Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 2007-5-9 ----..- '... ._:~--- l"'~;l Information ,.,~. .To Build On' Engineering . Consulting. Testing L rc}uP-1J DAILY FIELD REPORT Date Pertormed: Client: May 9, 2007 Mr. Eric Patterson Lith ia Toyota 360 East Jackson Street Medford, Oregon 97501 . Report Number: 722-60359-67 Lithia Toyota - Quick Lube 863 Main Street Springfield, Oregon Project Name: Project Location: B,P, No,: Type of Inspection: ,COM 06-0868 Welding Inspection ,Weather: Inside/Overcast Field Observations and Comments Performed periodic visual inspection of the following items: Coiumn and bucket paddles single pass fiilet welds PC# (1) 10A, (1) 11A, (1') 12A, (1) 13A, (1) 14A, (4) 15A and (1)16A. Weldments were inspected for size, length, profile and locations. To the best of our knowledge, the work inspected is in conformance with approved drawings, specifications and applicable D1.1 (static) codes, Fabricator was asked to notify our office when additional services are needed.. 'Inspector: David Smith, Certification# 0877340-B5 If you have any questions ~egarding this report, please feel free to contact us at 541-746-9649. Respectfully Submitted, Professional Service 'ndustries, 'nc, ~ard~ Department Manager. c: City of Springfield 'John Hyland Construction Doug 'Snider Architect THIS REPORT IS PROVIDED FOR THE.INFORMA TION OF THE CLlE,,!T ONL Y. THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD . PARTY, BY ANY MEANS, EXCEPT IN FULL WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES, IS PROHIBITED Street. Springfield.. OR 97477. Phone 541/746-9649. Fax 541/746-7163 l ~~;lInfonnation ,.,~. .To Build On Engineering . Consulting . Testing DAILY FIELD REPORT Date Performed: June 14, 2007 Mr. Eric Patterson Lithia Toyota 360 East Jackson Street Medford, Oregon 97501 Report Number: 722-60359-71 Client: Project Name: Lithia Toyota 863 Main Street Springfield, Oregon Project Location: B,P, No.: Type of Inspection: COM 06-0868 Reinforcing Steel Weather: Clear Field Observations and Comments 'Performed continuous' inspection during the installation of #5 epoxied rebar dowels in ihe following locations: New concrete slab to existing concrete footing at the southeast quarter of service reception 101 (8 total), Prior to installation the predrilled holes were cleaned using a nylon brush and compressed air. Verified minimum embedment depth of 8 inches, The above listed epoxy anchors were installed USin9 Hilti Hit Hy150 epoxy with ICC#5193. The epoxy anchors were installed in accordance with latest revisions dated May 31, 2007 detail 2/SLI. Contractor was asked to notify our office when additional services are needed, To the best of our knowledge, the work inspected above was in accordance with the building department approved design drawings, revisions, specifications and applicable workmanship provisions ,of the International Buildinq Code, Inspector: Ray Aliperti, ICC# 1017075-88 If you have any questions regarding this report, please feel free to contact us at 541-746-9649. Respectfully Submitted, Professional Service 'ndustries, 'nc, pL~ Joseph Vardner, EIT Department Manager c: City of Springfield John Hyland Construction Doug Snider Architect THIS REPORT IS PROVIDED FOR THE INFORMATION OFTHE CLIENT ONL Y. THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TDA THIRD PARTY, BY ANY MEANS, EXCEPT IN FULL. WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES. IS PROHIBITED. Professional Service Industries, Inc.. 1Q40-A Shelley Slreet- Springfield, OR.97477. Phone 54~f746-9649. Fax 541n46.7163 ,- l"~;lInformation ,.,~. .To Build On Engineering . Consulting . Testing DAILY FIELD REPORT Date Performed: June 14, 2007 Report Number: 722-60359-70 Client: Mr. Eric Patterson Lith ia Toyota 360 East Jackson Street . Medford, Oregon 97501 Project Name: Lithia Toyota, 863 Main Street Springfield, Oregon Project Location: B,P. No,: Type of Inspection: COM 06-0868 Reinforcing Steel Weather:' Clear Field Observations and Comments Performed visual inspection of reinforcing steel at the following locations: Concrete slab on grade at the S9 quarter of reception 101 (details 8/54; 12/S4), Reinforcing steel was checked for grade, size, lap, placement, and clearances where applicable. Reinforcing steel was secured using tie wire and supported on concrete dobie blocks. Reinforcing steel was placed in accordance with approved design drawings and specifications. Note: