Loading...
HomeMy WebLinkAboutBuilding Miscellaneous 2007-7-25 (2) CertainTeed-1I Builders Statement 32'1:6-:" 328<;/ 11-5 fer sr , Homeowner t ., me I Jobsite Name _. p,-eJd Of- t'_m,/lA- Installer / Contractor (sign) Builder (sign) 0~ '1-304 InsulSafe@ SP Fiber Glass Blowing Insulation 71:1._S/07 .oate / Company Name Home Insulation Contractors Inc. 3415S liwv 9.Q.F T "';.g.....,,(D~73139 Builders Board #85~ Inspected By (sign if required) OPEN ATTIC APPLICATION A-VALUE To obtain a thermal resistance (R)of: 60 49 44 (~1j?' 30 26 22 19 13 11 CEILINGS WALLS FLOORS MINIMUM B,(GS PER 1000 SQ. FT. Bags per 1000 sq. ft. of nel area: 31.4 25.2 22.4 19.1 14.9 12.8 10.8 9.3 6.2 5.3 MAXIMUM NET sa. FT. PER BAG COVERAGE Contents of bag shall not cover morelhan:{sq. ft.) 31.9 39.7 44.6 52,5 67.1 n9 92.9 107.4 161.7 190.5 I I. I I I I I .'-1 1 MINIMUM WEIGHT- POUNDS PEA sa. FT. Weighl per sq. ft. of installed insulation shall nolbe lesslhan: (Ibs.) 0.972 0.780 -.0,695 .0,591 0.462 0.398 0.334 0.289 0.192 0.163 NET AREA (SQ. FT.) I INSUlSAF.E SP (v) Date Date MINIMUM INSTALLED THICKNESS Installed insulation shall not be less Ihan: (in.) 22.00 18.50 16.75 14.50.';,1, 11.75 10.25 8.75 7.75 5.25 ~' 4.50-, . BAGS USED 'MINIMUM , SETTLED THICKNESS Minimum settled insulation shall not be less than: (in.) 22.00 18.50 16.L\.. <:. !-4SOl.! 1T75 10.25 8.75 7.75 5.25 4.50 I I I I, I I I I I I BATTSlROLLS (V') I I I .... -- ....-- - THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION In accordance with the chart above, you must install the minimum number of bags per 1,000 sq. ft. of net area for each R-Value listed. . The maximum net coverage must not exceed that specified for each R-Value. . The insulation must be installed at or above the specified installed thickness for each R-Value. . Failure to install the required minimum weight per sq. ft of insulation at or above the initiai installed thickness will result in reduced R-Value. . This product should not be mixed with other blown insulations or the thermal claims will become invalid. R-VALUE THICKNESS DANGER: RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF SUCH DEVICES_ THIS WARNING DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH THERMALLY PROTECTED BALLASTS_ @2007 CertainTeed Corporation A Saint-Gobain Company 30-24-298 Builders Statement 2107 Manufacturer Insulation Fact Sheet This is CertainTeed Corporation InsulSafe@ SP Fiber Glass Blowing Insulation CertainTeed Corporation P.O. Box 860 Valley Forge, PA 19482 CertainTeed 1:-1 COVERAGE CHART-OPEN ATTIC APPLICATION The following thermal performances are achieved at the thicknesses, weights and coverages specified when 1 ,ulation is installed with pneumatic equipment in a horizontal open blow application. ' MINIMUM MAXIMUM NET SQ. FT. MINIMUM WEIGHT- MINIMUM MINIMUM A-VALUE BAGS PER 1000 sa. FT. PER BAG COVERAGE POUNDS PER sa, FT. INSTALLED THICKNESS SETTLED THICKNESS Tooblain a Bags per Conlenls 01 bag Weight per sq. ft. of Inslalledinsulation Minimum settled insulation thermal resistance 1000 sq. ft. shall noleover installed insulation shall shall not be less than: shall nalbe less than: (R)of: of net area: more than: (sq. ft.) nol be less than: (lbs.) (in.) (in.) 60 31.4 31.9 0.972 22.00 22.00 49 25.2 39.7 0.780 18.50 18.50 44 22.4 44.6 0.695 16.75 16.75 38 19.1 52.5 0.591 14.50 14.50 30 14.9 67.1 0.462 11.75 11.75 26 12.8 77.9 0.398 10.25 10.25 22 10.8 92.9 0.334 8.75 8.75 19 93 107.4 0.289 7.75 7.75 13 62 161.7 0.192 5.25 5.25 11 5.3 190.5 0.163 4.50 4.50 R-Values are determined in accordance with ASTM C687 and C518. Complies with ASTM C764 as Type 1 pneumatic Application. Initial installed thickness testing per ASTM C1374 using Unisul VoluMatic III; 4th gear; 15-inch gate opening; 150 ft. x 4-inch diameter internally corrugated blowing hose. COVERAGE CHART-CLOSED CAVITY RETROFIT (WALLS, FLOORS, CEILINGS) APPLICATIONS The following thermal perfornian~es are achieved at the thicknesses, weights and coverages specified when insulation is installed with pneumatic equipment in sidewalls. Based on a design density of 1.6 pcf/25.6 Kglm3 R.VALUE REQUIRED OR MINIMUM BAGS PER 1000 sa. FT. Bags per 1000 sq. ft. of net area: 3"1.2 23.7 MAXIMUM NET sa. FT. PER BAG COVERAGE Conlentsof bag shall not cover more than: (sq. ft.) 32.1 42.3 58.1 62.0 66.4 MINIMUM WEIGHT- POUNDS PER SQ. FT. Weight per sq. ft. of installed insulation shall nol be less than: (Ibs.) 0.967 0.733 0.533 0.500 0.467 Tooblain a thermal resistance (Rlof: 29 22 16 ,,,-, 14 ~""-'2 1:.1 --.' -. "'1 .'. .:J.1 INSTALLED THICKNESS Installed insulation shall not be less than: (in.) 7,25 5.50 4.00 3.75 3.50 READ THIS BEFORE YOU BUY What you should know about R-Values. The chart shows the R-Value of this insulation. R means resistance to heat flow. The higher the R-Value, the greater the insulating power. Compare insulation R-Values before you buy. There are other factors to consider The amount of insulation you need depends mainly on the climate you live in. Also, your fuel savings from insulation will depend upon the climate, the type and size of your house, the amount of insulation already in your house, and your fuel use patterns and family size. If you buy too much insulation, it will cost you more than what you'll save on fuel. To get the marked R-Value, it is essential that this insulation be installed properly. @2007 CertainTeed Corporation A Saint-Gobain Company 30-24-298 Manufacturer Fact Insulation Sheet 2107