InsulSafe@ SP
Fiber Class Blowing Insulation
CertainTeed II
Builders Statement
A (iJ CCJ IUiUC/'1 U,
Homeowner Name / Jobsile Name
~()GS h"" L,I
jOlla
Ykj~ -r,(U L.". t!
Company Name
Home Address
,
\.~~'" LU""",,
Installer / Contractor (sign)
//-6.f) 7
Date
Builder (sign)
Company Name
Date
Inspected By (sign if required)
Dale
OPEN ATTIC APPLICATION
MINIMUM
BAGS PER 1000 SQ. FT.
Bags per
1000 sq. It
01 net area:
31.4
25.2
22.4
19.1
14.9
12.8
10.8
9,3
62
5.3
MAXIMUM NET SQ. FT.
PER BAG COVERAGE
Contents 01 bag
shall ncleover
more than: (sq. fl.)
31.9
39.7
44,6
52.5
67.1
77.9
92.9
107.4
161.7
190.5
MINIMUM WEIGHT-
POUNDS PER SQ. FT.
Weighl per sq. tt. of
installed insulation shall
nOlbe less than: (Ibs.)
0.972
0.780
0.695
0.591
0.462
0.398
0.334
0.289
0.192
0.163
MINIMUM
INSTALLED THICKNESS
Inslalledinsulation
shall not be less than:
(in.)
22.00
18.50
16.75
14.50
11.75
10.25
8.75
7.75
5.25
4,50
MINIMUM
SETTLED THICKNESS
Minimum settled insulation
shalJ not be less than:
(in.)
22.00
18.50
16.75
14.50
11.75
10.25
8.75
7.75
5.25
4.50
A-VALUE
To obtain a
thermal resistance
(R) of:
60
49
44
38
30
26
22
19
13
11
I
I
I
I
I
I
'I
I
R-VALUE I
:3f I
J~h () I
THICKNESS I NET AREA (Sa. FT.) INSULSAFE SP )v) BAGS USED BATTSlROLLS (II)
/'(lfl. I Z>g?S- V 57 /
0-2.5l3'B<; I
I /
J700 I v'
I /
..3900 I
CEILINGS
WALLS
:9-1
FLOOAS
2)
THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION
. In accordance with the chart above, you must install the minimum number of bags per 1,000 sq, ft, of net area for each
R-Value listed,
. The maximum net coverage must not exceed that specified for each R-Value,
. The insulation must be installed at or above the specified installed thickness for each R-Value,
. Failure to install the required minimum weight per sq. ft, of insulation at or above the initial installed thickness will result in
reduced R-Value,
. This product should not be mixed with other blown insulations or the thermal claims will become invalid,
DANGER: RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF
SUCH DEVICES, THIS WARNING DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT
FIXTURES WITH THERMALLY PROTECTED BALLASTS,
@2007 CertainTeed Corporation
A Saint-Gobain Company
30-24-298 Builders Statement 2107
Manufacturer Insulation Fact Sheet
This is CertainTeed Corporation InsulSafe@ SP
Fiber Glass Blowing Insulation
CertainTeed Corporation
P.O, Box 860
Valley Forge, PA 19482
CertainTeed II
COVERAGE CHART-OPEN ATTIC APPLICATION
The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation
is installed with pneumatic equipment in a horizontal open blow application.
MINIMUM MAXIMUM NET sa. FT. MINIMUM WEIGHT- MINIMUM MINIMUM
A-VALUE BAGS PEA 1000 sa. FT. PER BAG COVERAGE POUNDS PER sa. FT. INSTALLED THICKNESS SETTLED THICKNESS
To obtain a Bags per Conlenls of bag Weight per sq. ft. of Installed insulation Minimum settled insulation
lhermalresislance 1000 sq. ft. shall noleaver installed insulalionshall shall not be less than: shall nol be lesslhan:
(R) of: of net area: more than: (sq. ft.) nol be less than: (Ibs.) (in.) (in,)
60 31.4 31.9 0.972 22.00 22.00
49 25.2 39.7 0.780 18.50 18.50
44 22.4 44,6 0.695 16.15 16.75
38 19.1 52.5 0.591 14.50 14.50
30 14.9 67.1 0.462 11.75 11.75
26 12.8 77.9 0.398 10.25 10.25
22 10.8 92.9 0,334 8.75 8.75
19 9,3 107.4 0.289 7.75 7.75
13 6,2 161.7 0.192 5.25 5.25
11 5,3 190.5 0.163 4.50 4.50
R-Values are determined in accordance with ASTM C687 and C518, Complies with ASTM C764 as Type 1 pneumatic
Application.
Initial installed thickness testing per ASTM C1374 using Unisul VoluMatic III; 4th gear; 15-inch gate opening; 150 ft. x
4-inch diameter internally corrugated blowing hose.
COVERAGE CHART-CLOSED CAVITY RETROFIT (WAllS, FLOORS, CEILINGS) APPLICATIONS
The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation
is installed with pneumatic equipment in sidewalls. Based on a design density of 1.6 pcf/25,6 Kglm',
R-VALUE
To obtain a
thermal resistance
(R) of:
29
22
16
15
14
REQUIRED OR MINIMUM
BAGS PER 1000 SQ. FT.
Bags per
1000 sq. fl.
of nel area:
31.2
23,7
17.2
16,1
15.1
MAXIMUM NET SQ. FT.
PER BAG COVERAGE
Contents of bag
shall not cover
morelhan: (sq. fl.)
32.1
42.3
58.1
62.0
66.4
MINIMUM WEIGHT-
POUNDS PER SQ. FT.
Weight per sq. ,ft. of
installed insulation shall
not be lesslhan: (Ibs.)
0.967
0.733
0.533
0.500
0.467
INSTALLED
THICKNESS
Installed insulation
shall not be less than:
(in.)
7.25
5.50
4.00
. 3.75
3.50
RFAD THIS BEFORE YOU BUY
What you should know about R-Values,
The chart shows the R-Value of this insulation, R means resistance to heat flow. The higher the
R-Value, the greater the insulating power, Compare insulationR-Values before you buy,
There are other factors to consider. The amount of insulation you need depends mainly on the
climate you live in, Also, your fuel savings from insulation will depend upon the climate, the type
and size of your house, the amount of insulation already in your house, and your fuel use patterns
and family size, If you buy too much insulation, it will cost you more than what you'll save on fuel.
To get the marked R-Value, it is essential that this insulation be installed properly.
@2007 CertainTeed Corporation
A Saint-Gobain Company
30-24-298 Manufacturer Fact Insulation Sheet 2107
,