HomeMy WebLinkAboutBuilding Miscellaneous 2008-6-3
~ "\-\tlbD
CertainTeed II
InsulSafe@ SP
Fiber Glass Blowing Insulation
fJj) AA t! jI ~ i!f
Builders Statement
9/77- 4-/,'7t;'
Homeowner Name / JobSlte Name
Hom~ddress u. liA ~;)
fJ;lII?A~ -~#
Installer 7 Contractor (sign) "--
8uiJder (sign)
Inspected By (sign if required)
OPEN ATTIC APPLICATION
R-VALUE
Tooblain a
thermal resistance
(Rlof:
60
49
44
38
30
26
22
19
13
11
CEILINGS
WALLS
FLOORS
MINIMUM
BAGS PER 1000 sa. FT.
Bags per
1000 sq. ft.
clnet area"
31.4
25.2
22.4
19.1
14.9
12.8
10.8
9.3
6.2
5.3
!fc;~ _/ ~!L~ &A / /J f?
CompanylName D~ ~~ '-
Company Name
Date
Date
'-
MAXIMUM NET SQ. FT.
PER BAG COVERAGE
Conlenls of bag
shall no/cover
morelhan:(sq.ft,)
31.9
39.7
44.6
52.5
67.1
77.9
92.9
107.4
161.7
190.5..'
MINIMUM WEIGHT-
POUNDS PER SQ. FT.
Weighl per sq. ft. of
installed insulation shall
nolbe less than: (Ibs.)
0.972
0.780
0.695
0.591
0.462
0.398
0.334
0.289
0.192
0.163
MINIMUM
INSTALLED THICKNESS
Installed insulation
shali not be less than:
(in,)
22.00
18.50
16.75
14.50
11.75
10.25
8.75
7.75
5.25
4.50
MINIMUM
SETTLED THICKNESS'
Minimum settled insulation
shalinot be les$than:
(in.)
22.00
18.50
16.75
14.50
11.75
10.25
8.75
7.75
5.25
4.50
BATTSIROLLS (v) .
I c/'
I
I~
THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION
. In accordance with the chart above, you must install the minimum number of bags per 1,000 sq. ft. 01 net area for each
R-Value listed.
. The maximum net coverage must not exceed thai specified for each R-Value.
. The insulation must be installed at or above the specified installed thickness for each R-Value.
. Failure to install the required minimum weight per sq. ft of insulation at or above the initial installed thickness will result in
reduced R-Value.
. This product should not be mixed with other blown insulations or the thermal claims will become invalid.
R-VALUE THICKNESS NET AREA (sa. FT.) INSULSAFE SP (v) BAGS USED
?8 14-~ 1//)0 ~ :d4-
9-.1 5'~ 1)76'8
I
~lJ fj Ild6e
I
DANGER: RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF
SUCH DEVICES_ THIS WARNING DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT
FIXTURES WITH THERMALLY PROTECTED BALLASTS.
@2007 CertainTeed Corporation
A Saint-Gobain Company
30-24-29B Builders Statement 2/07
Manufacturer Insulation Fact Sheet
This is CertainTeed Corporation InsulSafe@ SP
Fiber Glass Blowing Insulation
CertainTeed II
CertainTeed Corporation
P.O. Box 860
Valley Forge, PA 19482
COVERAGE CHART-OPEN ATTIC APPLICATION
The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation
is installed with pneumatic equipment in a horizontal open blow application.
MINIMUM MAXIMUM NET SQ. FT. MINIMUM WEIGHT- MINIMUM MINIMUM
R-VALUE BAGS PER 1000 SQ. FT. PER BAG COVERAGE POUNDS PER SQ. FT. INSTALL.ED THICKNESS SETTLED THICKNESS
Tooblain a Bags per Conlents of bag Weight per sq. ft.of Installed insulation Minimum settled insulation
thermal resistance 1000 sq. It. shall not cover inslalled insulation shall shall not be lesslhan: shall nol be lesslhan:
(R) of: of nel area: more than: (sq, ft.) nol be less than: (Ibs.) (in.) {in.}
60 31.4 31.9 0.972 22,00 22.00
49 25.2 39.7 0.780 18.50 18.50
44 22.4 44.6 0.695 16.75 16.75
38 19.1 52.5 0.591 14.50 14.50
30 14.9 67.1 0.462 11.75 11.75
26 12.8 77.9 0.398 10.25 10.25
22 10.8 92.9 0.334 8.75 8.75
19 9.3 107.4 0.289 7.75 7.75
13 6.2 161.7 0.192 5.25 5.25
11 5.3 190.5 0.163 4.50 4.50
R-Values are determined in accordance with ASTM C687 and C518. Complies with ASTM C764 as Type 1 pneumatic
Application.
Initial installed thickness testing per ASTM C1374 u5ing Unisul VoluMatic III; 4th gear; 15-inch gate opening; 150 It. x
4-inch diameter internally corrugated blowing hose.
COVERAGE CHART-ClOSED CAVITY RETROFIT (WAllS, flOORS, CEILINGS) APPLICATIONS
The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation
is installed with pneumatic equipment in sidewalls. Based on a design density of 1.6 pcf/25.6 Kg/m3
I REQUIRED OR MINIMUM MAXIMUM NET sa. FT. MINIMUM WEIGHT- INSTAllED
R-VAlUE BAGS PER 1000 SQ. FT. PER BAG COVERAGE POUNDS PER sa. FT. THICKNESS
To obtain a I Bags per Contents olbag Weighl per sq. ft. 01 Installed insulation
thermal resistance 1000 sq. ft. shall not cover installed insulation shall shall nolbe less than:
(R}ol: ofne! area: more than: (sq. ft.) not be less than: (Ibs.) (in.)
29 I 31.2 32.1 0.967 7.25
22 I 23.7 42.3 0.733 5.50
16 17.2 58.1 0.533 4.00
15 16.1 62.0 0.500 3.75
14 I 15.1 66.4 0.467 3.50
READ THIS BEFORE YOU BUY
What you should know about R-Values.
The chart shows the R-Value of this insulation. R means resistance to heat flow. The higher the
R-Value, the greater the insulating power. Compare insulation R-Values before you buy.
There are other factors to consider. The amount of insulation you need depends mainly on the
climate you live in. Also, your fuel savings from insulation will depend upon the climate, the type
and size of your house, the amount of insulation already in your house, and your fuel use patterns
and family size. If you buy too much insulation, it will cost you more than what you'll save on fuel
To get the marked R-Value, it is essential that this insulation be installed properly.
<<;>2007 CertainTeed corporation
A Saint-Gobain Company
30-24-298 Manufacturer Fact Insulation Sheet 2/07