HomeMy WebLinkAboutPermit Field Test & Inspection Report 2007-5-17 ,I .',' q)riJ AI"~"" ~ '~rt~ 1I~'lh'll't;'h'.':l:'llIll_ G0.....~C....; II Ileal & Construction Services Page 1 of 1 Report of Inspection Services Weldinq/Hiqh-Strenqth Boltinq Client: Ms. Silva Sullivan Chambers Development Co. 2295 Coburg Road Suite 200 EUgene, Oregon 97401 Project: Sports Way Business Park-Ph, 2 3783 International Way Springfield, Oregon Date: Project No.: . Report No,: Inspector: ID No,: Inspection of: Fabricator or Erector: . Contractor: Welding West Side Iron Chambers Construction Co. Shop: 0 Weather: BP No,: 05-17-07 2077031 E-16292 C, Walpole 01040131 AWS CWI Field: iii Clear C-06;,o1357 Performed preliminary visual inspection durin9 work in-progress at the second fioor per erector's request. Welding was being performed by certified welders at brace frame and joist connections. Puddle welding was also being. performed by certified welders. Welding was not complete at several locations throughout the second floor connections. Erector and I reviewed all areas that need completion and would'require re- inspection for final acceptance. Contractor was asked to notify our office when additional services are needed, To the best of our knowledge, the work in-progress is in conformance with structural drawings and applicable AWS D1.1 and D1 ,3 codes, except if noted above. Reviewed By: d1L~ Structural Steel Supervisor c: Chambers Construction Co, - Brian Erickson (e-mail) Eric Hall Architects - Steven CholAnnette Rohde (e-mail) Endex Engineerin9 - (e-mail) City of Springfield DAW:jw RECEIVED MA~ 2 \) 1007 This report and/or enclosed test data is the confidential property of the clienllo whom it is addressed and pertains to the specific process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part thereof be disclosed without FEI Testing & Inspection, Inc's written authorization. . 750 NW Cornell Avenue' Corvallis, Oregon 97330 ' phone (541) 757-4698 . fax (541) 757-2991 29540 B'Airport Road' Eugene, Oregon 97402. phone (541) 684--3849, fax (541) 684--3851 63050 Corporate Place, Suite 2 . Bend, Oregon 97701 ' phone (541) 382-4844 . fax (541) 382-4846 I~rp . ~lttJ Page 1 of 1 Report of Inspection Services WeldinQ/HiQh-StrenQth BoltinQ 11:"lh'ltt:"IL'~'~:'llll;IiII.'lGl Geotechnical & Construction Services Client: Ms, Silva Sullivan Chambers Development Co, 2295 Coburg Road Suite 200 Eugene, Oregon 97401 Project: Sports Way Business Park-Ph, 2 3783 International Way Springfield, Oregon Inspection of: Fabricator or Erector: Contractor: Fabrication Welding Gibson Steel Chambers Construction Co. Date: Project No.: Report No,: Inspector: ID No.: Shop: Iii'! Weather: BPNo.: 05-17 -07 2077031 E-16293 L. Postier 06120541 AWS CWI Field: 0 Inside C-06-01357 Performed visual inspection on the following structural steel components: tube steel headers (16) H1, H2, (2) H3, (16) H4, H5 and (2) H6; stairs (2) S1 and (2) S2; columns (2) SC3, SC4, (2) SC5 and SC6 and landing beams (2) JB3 and (2) LB4. Completed welds were checked for size, length, profile and location. Fabricator was asked to notify our office when addition~1 services are needed. ' To the best of our knO~ledge, the work checked is i~ conformance with shop drawings dated 04-30-07 . and applicable AWS D1.1 code, except if noted above.1 Reviewed By: /l!J/;{j/f .'Dale A. Webber Structural Steel Supervisor c: Chambers Construction Co. - Brian Erickson (e-mail) Eric Hall Architects'- Steven Cho/Annette Rohde (e-mail) Endex Engineering - (e-mail) City of Springfield DAW:jw This report andlor enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific process andlor material evaluated. As such, information contained herein shall not be reproduced in part or full andlor any part thereof be disclosed without FEI Testing & Inspection, Inc.'s wrillen authorization. 