City of Springfield
Building Permit & Inspection Summary
10/23/2007
. 8:56:05AM
Job #:
COM2007-01346
225 Fifth Street
541-726-3753 Phone
541-726-3676 Fax
Job Address: 6883 FORSYTHIA ST
Scope of Work: Foundation'
Description of Work: Foundation repair
Springfield
Project Status: Issued
. -.>-.
Name
CON SOLID GROUND
OWN TOWERY JEFFREY R & DORIS G
Owner & Contractor(s)
Address
880 S. 45TH STREET
6883 FORSYTHIA ST
City. State. ZiD
SPR[NGFIELDOR 97478
SPRINGFIELD OR 97478
Phone
744-8998
541-726-3700
Valuation of Proiect
OccuDancv
Construction TVDe
Cost Per So Ft So Ft!\
Date
Valuation Calculated Staff
DescriDtion
Amount Paid
Fees Paid
Date Paid
ReceiDt #
Foundation Permit
+ 5% Technology Fee
+ 8% State Surcharge
+ 100/: Administrative Fee
Tota[ Amount Paid
$75.74
$3.79
$6.06
$7.57
$93.16
09/0412007
09104/2007
09/0412007
09/04/2007
1200700000000001154
1200700000000001[54
. 1200700000000001154
1200700000000001154
Plans Reviewed
..-.,,;....
DeDartment
Received Due Date ComD1eted Result Reviewer Comments
,
Structural Revi~~
-'
0910412007
09/1412007 09/04/2007 APP
DLM
InsDections Conducted
InsDections Comments Date Result InsDector
Footing
Footing
Footing "- contractor has installed grade 10/1612007 10 RWC
beams without inspection
Soils - Compaction 10/1612007 RWC
I of 1
b"
.a
K & A Engineering, Ine,
P,O, Box 23624, Eugene, OR 97402.
521 Market SI., Suite B, Eugene, OR 97402
(541) 684-9399 Voice
(541) 684-9358 FAX
enginl?l?ring
October 16, 2007
Mr, Jeff Towery
6883 Forsythia Street
Springfield, OR 97478
Project: 223.06
Subject: Special inspection - foundation repair
Springfield permit no. COM2007 -01346
6883 Forsythia SI., Springfield, OR
/
PURPOSE AND SCOPE
As requested, K & A Engineering, Inc, has made several inspections of the subject foundation repair project
currently underway, The purpose of our inspections were to review work completed, provide recommendations
to the contractor for required changes or modifications, and to ensure that the work completed met the
specifications and intent of the repair plan,
This project includes repair of the foundation of the west side of the garage only and installation of drainage
along the west side of the residence, This repair plan does not. include underpinning or repair of other parts of
the foundation,
INSPECTIONS
Subsurface Drainage System
We inspected the new subsurface drain system as it was constructed. This system was installed according to
our specifications and recommendations, The trench extended below the ground surface to native un'disturbed
sandstone. The side of the trench facing the foundation extended through approximately 2-feet of saturated
organic clays located on the surface of native sandstone. The trench depth ranged from 4 to over 6-feet in
depth, A significant amoun(of water was drained from the organic layer during construction,
The perforated trench drain pipe was connected to a solid drain pipe which was routed to the curb weep hole on
the south side of the street at the west side of the driveway. .
,
. West Garage Foundation
Shoring and Removal of Existing Footing and Slab
The west garage wall and roof structure was shored and separated from the foundation and approximately 10,6-
feet of the west footing and stem wall was removed, extending from the west side of the portal frame at the .
garage opening to the man door, See the attached As-Built Repair Plan. Additionally, a portion of the existing
interior concrete slab-on-grade was removed,
K & A Engineering, Inc,
After removal of the slab and existing foundation, the west portal frame footing and wall were repositioned to a
plumb condition,
Helical Pier Installation
Three helical piers were insfalled at the locations shown on the attached As-Built Repair Pian, Two of the piers
support a preconstruction "T" bracket to be embedded into the new concrete grade beam, The third pier,
located at the remaining eXisting portal frame foundation, supports a conventional steei bracket. Due to the
iocation of iarge boulders in the bedrock, the pier locations and helix configurations were modified from the
original repair plan. We evaluated the static load capacity of the piers, as installed, and have determined that the
available load capaCity exceeds the required capacity, See Table 1 for a summary of the pier installation,
Concrete Grade Beam
A new concrete grade beam was constructed with the dimensions and reinforcing meeting our original
specifications: This grade beam was attached 'to the remaining existing portal frame foundation at the northwest
. corner. The grade beam was attached to the eXisting foundation using 4 - 5/8" diameter grade 60 steel dowels
that extended a minimum of 7 -inches into the existing concrete. The grade beam was reinforced according to
the project design and specifications.
Cripple Wall
The existing framed cripple wall supporting the floor of the residence along the south side of the garage was
repaired according to our plans. .
SUMMARY AND RECOMMDATIONS
This report documents our inspections made of construction for the subject project. Work compieted as of the
date of this report includes construction of an exterior perimeter subsurface drain system, installation of three
(3) new helical piers, cripple wall repair, and a new concrete grade beam, The construction of these elements
Project: 223,06
Client: Towery
6883 Forsythia St., Springfield, OR
Page 2 of 3
October 16, 2007
, ,
K & A Engineering, Inc,
was made in accordance with our design or, in the case of changes, was made with our approval and according
to modified'design recommendations, .
We recommend,acceptance of these elements, as constructed, by the local building official.
The project is not yet completed: and we anticipate making at least one more inspection report based on
additional site inspections.
