~;.0Ite numb~rEnergy l'atb:V, L,Hi.y NCi:fic",[,on (Spriiikied'iB't1ildi6g:~'2344). Yes Lot Size:' Sq Ft 1st Floor: Sq Ft 2nd Floor: Sq Ft Basement: Sq Ft GaragelCarport Sq Ft Other: Occupant Load: 307,098 35,521 24,663 20,293 I DEVELOPMENT INFORMATION I REQUIRED PARKING Front yard Setback: Side 1 Setback: Side 2 Setback: Rearyard Setback: Solar Setbacks: Street Improvements: Storm Sewer Availahle: Special Instruction: ',". Overlaypjst: ,. # Street Trees Rqd: Paved Drive Rqd: % of Lot ,Coverage: NOTIC~ ~ rnl~ ...-~,-'- . AUTH'IPUBLlQIMeB.qJX';.lW"~~"E WO COM~ENC'-EUD UIVUtK THIS PERMIT IS ~walk Type: , OR IS ABANDONED ANY 180 DAY PERIOD. FOR DownspoutslDrains: Total: Handicapped: ,Compact: Notes: ,'.: Pa2e 1 of 6 Status 'Issued CITY OF SPRINGFIELD Building/Combination Permit PERMIT NO: COM2008-00310 ISSUED: OS/28/2008 APPLIED: 03/04/2008 EXPIRES: 06/19/2009 VALUE: $ 1,904,658.00 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line I Valua!ion Oescriotion I Description Tvpe of Construction Bid Amount Use Bid Amount $ PerSq Ft or multiplier $1.00 Square Footage or Bid Amount 1,904,658.00 Value $1,904,658,00 $1,904,658.00 Date Calculated 03/07/2008 Total Value of Project L.Fp~, P1itl I Fee Description Amount Paid Date Paid Receipt'Number Plan Review Comm/Ind/Public $4,605,08 3/4/08 1200800000000000199 + 10% Administrative Fee $1,513,24 5/28/08 2200800000000000770 + 12% State Surcharge $850,17 5/28/08 2200800000000000770 + 5% Techuology Fee $354.24 5/28/08 2200800000000000770 Building Permit $7,084.74 5/28/08 2200800000000000770 Fire SF Fee - Non-Residential $8,047,70 5/28/08 2200800000000000770 Plan Review Fire & Life Safety $2,833.90 5/28/08 2200800000000000770 SDC Sanitary/Storm Admin $679.88 5/28/08 2200800000000000770 Storm Drainage Impervious Area $13,597.57 5/28/08 2200800000000000770 + 10% Administrative Fee $5,00 6/13/08 2200800000000000898 + 12% State Surcharge $6,00 6/13/08 2200800000000000898 + 5% Techuology Fee $2.50 6/13/08 2200800000000000898 Low Voltage - Commercial Indns $50,00 6/13/08 2200800000000000898 + 10% Administrative Fee $194,70 6/23/08 1200800000000000679 FLS Safety Systems Review $1,947.00 6/23/08 1200800000000000679 + 10% Administrative Fee $155.40 8/4/08 1200800000000000839 FLS Safety Systems Review $1,554,00 8/4/08 " 1200800000000000839 + 100/0 Administrative Fee $21.00 8/21/08 2200800000000001271 + 12% State Surcharge $25.20 8/21/08 2200800000000001271 + 5% Technology Fee $10.50 8/21/08 2200800000000001271 Add, Alter, Extend Circ $50,00 8/21!08 2200800000000001271 Add, Alter, Extend Circ Ea Add $160.00 8/21/08 2200800000000001271 Temp Occupancy $1,048.00 12/19/08 2200800000000001762 Temp Occupancy $1,048.00 ' 1116/09 2200900000000000063 Total Amount Paid $45,843.82 Initial Review 03/05/2008 l Plan Reviews ~ 03/07/2008 APP LLH Unable to enter structural review due to tag placed on parcel by planning for annexation agreement. Addressing fee collected with foundation permit. Page 2 of 6 CITY OF SPRINGFIELD Building/Combination Permit Status Issued PERMIT NO: COM2008-00310 225 Fifth Street, Springfield, OR ISSUED: OS/28/2008 541-726-3753 Phone APPLIED: 03/04/2008 541.726-3676 Fax EXPIRES: 06/19/2009 541.726-3769 Inspection Line VALUE: $ 1,904;658.00 SUB Review 03/07/2008 03/21/2008 APP DH Pass energy code review. See attached documents. Planninl! Review 03/07/2008 03/24/2008 APP EMM Structural Review 03/12/2008 04/0112008 APP LLH Plans reviewed by Mick Nolte with the Building Department under contract with the City of Springfield, Fire Department Review 03/07/2008 04/10/2008 OK GRG See attached document for Fire Department Plans Review comments. Initial Review 04/10/2008 04/10/2008 10 LLH Deferred submittal required for class II hood and exhaust Initial Review 04/1112008 04/1112008 10 LLH Faxed special inspection form and deferred submittal form to Eric Hall, Initial Review 04/18/2008 04/18/2008 APP LLH Addendum to sbell currently under review. Puhlic Works Review 04/18/2008 04/18/2008 APP JHJ Attached revised SDC worksbeet. Plauninl! Review 04/18/2008 04/22/2008 APP EMM Addendum to shell currently under review. To be constructed per approved Final Site Plan DRC2007-00060, Structural Review 04/18/2008 04/25/2008 APP LLH Addendum to shen currently under review, Reviewed by Mick Nolte with the Building Department under contract with the City of Springfield Public Works Review 03/07/2008 05/0112008 APP JHJ Attached revised SDC Worksheet, (JHJ) Pal!e 3 of 6 CITY OJ:< ~rRIl'i{jJ:<lELD . Building/Combination Permit PERMIT NO: COM2008-00310 ISSUED: OS/28/2008 APPLIED: 03/04/2008 EXPIRES: 06/1912009 VALUE: $ 1,904,658.00 . , Status Iss u ed 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Iuspection Line Fire Department Review OS/25/2008 APP GRG OS/25/2008 , Fire Department Review 06120/2008 06/20/2008 APP GRG Fire Department Review 07/2512008 07/25/2008 OK GRG Plans Review: revised submittal of Hawes building project-building shen only (Package B), Job #COM2008-00310. Occupancy Classifications: A-2, A-3, B, M, Construction Type: It-B sprinklered, Square footages: 1st floor: 35,521 sq, ft.; 2nd floor: 24,663 sq. ft,; 3rd floor: 22,177 sq, ft.; Total: 78,174 sq, ft, Revised su~mittal changes do not affect original fire plans review comments dated 4/10/08. Refer to original submittal for lire plans review comments. See attached document for Fire Department Sprinkler Plans Review comments. Plans Review: Fire Alarm System for Hawes Building, Job #COM2008-00310, Designer: Steve Francalancia. Contractor: Om lid and Swinney. The proposed system is a GamewelllFire Control Instruments Model E3 Classic fire alarm control panel monitoring three supplemental notification strobe power supply panels, a network transponder and a remote annunciator. 