750 NW Cornell Avenue' Corvallis, Oregon 97330 ' phone (541) 757-4698 ' fax (541) 757-2991 29540 BAirport Road, Eugene, Oregon 97402, phone (541) 684-3849' fax (541) 684-3851 63050 Corporate Place, Suite 2 . Bend, Oregon 97701 ' phone (541) 382-4844 . fax (541) 382-4846 L~tP~ 3 ...'1 ~~ 11:"'lh'ltl:.lI~'~UI(lJ[1IW! CLIENT Geotechnical & Construction Services Compressive Strength of Concrete (ASTM C 39) PROJECT DATE . PROJECT NO. REPORT NO. 05-30-07 2077031 5155 Ms. Silva Sullivan Chambers Development Co. 2295 Coburg Road Suite 200 Eugene, Oregon 97401 Sports Way Business Park - Ph, 2 3783 International Way Springfield, Oregon C-06-01357 DATE CAST STRENGTH REQUIRED STRENGTH PLACED PRODUCT CODE ADDITIVES LOAD NO, CONCRETE TEMP AIR TEMP POUR LOCATION LOAD 4 SAMPLED TEST DATE 05-30-07 06-20-07 06-20-07 Hold AGE (DAYS) ,7 28 28 B.P. NO. 05-23-07 CAST BY E. Marjama DATE RECEIVED 3000 psi SPECIMEN SIZE 3000 psi SACKS SUPPLIER 2144 CEMENT MAX SIZE AGG. Fiber AIR CONTENT 4 TICKET NO. 320722 SLUMP 67" F YARDAGE 10.25 OF 149,5. TIME 52' F WEATHER Clear SPECIMEN STORAGE Second floor slab -line 1 to 5, from line A to D; line 5 to 8, from A.8 to D. Approximately lines C and 2.5. AREA , (IN') 27.99 COMPRESSfVE STRENGTH (PSf) 1670 AVERAGE STRENGTH (PSI) TfME OF TEST 1:10 PM WEfGHT (LBS) 28.4 TOTAL LOAD (LBS) 46800 .. A . Cone B - Cone/Splil C - Cone Shear 0 - Shear E - Columnar REMARKS: Dave Krull (Chambers) was advised of on-site test results. Reviewed By: /J1 ,'i. /k., ----- Michael L. ~eyr Technical Manager c: Chambers Construction - Brian Erickson (e-mail) Eric Hall Architects - Steven CholAnnette Rohde (e-mail) Endex Engineering Eugene Sand and Gravel City of Springfield MLM:jm 05-24.07 6" x 12" ESG 3/4". 2.1% 41/4" 8:30 AM ASTM C31 TYPE OF FRACTURE" D This report and/or enclosed test data-is the confidential property of the client to whom it is addressed and pertains to the specific process andlor material evaluated. As such, information contained. herein shall not be reproduced in part or full and/or any part thereof be disclosed without FEI Testing & Inspection, Jne,'s written authorization. 7ffJ NW ComellAvenue' Corvallis, Oregon 97330, phone(541) 757-4698, fax (!11) 757-2991 . 29540 BAifportRoad' Eugene, Oregon 97402. phone (541) 684-3849 . fax (541)684-3851 ~~rp : ~'j'tt~ 11::"'lmtl;'II.'~;tI1ll1'1lil! Geotechnical & Construction Services Compressive Strength of Concrete (ASTM C 39) CLIENT Ms. Silva Sullivan Chambers Development Co. 2295 Coburg Road Suite 200 Eugene, Oregon 97401 PROJECT Sports Way Business Park - Ph, 2 3783 International Way Springfield, Oregon C-06-0 135 7 DATE PROJECT NO. REPORT NO. 05-30-07 2077031 5156 B.P. NO. DATE CAST 05-23-07 CAST BY E. Marjama DATE RECEIVED 05-24-07 STRENGTH REQUIRED 3000 psi SPECIMEN SIZE 6" x 12" STRENGTH PLACED 3000 psi SACKS SUPPLIER ESG PRODUCT CODE 2144 CEMENT MAX SIZE AGG. 3/4" ADDITIVES Fiber AIR CONTENT LOAD NO, 10 TICKET NO. 320750 SLUMP 41/2" CONCRETE TEMP 71" F YARDAGE 11,0 OF 149,5 TIME 10:15AM AIR TEMP 