InsulSafe@4
Premium Blowing Wool
CertainTeed II
Builders Statement
f-In ",.j,. ~ .LI "''''' " ,.
Hom~owner ~ame I Jobsite Name
.!..{!)'T" "# / ~ f
~Addre~ (
I tt; ~ ( (,"''1 In.... it ~""e
InstalleriContracfor (Sign)
'"1;:,<,0 I~(o.... (!o
Company Name
Builder (sign)
Company Name
Inspected By (sign if required)
NO. OF BAGS PER MAXIMUM MINIMUM
R.VALUE 1,000 SQ, FT, NET AREA NET COVERAGE WEIGHT
To obtain a Contents of bag Weight per sq. ft,of
Thermal Aesistance No.a/Bags should not cover inslalled insulation should
(R) of: more than: (sq. fl.) not be lesslhan: (lbsJsq.ft.)
60 36.5 27 0.986
.9 29,6 3. 0,800
.. 26.4 38 0.712
38 22,8 44 0.615
30 18.0 56 0.485
26 15.5 65 0.418
22 13.1 77 0,353
19 11.1 90 0.301
13 7,7 129 0.209
11 6,6 151 0.179
R-VALUE THICKNESS AREA (50, FT,) InsulSate 4 y1
~B 1 "f '3/<{ '{i$O V
CEILINGS
..30 ~O6
WALLS
&1 /100
FLOORS
~O '200
5 '17-01
Date
Date
Date
INITIAL INSTALLED MINIMUM SETTLED '
THICKNESS THICKNESS
Should not be Should nol be
less than: leSs than:
(in.) (in.)
22,00 22.00
18.50 18.50
16.75 16.75
14.75 14.75
12.00 12.00
10.50 10.50
9.00 9,00
7.75 7.75
5.50 5.50
4.75 4.75
BAGS USED EiATTS/RDLLS (v)
/5 /
'"
/
Y'
/
t'
THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION
In accordance wifh the chart above, you mU5f in5fall fhe minimum number of bags per 1,000 sq, fj, of net area for each
R,Value listed,
The maximum net coverage must not exceed that specified for each R,Value,
. The installed insulation must be at or above the specified minimum thickness for each R-Value.
Failure to install t~e required minimum weight per sq. ft. of insulation at or above the minimum thickness will result in
reduced R-Value,
This producf should not be mixed with other blown insulafion5 or fhe fhermal claims will become invalid,
. Initial installed thickness tesfing per ASTM C 1374 using Unisul VoluMatic III; 3rd gear; 16-inch gate opening;,
150,fj, x 3,1/2 inch,diamefer internally corrugated blowing hose,
R,Value5 are determined in accordance with ASTM C 687 and C 518, Complies with ASTM C 764 as Type 1 insulafion,
"R" means resistance fo heat flow, The higher the R-Value, the greater the insulating power, To get'fhe desired
R-Value, it is essential that the insulafion is installed properly,
DANGER: RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF SUCH
DEVICES. DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH THERMALLY
PROTECTED BALLASTS,
30-24-233 InsulSafe@4 Builders Statement
A Saint-Gobain Company
@2005 CerlainTeed Corporation 11/05
Manufacturer Insulation Fact Sheet
This is CertainTeed Corporation I nsulSafe@ 4
Premium Blowing Wool
Certain Teed Corporation
P,O, Box 860
Valley Forge, PA 19482
THERMAL PERFORMANCE-HORIZONTAL OPEN BLOW
The following thermal performances are achieved at weights and coverages specified when insulation is installed with
pneumatic equipment in a horizontal cipen blow application:
NO. OF BAGS PER MAXIMUM MINIMUM INITIAL INSTALLED MINIMUM SETTLED
R-VALUE 1,000 SQ. FT, NET AREA NET COVERAGE WEIGHT THICKNESS THICKNESS
To obtain a Contents of bag Weight per sq. ft. of Should natbe Should not be
Thermal Resistance No. of Bags should not cover installed insulation should less than: less\han:
(R) or more than: (sq. fl.) natbe less than: (lbs.lsq.f1.) (in.) (in.)
60 36,5 27 0,986 22,00 22,00
49 29,6 34 0,800 18.50 18,50
44 26,4 38 0,712 16,75 16,75
38 22,8 44 0,615 14,75 14,75
30 18,0 56 0.485 12,00 12,00
26 15,5 65 0.418 10,50 10,50
22 13,1 77 0,353 9,00 9,00
19 11,1 90 0,301 7,75 7,75
13 7,7 129 0,209 5,50 5,50
11 6,6 151 0,179 4,75 4,75
R,va\ues are determined in accordance with ASTM C 687 and C 518, Complies with ASTM C 764 as Type 1 insulation,
THERMAL PERFORMANCE-SIDEWALL RETROFIT APPLICATION
When installed with pneumatic equipment in sidewall5, the following thermal performances are achieved, at the
thicknesses, weights and coverages specified, Based on a design density of 1,6 pcf/25,6 Kglm',
NO. OF BAGS PER MAXIMUM MINIMUM INITIAL. INSTALLED MINIMUM SETTLED
R-VALUE 1,000 SQ. FT. NET AREA NET COVERAGE WEIGHT THICKNESS THICKNESS
To obtain a Conlents of bag Weight persq. ft. of Should not be Should nolbe
Thermal Resistance No. of Bags should not cover installed insulation should less than: less than:
(R)ol: more than: (sq. ft.) not be less than: (Ibs.lsq. ft.) (in,) (in.)
29 35,8 28 0,967 7,25 7,25
22 27,2, 37 0,733 5,50 5,50
16 19,8 51 0,533 4,00 4,00
15 17,9 56 0.483 3,625 3,625
14 17,3 58 0.467 3,50 3,50
BEAn THIS BEFORF VOl J RI,lY
What you should know about R,Values:
The chart shows the R~Value of this insulation, R means resistance to heat flow, The higher the R,Value,
the greater the insulating power, Compare insulation R,Values before you buy,
There are other factors to consider The amount of insulation you need depends mainly on the climate
you live In, Also, your fuel savings from insulation will depend upon the climate, the type and size of your
house, the amount of insulation already in your house, and your fuel use patterns and family size, If you
buy too much insulation, it will cost you more than what you'll save on fuel.
To get the marked R,Value, it is essential that this insulation be installed properly,
\,