Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 2008-12-16 ~fEl .",""""""""""".",. Gcv~'"lica1 & Construction Services I)(A '~\()..o~~ t ~fjLV Page 1 of 1 ~~~ Report of Inspection Services Weldinq/HiQh-StrenQth BoltinQ Client: Mr, Jim Thomas Wildish Building Co, P,O, Box 7428 Eugene, Oregon 97401 Project: LCAFRC Complex Phase II 3110 Pierce Parkway Springfield, Oregon: *Revised Report 12-24-08 Date: 12-16-08 Project No.: 2077102 Report No.: E-22039 Inspector: K, Green ID No.: 8003776 ICC Field: 0 Clear COM2007-00828 Shop: D Weather: BPNo.: Inspection of: Fabricator or Erector: Contractor: Expansion Anchors/Bolts/Hangars Wildish Building Co, Wildish Building Co, Performed continuous visual inspection during the installation of forty-six (46) horizontal Hilti KB-TZ (ICC- ES ESR 1917) 1/2" x 51/2" expansion anchors along the north and south walls of the firing range, Prior to installation, the predrilled holes were checked for minimum embedment of 4" and holes were'cleaned with compressed air and a brush, Anchors were tensioned to an installation torque of 40 ft/lbs, with a calibrated torque wrench per manufacturer's recommendations, While on-site, checked 3" x 3" x 1/4" angle splices for baffle supports in firing range (except on line 22.4) per details 9/S3, Also, per EOR verbal instructions, verified threaded rod has been installed in the hole rated for 500 Ibs, on the *Unistrut P2676 brackets attached to angles in the firing range, Tony Dean (Wildish) was asked to notify our office when additional services are needed, To the best of our knowledge, the work checked is in conformance with drawings by AZH Engineers dated 12-10-08, Reviewed By: /J1,X:~ Michael L. M"er ' Technical Manager c: 'Barrantine Bates Lee ~ (e-mail) kpff Consulting Engineers - (e-mail) Oregon Military Dept. - (e-mail) Wildish- Tony Dean (em ail) City of Springfield ' MLM:sc This report andror enclosed test data is tile confidential property of the client to whom it is addressed and pertains to the specific process andlor material evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part thereof be disclosed without FEI Testing &.Inspection, Inc.'s written authorization. .. \ 750 NW Comell Avenue' Corvallis, Oregon 97330, phone (541)757-4698 'fax(541) 757-2991 29540 B Airport Road 'Eugene, Oregon 97402, phone (541)684-3849 'fax (541)684-3851 63050 Corporate Place, Suite 2' Bend, Oregon 97701 'phone(541)382-4844' fax (541) 382-4846