59" F WEATHER Clear SPECIMEN STORAGE ASTM C31 POUR LOCATION Second floor slab - line 1 to 5, from line A to D; line 5 to 8, from A.8 to D. LOAD 11 SAMPLED Approximately lines 5.5 and B.5, AVERAGE TEST AGE AREA WEfGHT TOTAL COMPRESSfVE STRENGTH DATE (OAYS) (fN.') (LBS) LOAD (LBS) STRENGTH IPSf) (PSI) I 05-30-07 7 27.99 28.4 56300 2010 I 06-20-07 28 I 06-20-07 28 I Hold "A Cone B-Cone/Splil C-ConeShear D-Shear E -Columnar TfM E OF TEST 1:15 PM TYPE OF FRACTURE" D REMARKS: Dave Krull (Chambers) was advised of on-site test results. Reviewed By: /JI. ~tfA(J Michael L. Mey Technical Manager c: Chambers Construction - Brian Erickson (e-mail) Eric Hall Architects - Steven Cho/Annette Rohde (e-mail) Endex Engineering . Eugene Sand and Gravel City of Springfield . MLM:jm This report and/or enclosed test data is the confidential property of the client to whom it is addressed arid pertains to the specific process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part thereof be disclosed without FEI Testing & Inspection, Inc.'s written authorization. 7WNN Cornell Avenue' Cavallis, Oregon 97330' phone (541) 757-4698, fax (541) 757-2991 29540 BAirportRoad' Eugene, Oregon 97402. phone (541) 684-J849 . fax (541)684-3851 I.~rp. ~Ittl Page 1 of 1 11:"III'I~;'II~'~aIllJi_ Geotechnical & Consbuction Services Daily Field Report Client: Ms. Silva Sullivan Project: Chambers Development Co. 2295 Coburg Road Suite 200 Eugene, Oregon 97401 Sports Way Business Park-Ph.2 3783 International Way Springfield, Oregon Date: Project No.: Report No.: Inspector: ID No.: 05-23-07 2077031 E-16344 R. Marjama 523502g~49 ICC Inspection of: Reinforced Concrete Contractor: Chambers Construction Weather: Clear BP No.: C-06-01357 Continuous Inspection: 0 Periodic Inspection: . [;'1 Performed final inspection on the reinforcing steel around perimeter and at slab openings for second floor slab line 1 to 5, from A to D and 5 to 8, from A.8 to D. Reinforcing steel was checked for grade, size,. lap, placement and clearance. Reinforcing steel was secured with tie-wire. Welded wire mesh was also in-place. Observed the placement of 149.5 cu.lyds. of Eugene Sand and Gravel's 3000 psi concrete (Mix 2144) in areas listed above. Concrete was placed by pump and was consolidated by manual screeding. Cast two (2) sets of four (4) 6" x 12" concrete test cylinders. Dave Krull (Chambers Construction) was notified of on-site test results: set 1 - slump 4 1/4"; concrete temperature 67F; air temperature 52F; air entrainment 2.1%; set 2 - slump 41/2"; concrete temperature 71 F; air temperature 59F. Mr. Krull was asked to notify our office when additional services are needed. To the best of our knowledge, the work inspected was in accordance with plans dated 03-28-07, RFI #19 dated 05-01-07 and applicable workmanship provisions of the I.B.C., except if noted above. Reviewed By: /h. ~Acr- Michael L. Meyer Technical Manager c: Chambers Construction - Brian Erickson (e-mail) Eric Hall Architects - Steven Cho/Annette Rohde (e-mail) Endex Engineering - (e-mail) City of Springfield MLM~w ( This report and/or enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific process and/Of material evaluated. As such. information contained herein shall not be reproduced in part or full and/or any part . thereof be disclosed without FEI Testing & Inspection, Inc.'s written authorization. 