Loading...
HomeMy WebLinkAboutComments PWE 10/25/2007 tAND DIVISION TENTATIVE PLAN APPLICATION PRE-SUBMITTAL CHECKLIST Engineer: Eric Walter Case#: PRE2008-00031 PUBLIC WORKS ENGINEERING Complete o Site Assessment of Existing Conditions Incomplete See PW Note(s) 1 Prepared by 'an Oregon licensed Landscape Architect or Engineer Vicinity Map The name, location, and dimensions of all existing site features including buildings, curb cuts, trees, and impervious surface areas, clearly indicating what is remaining and what is being removed. For existing stn,ictures to remain, also indicate present use and required setbacks from proposed property lines' The name, location, dimensions, direction of flow and top of bank of all watercourses and required riparian" setback that are shown on the Water Quality Limited Watercourse Map on file in the Development Services Department The 100-year floodplain and floodway boundaries on the,site, as specified in the latest adopted FEMA Flood , Ins.urance Rate Maps or FEMA approved Letter of Map Amendment or Letter of Map Revision The Time of Travel Zones, as specified in SDC 3.3-200 and delineated on the Wellhead Protection Areas Map an file in the Development Services Department Physical features including, but. not limited to trees 5" in diameter or greater when measured 4 V2 feet above the, ground, significant clusters of trees and shrubs, riparian areas, wetlands and rock outcroppings Soil types and water table information as mapped and spe,cified in the Soils Survey of Lane County. A Geotechnical Report prepared by an Engineer must be submitted concurrently if the 'Soils Survey indicates the,proposed development area has unstable soils and/or a high water table ~ l2ZR.I I25ll r:?m IZill IilliITf l!Eu ~ ~ iii Revised 10/25/07 11ftj']. E ~ 'iii ~ Iil ~ 2 ~ 2 l07'iI ~l ~ 2 o ' Land Division Tentative Plan I1ftj'] ~ ~ See PW Note(s) 3 Prepared by an Oregon licensed Land Surveyor in accordance with ORS 92 Location and width of all existing and proposed eas!,!ments on and abutting the property Boundaries of the entire area owned by the property owner, of which the proposed land division is a part, as well as dimensions and size of each parcel and the approximate dimensions of each building site indicating the top and toe of cut and fill slopes to scale Location of existing and required power, poles, transformers, neighborhood mailbox, units, and similar public facilities Location and size of existing and proposed utilities on and-adjacent to the site including sanitary sewer mains, storm water management systems, water mains, power, gas, telephone, and cable TV. Indicate the proposed connection points, 'Complete Incomplete ~ ~ 4 ~ l07'iI I.:G.Qill ~ IJ Iil ~ 5 o Stormwater Management Plan Complete Incomplete See PW Note(s) l07'iI QfLI ~ ~ ~ Prepared by, an Oregon licensed Civil Engineer, Planting plan prepared by an Oregon licensed Landscape Architect where plants are proposed as part of the stormwater management system Roof drainage patterns and discharge locations Pervious and impervious area drainage'patterns The size and location of stormwater management systems components, including but not limited to: drain lines, catch basins, dry wells and/or detention ponds; storm water quality measures; and natural drainageways to be retained ~ IJ l07'iI, ~ !V'l ~. ~ ~ ~ !V'l ~ Existing and proposed spot elevations and contours lines drawn at 1 foot intervals (for land with a slope over 10 percent, the contour lines may be at 5 foot intervals) , Amount of proposed cut and fill l07'iI ~ IZill o Stormwater Management System Study-' provide four (4) copies of the study with the completed Storm water Scoping Sheet attached. ,The plan, calculations, and Revised 10/25/07 documentation must be consistent with the Engineering Design Standards and Procedures Manual. Complete ." : Incomplete ~ /Jil PW Notes: 1. Submit a complete site assessment plan only showing existing information. This plan shall be prepared by a licensed engineer or architect as specified. Please include all existing utilities including existing storm and sanitary lines accurately shown. 2. Specified information is not summarized on the site assessment plan. 3. Submit a complete land division plan showing information required for application. 4. Specify the required 7' PUE's fronting along, both streets. 5. Clearly indicate existing and proposed utilities including storm and sanitary lines and sizes of each line. Additional comments .not related to the completeness of the, application: . An improvement agreement will be required for street improvements fronting Rainbow Drive. Revised 10/25/07