Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 2008-6-26 Jun.26. 2008 9:03AM No.2637 P 8/13 -a engineer,ing ~ K & A Engineering, Inc. 3327 Roanoke Ave., Eugene, OR 97408 (541) 684-9399 Voice (541) 684-9358 FAX June 26, 2008 Project: 151.06 Hayden Enterprises, Inc. 2464 sw Glacier Drive #110 Redmond, OR 97756 Subject: Jasper Meadows subdlvision--Lot 239 - 57\C. MM~~' 5716 Mineral Way-Springfield, OR Foundation Soils G. ~-1ir PURPOSE AND SCOPE At your request, K & A Engifleering, Inc. has completed a geotechnical investigation of the existing soils on the subject property. Our understanding is that a wood-framed single-family residence supported by a cast-in- place concrete spread footing foundation is proposed for construction on this site. The purpose of our investigaUOn was to determine the suitability of the soils for construction of the proposed structure, and provide recommendations for construction of the foundation. The scope of our services is limited to general suitability with respect to bearing capacity and expansive soils. FOUNDATION PAD PREPARATION The project site is located on a residential lot in the Jasper Meadows subdivision in the northeast corner of the Mineral Way/South 57" Street intersection. The lot is mostly level and there are no appafent slope movement hazards, The original ground surface is low lying and is poorly drained. Based on the foundation pad excavation, native soils consist of approximately 8 to 16-inches of dark brown/black, moist, moderately stiff, organic silt, over gray/orange, wet, moderately stiff, plastic clay mixed with decomposed sandstone. Foundation preparation involved constructing a level foundation pad on a subgrade consisting of native undisturbed soils. This required excavating and removing approximately 8 to 16-inches of dark brown organic silt from the foundation pad area. Aftef the excavation and removal of the unsuitable soils, approximately 1.5 to 2.5-feet of 'I.-inch minus dense graded crushed aggregate was placed, graded, and compacted on the foundation pad. This served to provide a unifofm surface fOf footing construction at the desired elevation. The fill materials were placed and then compacted using a vibratory steel drum roller. We tested the in-place density of the 'Y<-inch minus dense graded crushed aggregate fill and have determined that the average dry density exceeds 95-percent of maximum as determined by ASTM 0698. The field test results are attached to this feport. Jun: 26 2008 9 03AM No. 2637 P. 9/13 K & A Engineering, Inc. SUMMARY AND RECOMMENDATIONS The project site, as prepared, is suitable to support the proposed foundations. We recommend a design allowable beartng capacity of 2,000-pounds per square foot. The soils present a moderate shrtnk/swell.hazard. Foundation loads should bear on undisturbed native silts a minimum depth of 36-inches below final grade around the perimeter foundation. The prepared foundation pad meets these recommendations. Final grading around the foundation pad should raise the grade above the foufldation using native or imported silts and should slope away from the foundation. We recommend approval of the foundation pad, as constructed, by the building official. Thank you for the opportunity to be of service. Please call us if you have questions or need further assistance. Steve Schultz, E.I.T. K & A Engineering, Inc. Client: Hayden Enterprises Jasper Meadows-Lot 239, Springfield, OR Project: 151.06 Page 2 of 2 June 26, 2008 Jun.26. 2008 9:03AM .' .. Density 01 Soil and Soil-Aggregates In-Place ASTM D2922 and D3D17 Proiect 151.06 Site Address: Jasper MeadowsnLot 239 Permit No: Date: 6/25/2008 Density Test Ty~e': DT-6 Operator: 55 Material Type: 3/4' (-1 from Springfield Quarry , Maximum Dry Denstiy, pcl 128.0 I Standardization and Reference Check ~ Density I (Standard Devlatlnns) (S.D.) 0.27 JA Moisture, I (S.D:) Moist' Drr' Density, Density, Water Cnmpaction, Test NO. pel pc'; Content, % % Remarks 1 140.2 134.7 4.1 105.2% 2 144.0 136.8 5.3 106.8% 3 141.5 135.3 4.6 105.7% I I I Average: 105.9% Std. Dev.: 0.83% No. 2637 P. 10/13 0.6 I Direct Transmission (DT) (specify depth, in.) or Air Gap Backscatter (AGB) {specifiy(T)ouchable or (U)ntouchable mode Test perlormed using Seaman Nuclear Corp model C-300, SN 21113 Client: Hayden Enterprises, Inc. Project: 151.06. K & A Engineering, Inc. I I I I I L I I I 6/26/2008