750 NW ComellAvenue' CoNallis, Oregon 97330, phone (541) 757-4698, fax (541)757-2991 29540 B I\jrport Road . Eugene, Oregon 97402. phone (541)684-3849 . fax (541) 684-3851 GfEl U!:'""":41,"'U!ll!Ji1W!I Geotechnical & Consbuction Services Page 1 of 1 Report of Inspection Services WeldinQ/HiQh-StrenQth BollinQ Client: Ms. Silva Sullivan Chambers Development Co. 2295 Coburg Road Suite 200 Eugene, Oregon 97401 Project: Sports Way Business Park-Ph. 2 3783 International Way Springfield, Oregon Date: Project No.: Report No.: Inspector: ID No.: 05-22-07 2077031 E-16339 C. Walpole 5114210-85 ICC Field: [;'1 Clear C-06-01357 Inspection of: Fabricator or Erector: Contractor: Welding / High Strength Bolts West Side Iron Chambers Construction Co. Shop: . 0 Weather: BP No.: Performed visual inspection on first floor to second floor brace frame connections, joist to beam connections, and rebar at perimeter bent plate (2/S2.4) on the second floor between grid lines A and D, from 1 to 8. Verified that high strength bolts were brought into tension at beam to beam and beam to column connections at second floor. Also, inspected puddle welds and button punch on sheet metal at the second floor between grid lines 1 and 6, from A to D; and between 6 and 8, from A.5 to D. Completed welds were checked for size, IEmgth, profile and location. Puddle welds were checked for size and location. Contractor was asked to notify our office when additional services are' needed. , To the best of our knowledge, the work checked is in conformance with structural drawings dated 03-28- '07, and applicable AWS D1.1 and D1.3 codes and AISC manual, except if noted above. ;;;;U/1 Dale A. Webber Structural Steel Supervisor c: Chambers Construction Co. - Brian Erickson (e-mail) Eric Hall Architects':" Steven Cho/Annette Rohde (e-mail) Endex Engineering - (e-mail) City of Springfieldv' DAW:jm This report and/or enclosed test dala is the confidential property of the client to whom it is addressed and pertains to the specific process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full andfor any part thereof be disclosed without FEI Testing & Inspection, Inc.'s written authorization. 750 NW Comell Avenue' COlVallis, Oregon 97330, phone (541) 7574698. fax (541) 757-2991 29540 BAirport Road. Eugene, Oregon 97402. phone (541)684-3849' fax (541) 684-3851 63050 Corporate Place, Suite 2 . send, Oregon 97701 . phone (541 ) 3824844 . fax (541) 3824846 I~pr. ~Itt.~ Page 1 of 1 11:"'III'It'Mllit,,~"':.IIIll'~ Geotechnical & Consbuction Services Daily Field Report Client: Ms. Silva Sullivan Project: Chambers Development Co. . 2295 Coburg Road Suite 200 Eugene, Oregon 97401 Sports Way Business Park-Ph.2 3783 International Way Springfield, Oregon Date: Project No.: Report No.: Inspector: ID No.: 05-30-07 2077031 E-16402 R. Marjama 5235029-49 Ice Inspection of: Reinforced Concrete Contractor: Chambers Construction Weather: Clear BP No.:. C-06-01357 Continuous Inspection: 0 Periodic Inspection: [;'1 Performed final inspection on the reinforcing steel around perimeter of slab and slab. openings for second. floor slab within lines 6 to 8 and A to A.8. Reinforcing steel was checked for grade, size, lap, placement and clearance. Reinforcing steel was secured with tie-wire. Welded wire mesh was also in-place. Observed the placement of 19.5 cu./yds. of Eugene Sand and Gravel 3000 psi 'concrete (Mix 144) in areas listed above. Concrete was placed by pump and was consolidated by manual screeding. Cast one (1) set of four (4) 6" x 12" concrete test cylinders. Dave Krull (Chambers Construction) was notified of on-site test results: slump 4 1/4"; concrete temperature 74F; .air temperature 60F; air entrainment 4.8%. Mr. Krull was asked to notify our office when additional services are needed. To the best of our knowledge, the work inspected was in accordance with plans dated 03-28-07, RFI #19 dated 05-01-07 and applicable workmanship provisions of the I.B.C., except if noted above. .Reviewed By: Ih.t.