HomeMy WebLinkAboutBuilding Miscellaneous 2008-2-20 ',~ 1 ~rl"'\~ CertainTeed II Builders Statement '-, InsulSafe@ SP Fiber Glass Blowing Insulation - 'J)u K'. < 4: t::>v,k".. c; Homeowner Name / Jobsite Name J '0 IJ I Sqi~ S t Home Addre~ I ~:1 I~ I~? Installer I Contractor (~ign) r/61'V 1"11511 /rn 10", to Company Nal}le . ,;} -,;20 - tJ Y' Date Dale Company Name Builder (sign) Date Inspected By (sign if required) OPEN ATTIC APPLICATION . MINIMUM SETIlED THICKNESS Minfmum settJed insulation shall not be less than: (in.) 22.00 18.50 16.75 14.50 11.75 10.25 8.75 7.75 5.25 4.50 MINIMUM INSTALLED THICKNESS Installed insulation shall nol be less than: (in.) 22.00 18.50 16.75 14.50 11.75 10.25 8.75 7.75 5.25 4.50 ' MINIMUM WEIGHT- POUNDS PER sa. FT. Weighlper sq. tt.of installed insulalionshall not be less than: (Ibs.) 0.972 0.780 0.695 0.591 0.462 0.398 0.334 0.289 0.192 0.163 MAXIMUM NET sa. FT. PER BAG COVERAGE Contents of bag shall not cover more than: (sQ. ft.) 31.9 39.7 44.6 52,5 67.1 77.9 92.9 107.4 161.7 190.5 MINIMUM BAGS PER 1000 SQ. FT. Bags per 1000 sQ. fl. of net area: 31.4 25,2 22.4 19.1 14.9 12.8 10.8 9.3 6.2 5.3 R-VALUE To obtain a thermal resistance (R) ot: 60 49 44 38 30 26 22 19 13 11 I: R-VALUE THICKNESS NET AREA (SQ. FT.) INSULSAFE 5.1(.....) BAGS USED BATTSJROLLS (.....) s8 I'I'/l (,75 V 1_5 / 3'6-30 /0 -450 , ~, J/~() /' CEILINGS WALLS FLOORS ,. ~/ THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION \ . \ ' . In accordance with the chart above, you must install the minimum number of bags per 1,000 sq. ft. of net area jor each R-Value listed. ' . The maximum net coverage must not exceed that specified for each R-Value. . The insulation must be installed at or above the specified installed thickness for each R-Value. . Failure to Install the required minimum weight per sq. ft. of insulation at or above the initial installed thickness will result in reduced R-Value. '- . This product should not be mixed with other blown insulations or the thermal claims will become invalid. < DANGER: RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF SUCH DEVICES. THIS WARNING DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH THERMALLY PROTECTED BALLASTS_ /~ 30-24-298 Builders Statement 2107 A Saint-Gobain Company C2007 CertainTeed Corporation ~ /' Manufacturer " ~.-. . -,' .... .,.. --- Insulation Fact Sheet InsulSafe@ SP This is CertainTeed Corporation Fiber Glass Blowing Insulation CertainTeed Corporation P.O. Box 860 Valley Forge, PA 19482 CertainTeed II COVERAGE CHART-OPEN ATTIC APPLICATION The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation is installed with pneumatic equipment in a horizontal open blow application. MINIMUM MAXIMUM NET sa. FT. MINIMUM WEIGHT- MINIMUM MINIMUM R.VAlUE BAGS PEA 1000 SQ. FT. PER BAG COVERAGE POUNDS PER sa. FT. INSTALLED THICKNESS SETTLED THICKNESS Tooblain a Bags per Contents of bag Weight per sq. It 01 Installed insulation Minimum.settled insulation thermal resistance 1000 sq. ft. shall not cover inslalledinsulalion shall shall natbe lesslhan: shall nol be less lhan: (Rlcl: of net area: morelhan: (sq. ft) not be lesslhan: (1bs.) (In.) (in.) 60 31.4 31.9 0.972 22,00 22.00 49 25.2 39.7 0.780 18,50 18,50 44 22.4 44.6 0.695 16.75 16.75 38 19.1 52.5 0.591 14.50 14.50 30 14.9 67.1 0.462 11.75 11.75 26 12.8 77.9 0.398 10.25 10.25 22 10.8 92.9 0334 8.75 8.75 19 9.3 107.4 0.289 7.75 7.75 13 6.2 161.7 0.192 5.25 5,25 11 5.3 190.5 0,163 4.5D 4.50 R-Values are determined in accordance with ASTM C687 and C518. Complies with ASTM C764 as Type 1 pneumatic r" Application. Initial installed thickness testing per ASTM C1374 using Unisul VoluMatic III; 4th gear; 15-inch gate opening; 150 ft. x 4-inch diameter internally corrugated blowing hose. COVERAGE CHART-CLOSED CAVITY RETROFIT (WALLS, FLOORS, CEILINGS) APPLICATIONS The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation is installed with pneumatic equipment in sidewalls. Based on a design density of) .6\pcf/25.6 Kglm] R-VALUE Toobtain'a thermal resistance (R)of: 29 22 16 15 14 I REQUIRED OR MINIMUM BAGS PER 1000 SQ. FT. Bags per 1000 sq. fl. of net area: 31.2 23.7 17.2 16.1 15.1 MINIMUM WEIGHT- POUNDS PER SQ. FT. Weight per sq. fl. of installed insulation shall not be lesslhan: (Ibs.) 0.967 0.733 0.533 0.500 0.467 MAXIMUM NET SQ. FT. PER BAG COVERAGE Contenls of bag shall not cover more than: (sq. ft.) 32.1 42.3 58.1 62.0 66.4 INSTALLED THICKNESS Installed insulation shall not be less than: (in.) 7,25 5.50 4.00 3.75 3.50 READ THIS BEFORE YOU BUY What you should know about R-Values. The chart shows the R-Value of this insulation. R means resistance to heat flow. The higher the R-Value, the greater the insulating power. Compare insulation R-Values before you buy. There are other factors to consider. The amount of insulation you need depends mainly on the climate you live in. Also, your fuel savings from insulation will depend upon the climate, the type' -and size of your house, the amount of insulation already in your house, and your fuel use patterns and family siz~. If you buy too much insulation, it will cost you more than what you'll save on fuel. To get the marked R-Value, it is essential that this insuiation be installed properly. @2007 CertainTeed Corporation - ~- A Saint-Gobain Company -:- '? 3O--24-29B Manufacturer Fact Insulation Sheet 2107 --