Builders Statement
'-,
InsulSafe@ SP
Fiber Glass Blowing Insulation
-
'J)u K'. < 4: t::>v,k".. c;
Homeowner Name / Jobsite Name
J '0 IJ I Sqi~ S t
Home Addre~ I
~:1 I~ I~?
Installer I Contractor (~ign)
r/61'V 1"11511 /rn 10", to
Company Nal}le
. ,;} -,;20 - tJ Y'
Date
Dale
Company Name
Builder (sign)
Date
Inspected By (sign if required)
OPEN ATTIC APPLICATION
. MINIMUM
SETIlED THICKNESS
Minfmum settJed insulation
shall not be less than:
(in.)
22.00
18.50
16.75
14.50
11.75
10.25
8.75
7.75
5.25
4.50
MINIMUM
INSTALLED THICKNESS
Installed insulation
shall nol be less than:
(in.)
22.00
18.50
16.75
14.50
11.75
10.25
8.75
7.75
5.25
4.50 '
MINIMUM WEIGHT-
POUNDS PER sa. FT.
Weighlper sq. tt.of
installed insulalionshall
not be less than: (Ibs.)
0.972
0.780
0.695
0.591
0.462
0.398
0.334
0.289
0.192
0.163
MAXIMUM NET sa. FT.
PER BAG COVERAGE
Contents of bag
shall not cover
more than: (sQ. ft.)
31.9
39.7
44.6
52,5
67.1
77.9
92.9
107.4
161.7
190.5
MINIMUM
BAGS PER 1000 SQ. FT.
Bags per
1000 sQ. fl.
of net area:
31.4
25,2
22.4
19.1
14.9
12.8
10.8
9.3
6.2
5.3
R-VALUE
To obtain a
thermal resistance
(R) ot:
60
49
44
38
30
26
22
19
13
11
I:
R-VALUE THICKNESS NET AREA (SQ. FT.) INSULSAFE 5.1(.....) BAGS USED BATTSJROLLS (.....)
s8 I'I'/l (,75 V 1_5 /
3'6-30 /0 -450
,
~, J/~() /'
CEILINGS
WALLS
FLOORS
,. ~/
THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION \ .
\ '
. In accordance with the chart above, you must install the minimum number of bags per 1,000 sq. ft. of net area jor each
R-Value listed. '
. The maximum net coverage must not exceed that specified for each R-Value.
. The insulation must be installed at or above the specified installed thickness for each R-Value.
. Failure to Install the required minimum weight per sq. ft. of insulation at or above the initial installed thickness will result in
reduced R-Value. '-
. This product should not be mixed with other blown insulations or the thermal claims will become invalid.
<
DANGER: RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF
SUCH DEVICES. THIS WARNING DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT
FIXTURES WITH THERMALLY PROTECTED BALLASTS_ /~
30-24-298 Builders Statement 2107
A Saint-Gobain Company
C2007 CertainTeed Corporation
~ /'
Manufacturer
"
~.-. .
-,'
....
.,..
---
Insulation Fact Sheet
InsulSafe@ SP
This is CertainTeed Corporation
Fiber Glass Blowing Insulation
CertainTeed Corporation
P.O. Box 860
Valley Forge, PA 19482
CertainTeed II
COVERAGE CHART-OPEN ATTIC APPLICATION
The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation
is installed with pneumatic equipment in a horizontal open blow application.
MINIMUM MAXIMUM NET sa. FT. MINIMUM WEIGHT- MINIMUM MINIMUM
R.VAlUE BAGS PEA 1000 SQ. FT. PER BAG COVERAGE POUNDS PER sa. FT. INSTALLED THICKNESS SETTLED THICKNESS
Tooblain a Bags per Contents of bag Weight per sq. It 01 Installed insulation Minimum.settled insulation
thermal resistance 1000 sq. ft. shall not cover inslalledinsulalion shall shall natbe lesslhan: shall nol be less lhan:
(Rlcl: of net area: morelhan: (sq. ft) not be lesslhan: (1bs.) (In.) (in.)
60 31.4 31.9 0.972 22,00 22.00
49 25.2 39.7 0.780 18,50 18,50
44 22.4 44.6 0.695 16.75 16.75
38 19.1 52.5 0.591 14.50 14.50
30 14.9 67.1 0.462 11.75 11.75
26 12.8 77.9 0.398 10.25 10.25
22 10.8 92.9 0334 8.75 8.75
19 9.3 107.4 0.289 7.75 7.75
13 6.2 161.7 0.192 5.25 5,25
11 5.3 190.5 0,163 4.5D 4.50
R-Values are determined in accordance with ASTM C687 and C518. Complies with ASTM C764 as Type 1 pneumatic
r" Application.
Initial installed thickness testing per ASTM C1374 using Unisul VoluMatic III; 4th gear; 15-inch gate opening; 150 ft. x
4-inch diameter internally corrugated blowing hose.
COVERAGE CHART-CLOSED CAVITY RETROFIT (WALLS, FLOORS, CEILINGS) APPLICATIONS
The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation
is installed with pneumatic equipment in sidewalls. Based on a design density of) .6\pcf/25.6 Kglm]
R-VALUE
Toobtain'a
thermal resistance
(R)of:
29
22
16
15
14
I REQUIRED OR MINIMUM
BAGS PER 1000 SQ. FT.
Bags per
1000 sq. fl.
of net area:
31.2
23.7
17.2
16.1
15.1
MINIMUM WEIGHT-
POUNDS PER SQ. FT.
Weight per sq. fl. of
installed insulation shall
not be lesslhan: (Ibs.)
0.967
0.733
0.533
0.500
0.467
MAXIMUM NET SQ. FT.
PER BAG COVERAGE
Contenls of bag
shall not cover
more than: (sq. ft.)
32.1
42.3
58.1
62.0
66.4
INSTALLED
THICKNESS
Installed insulation
shall not be less than:
(in.)
7,25
5.50
4.00
3.75
3.50
READ THIS BEFORE YOU BUY
What you should know about R-Values.
The chart shows the R-Value of this insulation. R means resistance to heat flow. The higher the
R-Value, the greater the insulating power. Compare insulation R-Values before you buy.
There are other factors to consider. The amount of insulation you need depends mainly on the
climate you live in. Also, your fuel savings from insulation will depend upon the climate, the type'
-and size of your house, the amount of insulation already in your house, and your fuel use patterns
and family siz~. If you buy too much insulation, it will cost you more than what you'll save on fuel.
To get the marked R-Value, it is essential that this insuiation be installed properly.
@2007 CertainTeed Corporation
- ~-
A Saint-Gobain Company -:-
'?
3O--24-29B Manufacturer Fact Insulation Sheet 2107
--