~ Michael L. Meyer Technical Manager c: Chambers Construction - Brian Erickson (e-mail) Eric Hall Architects - Steven Cho/Annette Rohde (e-mail) Endex Engineering - (e-mail) City of Springfield MLM:jw RECEIVED JUN 1 2 7007 This report and/or enclosed test data is the confidential property of the client to wI10m it is addressed and pertains \0 the specific process andlor material evaluated. As such. information contained herein shall not be reproduced in part or full and/or any part thereof be disclosed without FEI Testing & Inspection, Inc's written authorization. 750 f'NV Cornell Avenue' CoNallis, Oregon 97330. phone (541) 757-4698, fax(541) 757-2991 29540 BAirportRoad' Eugene, Oregon 97402. phone (541)684-3849 . fax (541) 138<hJ851 L"'PP It..ltt ~ Page 1 of 1 Report of Inspection Services Weldi nQ/HiQh-StrenQth Bolti nQ lI~'m.'ltI:.h'.'~~.IlIWllh'tliil Geotechnical & Construction Services Client: Ms. Silva Sullivan Chambers Development Co. 2295 Coburg Road. Suite 200 Eugene, Oregon 97401 Project: Sports Way Business Park-Ph. 2 3783 International Way Springfield, Oregon Date: Project No.: Report No.: Inspector: ID No.: . Inspection of: Fabricator or Erector: Contractor: Welding/High Strength Bolts West Side Iron Chambers Construction Co. Shop: O. Weather: BPNo.: 06-06-07 2077031 E-16488 L. Postier 5232606-85 ICC Field: [;'1 Overcast C-06-01357 Performed visual inspection on the second floo'r to roof brace frame connections, roof joist to beam and bridging connections and. sheet metal roof decking between line A and D, from 1 to 8. Completed welds were checked for size, length, profile and location. Puddle welds and button punch' were checked for size and location. Also,' verified the A325 high strength bolts have be'en tensioned at beam to beam and beam to column connections at roof level, between line A and D,:from 1 to 8. Erector was asked to notify our office when additional services are needed: To the best of our knowledge, the work checked is in conformance with drawings dated 03-28-07, A.I.S.C. manual and applicable AWS D1.1 and D1.3 codes, except if noted above. . Reviewed By: ~/dffi Dale A. Webber Structural Steel Supervisor c: Chambers Construction Co. - Brian 'Erickson (e-inail) . Eric Hall Architects - Steven Cho/Annette Rohde (e-mail) Endex Engineering - (e-mail) City of Springfield. DAW:jw This report and/or enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full andfor any part thereof be disclosed without FEI Testing & Inspection, Inc.'s wrillen authorization. . I 750 NW Comell Avenue' Corvallis, Oregon 97330, phone (541) 757-4698, fax (541) 757-2991 29540 B Airport Road' Eugene, Oregon 97402. phone (541)684-3849' fax (541) 684-3851 63050 Corporate Place, Suite 2. Bend, Oregon 97701 . phone (541) 382-4844. fax (541) 382-4846 {)FEJ "~'lh'lrt:.h\Io~~alllh'W! Geotechnical & Construction Services Page 1 of 1 Report of Inspection Services WeldinQ/HiQh-StrEmQth