HomeMy WebLinkAboutComments PWE 2/27/2008 Memorandum City of Springfield Date: To: February 27, 2008 Liz Miller, Planner Jesse Jones, Civil Engineer. DRC2008-000l2 Bruns Site MDS From: Subject: The Engineering Division has conducted a site visit and reviewed the materials provided with the subject application. The coinments below,are provided for your use in preparing the land-use decision. Please contact me with any questions. Site Description ' , "" : The subject site is located at the northwest corner of Main Street and 28th Street. The applicant proposes no significant changes to the existing buildings or site layout: Finding: The site is generally flat with most stormwater sheet flowing to ail existing catch basin . located near the north east comer of the site. the catch basin must be upgraded in accordance with Sections 4.3-11 O.D & E of the Springfield Development Code. Recommended Condition: To comply with Sections 4.3-11 O.D & E of the Springfield Development Code, stormwater runoff from the site will be directed into a filtered catch basin prior to discharge into the public system. This condition can be satisfied by upgrading the existing catch basin with a filter insert. j Date ReceiVed:.2..1:l.Ql . Planner: LM