Loading...
HomeMy WebLinkAboutPermit Miscellaneous 2007-5-4 -.. CertainTeed II Builders Statement InsulSafe<SJ4 _ \ Premium Blowing Wool jJ/!/)';)) !-lA"}.... Ji Ami? S Homeow~r Name / Jobslte Name Jfr- d /~i.f ~ddresL-- I. ' W{:{ Ill.. IV Installer/Contractor (Iign) 71'~tf .,10f7/1'.I MU !.t..,../t>1. c: Company Name q 1'-oate Date &t-. Builder (sign) Company Name Inspected By (sign it required) NO. OF BAGS PER MAXfMUM MINIMUM INITIAL INSTALLED R.VALUE 1,000 SQ. FT. NET AREA NET COVERAGE WEfGHT THfCKNESS To obtain a Conlenlso/bag Weight per sq. ft. of Should not be Thermal Resistance No.afBags should not cover installed insulation should lesslhan: (Ajar: more lhan: {sq. fl.) nol be lesslhan: (lbsJsq.ft.) (in.) 60 36.5 27 0.986 22.00 49 29.6 34 0.800 I 18.50 44 26.4 3B 0.712 16.75 38 22.8 44 0.615 14.75 3D 18.0 56 0.485 12.00 26 15.5 65 0.418 ,10.50 22 13.1 77 0.353 9,00 19 11.1 90 0.301 7.75 13 7.7 129 0,209 5.50 11 6.6 151 0.179 4.75 R.VALUE THICKNESS AREA (Sa. FT.) rnsu'71 BAGS USEO 38 )tf3/y tso /7 CEILINGS 6()D :56 WALLS 621 II t> 6 FLOORS ~<;; I;). SO L{)~ .5 ,'1-07 Date MINIMUM SETTLED THICKNESS Should not be less than: (in.) 22.00 18.50 16.75 14.75 12.00 10.50 9.00 7.75 5,50 4.75 BATTSlROLLS (") / t/ ~ V THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION In accordance with the chart above, you must install the minimum number of bags per 1,000 sq. ft, of net area for each R-Value listed. . The maximum net coverage must not exceed that specified for each R-Value. The installed insulation must be at or above the specified minimum thickness for each R-Value. Failure to install the required minimum weight per sq. ft. of insulation at or above the minimum thickness will result in reduced R-Value. . This product should not be mixed with other blown insulations or the thermal claims will become invalid. . Initial installed thickness testing per ASTM C 1374 using Unisul VoluMatic III; 3rd gear; 16.inch gate opening; 150-ft. x 3-1/2 inch-diameter internally corrugated blowing hose. R-Values are determined in accordance with ASTM C 687 and C 518, Complies with ASTM C 764 as Type 1 insulation. "R" means resistance to heat flow. The higher the R-Value, the greater the insulating power, To get the desired R-Value, it is essential that the insulation is installed properly. DANGER: RECESSED LIGHT FfXTURE5- TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WfTHIN 3" OF SUCH DEVfCES, DOES NOT APPLY TO TYPE IC LIGHT FIXTURES ORTO FLUORESCENT FIXTURES WITH THERMALLY PROTECTED BALLASTS, 30-24-233 InsuISa!e@4 Builders Statement A Sainl-Gobain Company @2005 CertainTeed Corporation 11/05 Manufacturer Insulation Fact Sheet This is CertainTeed Corporation I nsu ISafe@ 4 Premium Blowing Wool CertainTeed Corporation P.O. Box 860 Valley Forge, PA 19482 '1/ ) 0,1.0 ~- THERMAL PERFORMANCE-HORIZONTAL OPEN BLOW . .' The following thermal performances. are achieved at weights and coverages specified when insulation is installed with pneumatic equipment in a h~~:~o.ntal open blow application: "",--,'.----- NO. OF BAGs PER MAXIMUM MINIMUM INITIAL INSTALLED MINIMUM SETTLED R-VAlUE 1,000 SQ~FT:NET AREA NET COVERAGE WEIGHT THICKNESS THICKNESS To oblain a :..' Contents of bag Weighl per sq. ft. of Should not be Should not be Thermal Resistance .~~o.~,.aegs should nol cover installed insulation should less than: less than: (R)of: more than: (sq. ft.) not be less than: (lbsJsq, ft.) (in.) (in.) 60 36.5 27 0,ge6 22.00 22.00 49 29.6 34 0.800 18,50 18.50 44 26.4 38 0.712 le,75 16.75 38 22.8 44 0.615 14,75 14.75 30 .:;,. 18.0 56 0.485 12.00 12.00 26. 15.5 e5 0.418 10.50 10.50 22 13,1 77 0,353 9,00 9.00 :'"19 11.1 90 0.301 7,75 7.75 - 13 7.7 129 0.209 5.50 5.50 - .'1 . 11 6,6 151 0,179 4.75 4,75 R-v~lues are determined in accordance with ASTM C 687 and C 518. Complies with ASTM C 764 as Type 1 insulation. THERMAL PERFORMANCE-SIDEWALL RETROFIT APPLICATION When installed with pneumatic equipment in sidewalls, the following thermal performances are achieved at the thicknesses, weights and coverages specified. Based on a design density of 1.6 pcf/25.6 Kg/m3 ----- NO. OF BAGS PER MAXIMUM MINIMUM INITIAL INSTALLED MINIMUM SETILED R-VALUE 1,000 sa. FT. NET AREA NET COVERAGE WEIGHT THICKNESS THICKNESS To obtain a Contents of bag Weight per sq. fl. of Should not be Should not be Thermal Resistance No. 01 Bags should not cover installed insulation should less than: less than: (A)ofc more than: (sq. fl.) not be less than: (Ibs.lsq. fl.) (in.) (in.) 29 35.8 28 0,967 7.25 7.25 22 27.2 37 0.733 S.50 5.50 16 19.8 51 0.533 4,00 4.00 15 17.9 56 0.483 3.625 3,625 14 17,3 58 0.467 3.50 3.50 BEAnTHI>; RFFORFYOIJ RIJY What you should know about R-Values: The chart shows the R-Value of this insulation. R means resistance to heat flow. The higher the R-Value, the greater the insulating power. Compare insulation R-Values before you buy, There are other factors to consider. The amount of insulation you need depends mainly on the climate you live in, Also, your fuel savings from insulation will depend upon the climate, the type and size of your house, the amount of insulation already in your house, and your fuel use patterns and family size, If you buy too much insulation, it will cost you more than what you'll save on fuel. To get the marked R-Value, it is essential that this insulation be installed properly,