Loading...
HomeMy WebLinkAboutBuilding Miscellaneous 2008-4-10 CertainTeed II Builders Statement &'~s'n'te <u Ida S' -.... HOign~ N"ie I Jz;:e:~ 1__ rIa^ Home Address - 0(cl^ <'";);-ll Atwv Installer I Contractor (sign) Builder (sign) Inspected By (sign if required) OPEN ATTIC APPLICATION R-VALUE To obtain a thermal resistance (R) of: 60 49 44 38 30 26 22 19 13 11 CEILINGS WALLS FLOORS MINIMUM BAGS PER 1000 sa. FT. Bags per 1QOOsq. It olne! area: 31.4 25.2 22.4 19.1 14.9 12.8 10.8 9.3 6.2 53 (\.~ ~ InsulSafe@ SP Fiber Glass Blowing Insulation r;., J lA- /~-~ r!o Company Name MAXIMUM NET sa. FT. PER BAG COVERAGE: Conlents ot bag shall notcov8r morelhan: (sq. ft.) 31.9 39.7 44.6 52.5 67.1 77.9 92.9 107.4 161.7 190.5 Company Name MINIMUM WEIGHT- POUNDS PER sa. FT. Weight per sq. ft. of installed insulation shall nolbe lesslhan: (Ibs.) 0.972 0.780 0.695 0.591 0.462 0.398 0.334 0.289 0.192 0.163 . 1'- /{)--cJ P Date Date Date MINIMUM INSTALLED THICKNESS Installed insulation shall not be less than: {in.} 22.00 18.50 16.75 14.50 11.75 10.25 8.75 7.75 5,25 4.50 MINIMUM SEnLED THICKNESS Minimum settled insulation shall not be less than: (in.) 22.00 18.50 16.75 14.50 11.75 10.25 8.75 7.75 5.25 4.50 R.VAlOE THICKNESS NET AREA (SQ. FT.~ INSULSAFE SP (II) BAGS USED BATTSJROl.LS (v) ':>8 ;I.{.'Il.. ZSo ( Co / ...'> .?'l '2:"2- 0 THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION . In accordance wilh the chart above, you musl install the minimum number of bags per 1,000 sq. ft. of nel area for each R-Value listed. . The maximum net coverage musl not exceed that specified for each R-Value. . The insulation must be installed at or above the specified installed thickness for each R-Value. . Failure to install the required minimum weight per sq. ft. of insulation at or above the initial installed thickness will result in reduced R-Value. . This product should not be mixed with other blown insulations or the thermal claims will become invalid. DANGER: RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF SUCH DEVICES. THIS WARNING DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH THERMALLY PROTECTED BALLASTS_ @2007 CertainTeed Corporation A Saint-Gobain Company 30-24.298 Builders Statement 2107 ~,'" ::'. r -- Manufacturer Insulation Fact Sheet This is CertainTeed Corporation InsUlISafe@ SP Fiber Glass Blowing Insulation CertainTeed Corporation P.O. Box 860 Valley Forge, PA 19482 CertainTeed II COVERAGE CHART-OPEN ATTIC APPLICATION The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation is installed with pneumatic equipment in a horizontal open blow application. MINIMUM MAXIMUM NET SQ. FT. MINIMUM WEIGHT- MINIMUM MINIMUM R-VALUE BAGS PER 1000 SQ. FT. PER BAG COVERAGE POUNDS PER SQ. FT. INSTALLED THICKNESS SETTLED THICKNESS To obtain a Bags per Contents of bag Weight per sq. ft,of Installed insulation Minimum settled insulation lhermalresistance 1000 sq. It, shall not cover installed insulation shall shall nol be less than: shall not be less than: (Alof: olne! area: more than: (sq. ft.) not be lesslhan: (Ibs.) (in.) (In.) 60 31.4 31.9 0.972 22,00 22.00 49 25.2 39.7 0.780 18.50 18.50 44 22.4 44.6 0.695 16.75 16.75 38 19.1 52.5 0.591 14.50 14.50 30 14.9 67,1 0.462 11.75 11.75 26 12.8 77.9 0.398 10.25 10.25 22 10.8 92.9 0.334 8.75 8,75 19 9.3 107.4 0.289 7,75 7,75 13 6.2 161.7 0,192 5.25 5.25 11 5.3 190.5 0,163 4.50 4.50 R-Values are determined in accordance with ASTM C687 and C518. Complies with ASTM C764 as Type 1 pneumatic Application. Initial installed thickness testing per ASTM C1374 using Uni5ul VoluMatic III; 4th gear; 15-inch gate opening; 150 ft. x 4-inch diameter internally corrugated blowing hose. COVERAGE CHART-CLOSED CAVITY RETROFIT (WALLS, flOORS, CEILINGS) APPLICATIONS The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation is installed with pneumatic equipment in sidewalls. Based on a design density of 1.6 pcf/25.6 Kglm3 REQUIRED OR MINIMUM MAXIMUM NET SQ. FT. MINIMUM WEIGHT- INSTALLED R-VALUE BAGS PER 1000 SQ. FT. PER BAG COVERAGE POUNDS PER SQ. FT. THICKNESS To obtain a 8agsper Contents 01 bag Weighl per sq. ft. of Installed insulation lhermalresistance 1000 sq. ft. shall not cover installed insulation shall shall not be less than: (RloC of net area: more than: (sq. ft.) not be less than: (Ibs.) (in.) 29 31.2 32.1 0.967 7.25 22 23.7 42.3 0.733 5.50 16 17.2 58.1 0.533 4.00 15 16.1 62,0 0.500 3.75 14 15.1 66.4 0.467 3.50 READ THIS BEFORE YOU BUY What you should know about R-Values. The chart shows the R-Value of this insulation. R means resistance to heat flow. The higher the R-Value, the greater the insulating power. Compare insulation R-Values before you buy. There are other factors to consider. The amount of insulation you need depends mainly on the climate you live in. Also, your fuel savings from insulation will depend upon the climate, the type and size of your house, the amount of insulation already in your house, and your fuel use patterns and family size. If you buy too much insulation, it will cost you more than what you'll save on fuel. To get the marked R-Value, it is essential that this insulation be installed properly 1&)2007 CertainTeed Corporation A Sainl-Gobain Company 30-24~298 Manufacturer Fact Insulation Sheet 2107