Thank you for the opportunity to be of service. Please call me if you have any questions, .
Sincerely,
Project: 223,06
CHen!: Towery
6883 Forsythia St., Springfieid, OR
Page 3 of 3
October 16, 2007
, '
','
.
ka
engineering
geotechnical/civil
engineering
Eugene, OR 97408
541 684 9399 541 684 9358 fax
Project: 6883 Forsvthia SI.
Client: Towmv
Job No: 223,06 Date: 9-28-07
Sheet: 1 of 1
r
'\
_ __ ~ _ _ _ _ frr4~t _ __ __ _ __ _,
i"--------J L_________, 1
I I I
I I I
I I I
I I I
I I I
I I
i I I
II I
I I
I I I
I I I NEW eONC, SLAB
I I V SA WCU. T EXIST. S'LAB
19.3' REPAIR CRIPPLE WALL SUPPORTING FLOOR
I REPLACE STUOS@16'O,C, -I-
APPLY 1/2" COX SHEARTHING NEW CONe.
INAILEO USING 8d @ 6" 0,0, I. GRADE BEAM WEST
I , GARAGE WALL
I r :- ~ ":L .:-, -:: ::- ,-:.. ;:::-'-l.. ,~~ ~~,7!- I
I I I 1------ l I
I I ,I I _I
I L----~i I I I
l'....-----ill I I I
I L':"__";] I I S8
L'----lIILJ I : :;
l'...._, 1 ~
:: .~~~.:.
:1: ~ ,'~ '
:-t______;\ ~~-1
LL____~~____~~ T
e
."
""
w
~
w
co
""
'"
'"
(0 c..;;i
c:i a
<0 '"
;s: <ci
w
z
o
N
'-
<ci
SAWCUT EXIST FOUNDATION
OOWEL GR, BEAM TO EXIST. CONC,
USING 2 ' #4
EPOXY fNTO EXIST. CONC,
(;\ AS-BUILT REPAIR PLAN
o 1"=8'
& STEEL HELICAL PIER WITH PIER eRACKET AT EXISTING FOOTING,
<8 STEEL HELICAL PIER WITH "T" FITTING SUPPORTING NEW CONCRETE GRAOE BEAM
, '
"
Roof Beamf 2003 International Residential Code (01 NDS) 1 Ver: 7.01.10
By: Donald Moore. City of Springfield on: 10-23-2007 : 2:46:36 PM
Proiect: Petrushkin 07-1052 - Location: Garage door header
Summary: .
5,125 IN x 10.51N x 14.5 FT /24F-V4 - Visually Graded Western Species - Dry Use
Section Adequate By: 18,8% Controlling Factor: Section Modulus / Depth Required 9,75 In
Deflections:
Dead Load:
Live Load:
Total Load:
Reactions (Each End):
Live Load:
Dead Load:
Total Load:
Bearinq Lenqth Required (Beam only, support capacity not checked):
Camber Reqd,:
Beam Data:
Span: .
Maximum Un braced Span:
Pitch Of Roof: _
Live Load Deliect. Criteria:
Total Load Deflect. Criteria:
Camber Adjustment Factor:
Roof Loadinq: .
Roof Live Load-Side One:
Roof Dead Load-Side One::
Tributary Width-Side One:
Roof Live Load-Side Two:
Roof Dead Load-Side Two:
Tributary Width-Side Two:
Roof Duration Factor:
Beam Self Weiqht:
Slope/Pitch Adiusted Lenqths'and Loads:
Adiusted Beam Lenqth:
Beam Uniform Live Load:
Beam Uniform Dead Load:
Total Uniform Load:
Properties For: 24F-V4- Visually Graded Western Species
Bendinq Stress:
Shear Stress:
Modulus of Elasticity:
Stress Perpendicular to Grain:
Bendinq Stress of Compo Face in Tension:
Adjusted Properties
Fb' (Tension):
Adjustment Factors: Cd=1.15 CI=1.00
DLD=
LLD=
TLD=
LL-Rxn=
DL-Rxn=
TL-Rxn=
BL=
C=
L=
Lu=
RP='
U
U
CAF=
LL1=
. DL1=
TW1=
LL2=
DL2=
TW2='
Cd=
BSW=
Ladi=
wL=
wD adi=
-wT=
Fb=
Fv=
E=
Fc perp=
Fb_cpr=
Fb'=
Fv':
Fv'=
Adiustment Factors: Cd=1.15
Design Requirements:
Controllinq Moment:
7,25 ft from left support
Critical moment created by combining all dead and live loads.
Controllinq Shear:
At a distance d from support.
Critical shear created by combining all dead and live loads,
Comparisons With Required Sections: .
. Section Modulus (Moment):
Area (Shear):
Moment of Inertia (Deflection):
M=
V=
Sreq=
S=
Areq=
A=
Ireq=
1=
0.31 IN
0.47 IN = U372
0.77 IN = U225
3036 LB
1982 LB
5018 LB
1.51 IN
0.46 IN
14.5 FT
2.0 FT
3.5 : 12
240
180
1.5 X DLD
25.0 PSF
15.0 PSF
16,75 FT
25.0 PSF
15,0 PSF
0.0 FT
1.15
12 PLF
14,5 FT
419 PLF
273 PLF
692 PLF
2400 PSI
240 PSi
1800000 PSI
650 PSI
1850 PSI
2753 PSI
276 PSI
18190 FT-LB
4416 LB
(79.29 IN3
94.17 IN3
24.00 IN2
53.81 IN2
395.57 IN4
494.40 IN4