Rebar will be placed on concrete dobies prior to placement of concrete, Contractor was asked to notify our office when additional services are needed. To the best of our knowledge, the work inspected above was in accordance with the building department aooroved desion drawina.s, sOf'cifications and aoolicable workmanship provisions of the International Buildino Code, Inspector: Ray Aliperti, ICC #101705-88 If you have any questions regarding this report, please feel free to contact us at 541-746,9649. Respectfully Submitted, Professional Service 'ndustries, Inc, 0/ t<:/ ~Ph Vardner, EIT Department Manager c: City of Springfield John Hyland Construction Doug Snider Architect THIS REPORT IS PROVIDED FOR THE INFORMA nON OF THE CLIENT ONL Y. THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TR/WSMITT AL TO A THIRD P'.eW..,RY AN>' M",NSnF.XCEPeTsIN FULJ-1/4/LrHOIJJ:hTH1 E WRiTTEN eERMISSION 8FRPROFESSIONAL SERVIC" INOUSTRIES, is PROHiBITEO, onar::ssrvn:;Sl au5m~ ,inC. U4U-A1:i1 eney titreet. tipnngtieJd, 97477. Phone 541n46-9649. Fax 5411746.7163 ~. L "'~;l Information ",~. .To Build On Engineering. Consulting . Testing DAILY FIELD REPORT Date Performed: June 5, 2007 Report Number: 722-60359-69 Client: Mr, Eric Patterson Lithia Toyota 360 East Jackson Street Medford, Oregon 97501 Project Name: Lithia Toyota 863 Main Street Springfield, Oregon Project Location: B,P, No.: Type of Inspection: COM 06-0868 Reinforcing Steel Weather: Showers Field Observations and Comments Performed visual inspection of reinforcing steel and anchor bolts at the following locations: F1 and' F3 footings at tciol room; 107 west wall and center of room; parts room 114 and parts room 114 to tool room 107, Reinforcing steel was checked for grade, size, lap, placement, and clearances where applicable, Contractor was asked to notify our office when additional services are needed. To the best of our knowledge, the work inspected above was in accordance with the building department approved design drawings, specifications and applicable workmanship provisions of the International Building Code. Inspector: David Smith, ,ICC #0877340-88, OBOA #442 .If you have any questions regarding this report, please feel free to contact us at 541-746-9649. Respectfully Submitted, Pro'essional Service 'ndustries, 'nc, -P< c~__ Joseph Vardner, EIT Department Manager c: City of Springfield John Hyland Construction Doug Snider Architect THIS REPORT /s PROVIDED FOR THE INFORMA nON OF THE CLIENT ONL Y. THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD . PARTY,'BY ANY MEANS. EXCEPT IN FULL. WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES, 1$ PROHIBITED. . - Professional Service Industries, Inc.. 1040-A Shelley Street. Springfield, OR 97477. Phone 5411746-9649. Fax 541f746-7163 1.-" -l~~;J Info11rUltion "''''.lTo Build On Engineering. Consulting. Testing DAILY FIELD REPORT Date Performed: June 5, 2007 Report Number: 722-60359-68 Client: Mr. Eric Patterson Lithia Toyota 360 East Jackson Street Medford, Oregon 97501 Project Name: Project Location: Lithia Toyota 863 Main Street Springfield, Oregon B,P. No.: Type of Inspection: COM 06-0868 Welding . Weather: Shop/Inside Field Observa~ions and Comments I Performed periodic visual inspection of the following items: Final weldments to columns MK #16A and 17 A and to brackets MK #18A(quantity 3). Also verified applicable welder certifications, WPS's and mill test reports are on file at fabricators office, Weldments were inspected. for size, length, profile and locations. To the best of our knowledge, the work inspected is in conformance with approved drawings, specifications and applicable AWS D1.1 codes. Fabricator was asked to notifv our office when' additional services are needed. Inspector: Chris Thomason, Certification 35069949-85 If you have any queslions regarding this report, please feel free to contact us at 541-746-9649. Respectfully Submitted, Professional Service 'ndustries, 'nc. ~.~ Joseph Vardner, EIT Department Manager' c: City of Springfield John Hyland Construction Doug Snider Architect THIS REPORT IS PROVIDED FOR THE INFORMATION OF THE CLIENT ONL Y. THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TOA THIRD PARTY, BY ANY MEANS, EXCEPT IN FULL, WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES, IS PROHIBITED. Professional Service In~ustries, Inc.. 1"040-A Shelley Stree.t. Springfield, OR 97477. Phone 541n46-9649. Fax 541n46-7163.