Geotedmical & Construction Services
Daily Field Report
Client: Mr. Bret Fox Project: First Tech Credit Union Date: 06-05-07
Skyview LLC 1810 Pioneer Parkway W Project No,: 2077077
515 W. Pickett Circle Springfield, Oregon Report No,: E16469
SUite 400 Inspector: A. Fenstermacher
Salt Lake City, UT 84115 10 No.: 5258882-49
Inspection of: Reinforcing Steel Weather: Showers Continuous Inspection: 0
Contractor: Hyland Construction BP No,: COM2007 -00369. Periodic Inspection: 0
Performed preliminary inspection on the reinforcing steel for perimeter continuous and
pad footings and interior pad footings. Reinforcing steel was checked for size, grade,
laps, quantities, locations. ties, clearances and supports. At the time of inspection
approximately 25% of the anchor bolts and hold-downs were in-place. A final
inspection will be performed prior to concrete placement.
Dave Shaw (Hyland) was asked to notify our office when additional services are
needed.
To the best of our knowledge, the work inspected was in accordance with plans dated
02-09-07, revision dated 04-18-07, addendum dated 05-08-07 and applicable
workmanship provisions of the I.B.C., except if noted above.
Reviewed By:
~~;:~er
Technical Manager
c: Hyland Construction
City of Springfield
Affolter, West & Jones
MLM:jm
This report and/or enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific
process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part
thereof be disclosed without FEI Testing & Inspection, Inc.'s written authorization.
7'3) r-NV ComelAvenue' ColvaJlis, Oregon 97330. phone(541) 757-4698, fax (541) 757-2991
. 29540 B Airport Road . Eugene. Oregon 97402 . pha:e (541) 684-J849 ' fax (541) 684-0851
~tr~~
':'7 ~l
Page 1 of 1 ,
(I~' Ilmt:th\.' :f~'1lI11 till!
Geotechnical & Construction Servioes
Daily Field Report
Client: Mi. .Bret Fox Project: First Tech Credit Union Date: 06-06-07
Skyview LLC 1810 Pioneer Parkway W Project No,; 2077077
515 W. Pickett Circle' Springfield, Oregon . Report No,: E-16480
Suite 400 Inspector: R. Marjama
Salt Lake City, UT 84115 10 No,: 5235029-49
ICC
InspeCtion of: Reinforced Concrete Weather: Overcast Continuous Inspection: D
Contractor: John Hyland Construction BPNo.: COM2007"00369 Periodic Inspection: 0
Performed final inspection on the reinforcing steel for perimeter continuous footings,
. five (5) interior column spread footings and two (2) exterior spread footings for canopy
columns. Reinforcing steel was checked for grade, size, lap, placement and clearance.
Reinforcing steel was secured with tie-wire and supported above grade.
Observed the placement of 30.0 cuJyds, of Knife River 3000 psi concrete (Mix 30-1N)
in areas listed above. Concrete was' placed by pump and was mechanically
consolidated, Cast one (1) set of four (4) 6" x 12" concr~te test cylinders, Dave Shaw
(Joh'n Hyland Construction) was notified of on-site test results: slump 4 1/2"; concrete
temperature 68F; air temperature 58F.
Mr. Shawwas asked to notify our office when additional services are needed,
To the best of our knowledge, the work inspected was in accordance with plans dated
02-09-07 and applicable workmanship provisions of the I.B.C., except if noted above.
Reviewed By:
fh.-t.~ .
Michael L. Meyer
Technical Manager
,c: John Hyland Construction - (e-mail)
Affolter, West & Jones - (e-mail)
City of Springfield
MLM:jw
This report and/or enclosed test data is.the confidential property of the clientto" whom it is addressed and pertains to the specific
process and/or material evaluated. As such. information contained herein shall not be reproduced in part or full and/or any part
the~eof be disclosed without FEI Testing & Inspection, Inc.'s written authorization.
750 NW Com~1 Avenue' Corvallis, OregOn 97330 . phore (541) 757-4698 . fax (541) 757-2991
29540 B )\jrport Road' Eugene. Olegon 97402 . phone (541) 684-J849: fax (541) 684-J851
A~rp. ~
~7tt ~
II~'I Ii' I tf:t1 ~I~'~: IlllliU
CLIENT
Cw~c";',rlical & Construction Servioes .
Compressive Strength of Concrete
. (ASTM C 39)
Mr. Bret Fox
Skyview LLC
515 West Pickett Circle
Suite 400
Salt Lake City, Utah 84115
DATE CAST
STRENGTH REQUIRED
STRENGTH PLACED
PRODUCT CODE
ADDITIVES
LOAD NO.
CONCRETE TEMP
AIR TEMP
POUR LOCATION
LOAD 2 SAMPLED
TEST
DATE
06-13-07
07-04-07
07-04-07
Hold
AGE
(DAYS)
7
28
28
REMARKS:
PROJECT
First Tech Credit Union
1810 Pioneer Parkway E
Springfield, Oregon
DATE
PROJECT NO.
REPORT NO.
06-.13-07
2077077
5175
B.P. NO.
COM2007 -00369
06-06-07
3000 psi
3000 psi
2430N15200
CAST BY
06-07-07
DATE RECEIVED
SPECIMEN SIZE
SUPPLIER
.MAX SIZE AGG,
AIR CONTENT
2 TICKET NO, 2951710 SLUMP 41/2"
680 F YARDAGE . 10.75 OF 30.00 TIME 8:35 AM
580 F WEATHER Overcast SPECIMEN STORAGE ASTM C31
Perimeter continuQus footings, 5 interior column spread footings, 2 exterior column spread footings fqr
Canopy,
East side continuous footing.
R Marjama
6" x 12"
SACKS
CEMENT
MBI
3/4"
AREA
(IN.')
27.99
AVERAGE
STRENGTH
(PSI)
TYPE OF
FRACTURE"
D
WEfGHT
(LBS)
28.3
TOTAL
LOAD (LBS)
76000
COMPRESSIVE
STRENGTH (PSI)
2720
TIME OF
TEST
8:30 AM
.. A - Cone B - Cone/Split C - Cone Shear 0 - Shear E - Columnar
Dave (Hyland Construction) was advised of on-site test results.
Reviewed By:
A.;(.~
Michael L.~ Meyrf!
T echnicaJ Manager
c: John Hyland Construction - (e-mail)
Affolter, West & Jones - (e-mail)
Knife River
City of Springfield
MLM:jm
RECEIVED
JUN 1 8 1007
,
This report and/or enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific
process and/or material evaluated. As such, jnformation contained herein shall not be reproduced in part or full and/or ally part
thereof be disclosed without" FE! Testing '& Inspection, Inc.'s written authorization.
700 tfN OimellAvenue' Cavalis, Q-egon 97330, phone (541) 757-4698 . fax (541) 757-2991
29540 B Airport Road . Eugene, Q-egon 97402, phone (541)684-J849 . fax (541)684-3851