Report of Inspection Services
Weldinq/HiQh-StrenQth BoltinQ
Client: Mr, Jim Thomas
Wildish Building Co,
P,O, Box 7428
Eugene, Oregon 97401
Project: LCAFRC Complex
Phase II
3110 Pierce Parkway
Springfield, Oregon:
*Revised Report 12-24-08
Date: 12-16-08
Project No.: 2077102
Report No.: E-22039
Inspector: K, Green
ID No.: 8003776
ICC
Field: 0
Clear
COM2007-00828
Shop: D
Weather:
BPNo.:
Inspection of:
Fabricator or Erector:
Contractor:
Expansion Anchors/Bolts/Hangars
Wildish Building Co,
Wildish Building Co,
Performed continuous visual inspection during the installation of forty-six (46) horizontal Hilti KB-TZ (ICC-
ES ESR 1917) 1/2" x 51/2" expansion anchors along the north and south walls of the firing range, Prior to
installation, the predrilled holes were checked for minimum embedment of 4" and holes were'cleaned with
compressed air and a brush, Anchors were tensioned to an installation torque of 40 ft/lbs, with a
calibrated torque wrench per manufacturer's recommendations,
While on-site, checked 3" x 3" x 1/4" angle splices for baffle supports in firing range (except on line 22.4)
per details 9/S3, Also, per EOR verbal instructions, verified threaded rod has been installed in the hole
rated for 500 Ibs, on the *Unistrut P2676 brackets attached to angles in the firing range,
Tony Dean (Wildish) was asked to notify our office when additional services are needed,
To the best of our knowledge, the work checked is in conformance with drawings by AZH Engineers dated
12-10-08,
Reviewed By:
/J1,X:~
Michael L. M"er '
Technical Manager
c:
'Barrantine Bates Lee ~ (e-mail)
kpff Consulting Engineers - (e-mail)
Oregon Military Dept. - (e-mail)
Wildish- Tony Dean (em ail)
City of Springfield '
MLM:sc
This report andror enclosed test data is tile confidential property of the client to whom it is addressed and pertains to the specific
process andlor material evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part
thereof be disclosed without FEI Testing &.Inspection, Inc.'s written authorization. ..
\
750 NW Comell Avenue' Corvallis, Oregon 97330, phone (541)757-4698 'fax(541) 757-2991
29540 B Airport Road 'Eugene, Oregon 97402, phone (541)684-3849 'fax (541)684-3851
63050 Corporate Place, Suite 2' Bend, Oregon 97701 'phone(541)382-4844' fax (541) 382-4846