HomeMy WebLinkAboutPermit Field Test & Inspection Report 2008-12-15
l"'~;lInfonnation
,.,~. .To Build On
Engineering . Consulting. Testing
to\'V\? ro5- Otti-l ~
DAILY FIELD REPORT
Date Performed:
Client
December 15, 2008
Lee Construction
PO Box 10367
Eugene, OR 97401
Report Number:
722 -80 177-45
A3 - Academy of Arts &
Academics
615 Main Street
Springfield, Oregon
Project Name;
Project Location:
Fabricator/Erector;
Type of Inspection:
Metalsome Fabrications
Weiding
Shop/Field;
Weather;
Field
Inside
Field Observations and Comments
Performed periodic visual inspection of the following items: canopy in front (details 6/54, 7/54, 9/54) 6/54 framing at
curved roof, 7/S4 framing at north wail and 9/S4 tie back rod connections. Weldments were inspected for size, length,
profile and locations (attached). To the best of our knowledge, the work inspected is in conformance with approved
drawings, specifications and applicable AWS D1.1 codes, except for the following. The FOllowing items were in non-.
conformance; welds missing at (2) corners on one of the inside beam to columns. Area was marked in white
paint and will require a re-insl)ection. Contractor was asked to notify our office when additional services are needed.
Inspector; Raymond Aliperti, Certification# 1017075-86
CCB #176269
If you have any questions regarding this report, please feel free to contact us at 541-746-9649.
Respectfully Submitted,
i)~,I~_'IM
David Smith
Branch Manager
cc: City of Springfield
Branch Engineering
Solarc Architecture
Professional Underground Service
Springfield Schooi District -. John 5araceno
THIS REPORT IS PROVIDED FOR THE INFORMA TlON OF THE CLIENT aNL Y. THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD
PAi'?TY. BY ANY MEANS, EXCEPT IN FULL, WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES, IS PROHIBITED.
Professional Service Industries, Inc.. 1040-A Shelley Street. Springfield, OR 97477. Phone 541n46-9649. Fax 541n46.7163