HomeMy WebLinkAboutPermit Correspondence 2008-3-17 1245 PEARL STREET EUGENE, OREGON 97401 PHONE (541) 484,9080 . FAX (541) 484~6859 TOll FREE 1.877-661,9959 ~1~ \AMJ laoQ3 6.rt\l{stone.. MORTIER ENGINEERING. P.C. STRUCTURAL BUILDING DESIGN. FIRE PROTECTION CODE CONSULTANT. PLAN CHECKING CONSTRUCTION INSPECTION March 17, 2008 Lucas Homes PO Box 72026 Eugene, OR 97401 RE: Lot 32 Gravstone Lo. Sorinafield. OR - Great Room Beam Uplift W,O,#: 18670-MJD As requested a structural review of the engineering packet for the residence under construction at the above address has been performed, It has been determined that (2) HTS16 straps are required at each support of the 16' long great room beam to resist uplift, The straps shall be attached to the supporting post. Uplift in the post will be resisted by repetition in the structural system, Thank you for this opportunity to be of service, If you have questions regarding this report, please contact me at 484-9080, Sincerely, Expires: 12-31- 8 Bradley R. Myers, P,E,