NO. OF BAGS PER MAXfMUM MINIMUM INITIAL INSTALLED
R.VALUE 1,000 SQ. FT. NET AREA NET COVERAGE WEfGHT THfCKNESS
To obtain a Conlenlso/bag Weight per sq. ft. of Should not be
Thermal Resistance No.afBags should not cover installed insulation should lesslhan:
(Ajar: more lhan: {sq. fl.) nol be lesslhan: (lbsJsq.ft.) (in.)
60 36.5 27 0.986 22.00
49 29.6 34 0.800 I 18.50
44 26.4 3B 0.712 16.75
38 22.8 44 0.615 14.75
3D 18.0 56 0.485 12.00
26 15.5 65 0.418 ,10.50
22 13.1 77 0.353 9,00
19 11.1 90 0.301 7.75
13 7.7 129 0,209 5.50
11 6.6 151 0.179 4.75
R.VALUE THICKNESS AREA (Sa. FT.) rnsu'71 BAGS USEO
38 )tf3/y tso /7
CEILINGS 6()D
:56
WALLS 621 II t> 6
FLOORS
~<;; I;). SO
L{)~
.5 ,'1-07
Date
MINIMUM SETTLED
THICKNESS
Should not be
less than:
(in.)
22.00
18.50
16.75
14.75
12.00
10.50
9.00
7.75
5,50
4.75
BATTSlROLLS (")
/
t/
~
V
THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION
In accordance with the chart above, you must install the minimum number of bags per 1,000 sq. ft, of net area for each
R-Value listed.
. The maximum net coverage must not exceed that specified for each R-Value.
The installed insulation must be at or above the specified minimum thickness for each R-Value.
Failure to install the required minimum weight per sq. ft. of insulation at or above the minimum thickness will result in
reduced R-Value.
. This product should not be mixed with other blown insulations or the thermal claims will become invalid.
. Initial installed thickness testing per ASTM C 1374 using Unisul VoluMatic III; 3rd gear; 16.inch gate opening;
150-ft. x 3-1/2 inch-diameter internally corrugated blowing hose.
R-Values are determined in accordance with ASTM C 687 and C 518, Complies with ASTM C 764 as Type 1 insulation.
"R" means resistance to heat flow. The higher the R-Value, the greater the insulating power, To get the desired
R-Value, it is essential that the insulation is installed properly.
DANGER: RECESSED LIGHT FfXTURE5- TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WfTHIN 3" OF SUCH
DEVfCES, DOES NOT APPLY TO TYPE IC LIGHT FIXTURES ORTO FLUORESCENT FIXTURES WITH THERMALLY
PROTECTED BALLASTS,
30-24-233 InsuISa!e@4 Builders Statement
A Sainl-Gobain Company
@2005 CertainTeed Corporation 11/05
Manufacturer Insulation Fact Sheet
This is CertainTeed Corporation I nsu ISafe@ 4
Premium Blowing Wool
CertainTeed Corporation
P.O. Box 860
Valley Forge, PA 19482
'1/
)
0,1.0
~-
THERMAL PERFORMANCE-HORIZONTAL OPEN BLOW
. .'
The following thermal performances. are achieved at weights and coverages specified when insulation is installed with
pneumatic equipment in a h~~:~o.ntal open blow application:
"",--,'.-----
NO. OF BAGs PER MAXIMUM MINIMUM INITIAL INSTALLED MINIMUM SETTLED
R-VAlUE 1,000 SQ~FT:NET AREA NET COVERAGE WEIGHT THICKNESS THICKNESS
To oblain a :..' Contents of bag Weighl per sq. ft. of Should not be Should not be
Thermal Resistance .~~o.~,.aegs should nol cover installed insulation should less than: less than:
(R)of: more than: (sq. ft.) not be less than: (lbsJsq, ft.) (in.) (in.)
60 36.5 27 0,ge6 22.00 22.00
49 29.6 34 0.800 18,50 18.50
44 26.4 38 0.712 le,75 16.75
38 22.8 44 0.615 14,75 14.75
30 .:;,. 18.0 56 0.485 12.00 12.00
26. 15.5 e5 0.418 10.50 10.50
22 13,1 77 0,353 9,00 9.00
:'"19 11.1 90 0.301 7,75 7.75
- 13 7.7 129 0.209 5.50 5.50
- .'1
. 11 6,6 151 0,179 4.75 4,75
R-v~lues are determined in accordance with ASTM C 687 and C 518. Complies with ASTM C 764 as Type 1 insulation.
THERMAL PERFORMANCE-SIDEWALL RETROFIT APPLICATION
When installed with pneumatic equipment in sidewalls, the following thermal performances are achieved at the
thicknesses, weights and coverages specified. Based on a design density of 1.6 pcf/25.6 Kg/m3
-----
NO. OF BAGS PER MAXIMUM MINIMUM INITIAL INSTALLED MINIMUM SETILED
R-VALUE 1,000 sa. FT. NET AREA NET COVERAGE WEIGHT THICKNESS THICKNESS
To obtain a Contents of bag Weight per sq. fl. of Should not be Should not be
Thermal Resistance No. 01 Bags should not cover installed insulation should less than: less than:
(A)ofc more than: (sq. fl.) not be less than: (Ibs.lsq. fl.) (in.) (in.)
29 35.8 28 0,967 7.25 7.25
22 27.2 37 0.733 S.50 5.50
16 19.8 51 0.533 4,00 4.00
15 17.9 56 0.483 3.625 3,625
14 17,3 58 0.467 3.50 3.50
BEAnTHI>; RFFORFYOIJ RIJY
What you should know about R-Values:
The chart shows the R-Value of this insulation. R means resistance to heat flow. The higher the R-Value,
the greater the insulating power. Compare insulation R-Values before you buy,
There are other factors to consider. The amount of insulation you need depends mainly on the climate
you live in, Also, your fuel savings from insulation will depend upon the climate, the type and size of your
house, the amount of insulation already in your house, and your fuel use patterns and family size, If you
buy too much insulation, it will cost you more than what you'll save on fuel.
To get the marked R-Value, it is essential that this insulation be installed properly,