BoltinQ Client: Ms. Silva Sullivan Chambers Development Co. 2295 Coburg Road Suite 200 Eugene, Oregon 97401 Project: Sports Way Business Park-Ph. 2 3783 International Way Springfield, Oregon Date: Project No.: Report No.: Inspector: ID No.: 06-12-07 2077031 E-16078 C. Walpole 01040131 AWS CWI Field: 0 Inside C-06-01357 Inspection of: Fabricator or Erector: Contractor: Welding Gibson Steel Chambers Construction Co. Shop: [;'1 Weather: BP No.: Performed visual inspection on the following fabricated structural steel components: (9) trash enclosure gate embeds, (2) trash enclosure frames, (4) trash enclosure gates, (4) trash enclosure columns, and (2) bicycle cover frames. Completed welds were checked for size, length, profile and location. Fabricator was asked to notify our office when additional services are needed. To the best of our knowledg'e, the work checked is in conformance with shop drawings dated 05-02-07 and applicable AWS D1.1 code, except if noted above. Reviewed By: dkl(:ffi Structural Steel Supervisor c: Chambers Construction Co. - Brian Erickson (e-mail) Eric Hall Architects - Steven Cho/Annette Rohde (e-mail) Endex Engineering - (e-mail) City of Springfield DAW:jm This report andfor enclosed test data is the confidential property of the client 10 whom it is addressed and pertains 10 the specific process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full and for any part thereof be disclosed without FEI Testing & Inspection, Inc.'s wrillen authorization. 750 NW Comell Avenue' COlVallis, Oregon 97330, phone (541) 757-4698. fax (541) 757-2991 29540 BAirport Road' Eugene, Oregon 97402. phone (541) 684-3849, fax (541)684-3851 63050 Corporate Place, Suite 2 . Bend, Oregon 97701 . phone (541) 382-4844 . fax (541) 382-4846 ~~r..~ . ~~tt. Page 1 of 1 lU:'III'II'I:.I~..,~ Geotechnical & Consbuction Services Daily Field Report Client: Ms. Silva Sullivan Project: Chambers Development Co. . 2295 Coburg Road Suite 200 Eugene, Oregon 97401 Sports Way Business Park-Ph.2 3783 International Way Springfield, Oregon Date: Project No.: Report No.: Inspector: ID No.: 06-06-07 2077031 E-16489 R. Marjama 5235029-49 ICC Inspection of: Reinforcing Steel Contractor: Chambers Construction' Weather: Overcast BP No.: C-06-01357 Continuous Inspection: 0 Periodic Inspection: [;'1 Performed inspection on the reinforcing steel in two (2) HVAC mechanical pads on roof. Reinforcing steel was checked for grade, size, lap, placement and clearance. Reinforcing steel was secured with tie-wire. Concrete placement is scheduled for 9:30 AM on 06-07-07. To the best of our knowledge, the work inspected was in accordance with plans dated 03~28-07 and applicable workmanship provisions of the I.B.C., except if noted above. Reviewed By: /h.~~ Michael L ~e;i) -. . Technical Manager c: Chambers Construction - Brian Erickson (e-mail) Eric Hall Architects - Steven Cho/Annette Rohde.(e-mail) Endex Engineering - (e-mail) City of Springfield MLM:jw This report and/or enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific process and/or material evaluated. As such, information contained herein sha}1 not be reproduced in part or full andlor any part thereof be disclosed without FEI Testing & Inspection, Inc,'s written authorization. 750 NW O:xnellAvenue' CavaUis, Oregon 97330 . phone (541) 757-4698 . fax (541) 757-2991 29540 B Airport Road . Eugene, Oregon 97402 . phone (541) 684-3849 ' fax (541) 684-3851