12 notification appliance circuits, 6 amp module 'output circuits for the voice alarm system, w3;ter flow and tamper monitoring and smoke control monitoring through beam detection make up the system,. Plans appear to meet code requirements. To Request an inspection call the 24 hour recording at 726-3769. All inspections requested before 7:00 a.m. will be made the same working day, inspections requested after 7:00 a.m. will be made.the following work day. Paee 4 of6 CITY OF SPRINGFIELD Building/Combination Permit Status Issued PERMIT NO: COM2008-00310 ISSUED: OS/28/2008 APPLIED: 03/0412008 EXPIRES: 06/1912009 VALUE: $ 1,904,658.00 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line L-RronirprlJnsnections I Framing Inspection: Prior to cover and after all rough in inspections have been approved, Roof Sheathing Firewan: Located and constructed according to plans, Masonry: Bolts Instaned in Concrete: To be done by a State Certified Special Inspector. Provide inspection test reports to City Building Inspector, Structnral Concrete: In excess of 2500 psi. To be done 'during construction by aState Certified Inspector. Provide results to City Buiding Inspector Hold Downs Installed: Special Inspection performed prior to placement of concrete. Provide report to City Building Inspector. Epoxy Anchors: To be done by Certified Spcial Inspector, Provide Inspection results to City Building Inspector. High Strength Bolting: To be done during constructiou by a State Certified Special Inspector, Provide inspection res nits to City Building Inspector: Special Inspection: Weld Inspection: To be done during construction by a State Certified Special Inspector with approval from the City of Springfield. Copies of inspection results shall be provided to the City of Springfield. Special Inspection: High Strength Bolting Inspection: To be done during construction by a State Certified Special Inspector with approval from the City of Springfield. Copies of inspection results shall be provided to the City of Springfield, Special Inspection: Moment Resisting Steel Frames Inspection: To be done during construction by a State Certified Special Inspector with approval from the City of Springfield, Copies of inspection results shan be provided to the City of Springfield. Special Inspection: Masonry, Mortar, Grout, and Reinforcing Steel Certificates Inspection: To be doue during construction by aState Certified Special Inspector with approval from the City of Springfield. Copies of inspection results shan be provided to the City of Springfield, Final Building: After an required inspections have been requested and approved and the bnilding is complete, SUB Insulation Vapor Barrier: To be caned for at the same time as the SUB framing inspection, . . SUB Final: After all required energy inspections have been requested and approved, SUB Mechanical: Fonowing City Rough Mechanical inspection' approval and prior to any cover. SUB Ceiling Grid: Interior Lighting SUB Exterior Lighting Low Voltage: Prior to cover, Rough Electric: Prior to Cover Final Electric: When all electrical work is complete. Pal!e 5 of6 Status Issued CITY Vi' ~rRINGFIELD Building/Combination Permit PERMIT NO: COM2008-00310 ISSUED: OS/28/2008 APPLIED: 03/04/2008 EXPIRES: 06/19/2009 VALUE: $ 1,904,658.00 225 Fifth Street, Springfield, OR 541-726'3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line By signature, I state and agree, that I have carefuny examined the completed application and do hereby certify that all information hereon is true and correct, and I further certify that any and an work performed shall be done in accordance with the Ordinances of the City of Springfield and the Laws of the, State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made of any structure without permission of the Community Services Division, Building Safety, I further certify that only contractors and employees who are in compliance with ORS 701.005 will be used on this project, I further agree to ensure that all required inspections are requested at the proper time, that each address is readable from the street, that the permit card is located at the front of the property, and the approved set of plans will remain on the site at an times during construction. ~.._.~., .' ~t-.._,_.., /-/(#-09 Owner or co~~r~Signature Date Pa~e 6 of6 225 Fifth Street S~ringrield, Oregon 97477 541-726~3759 Phone City of Springfield Official Receipt Development Services Department Public Works Department RECEIPT #: 2200900000000000063 Date: 01116/2009 1O:36:23AM Payments: Type of Payment Check .Paid By. CHAMBERS CONSTRUCTION Item Total: Check Number Authorization Received By Batch Number Number How Received Amount Due 1,048.00 $1,048,00 Job/Journal Number COM2008-00310 Description Temp Occupancy Amount Paid cjc 70838 In Person Payment Total: $1,048.00 $1,048,00 cRecei!ltl Page I of I 1/16/2009.