Loading...
HomeMy WebLinkAboutBuilding Miscellaneous 2007-7-25 CertainTeed II Builders Statement , .k;l~6 - .~ 2 <P'j{ IJs ~y S+- a..<. Homeowner Name I Jobsite Nam~ / Sbr /~ :/";e- k;f , Ho:"e~~ I)$~' Installer I Contra'ctOf (sign) ~ (\"1"~~ InsulSafe@ SP Fiber: Glass Blowing Insulation 'Date 7J~107 Builder (sign) i- Company Name Home Insulation Contractors Inc. ::I.415!\ f1wy R'lE TImg8nt.~97389 Builders Board #85 Inspected By (sign if required) OPEN ATTIC APPLICATION R-VALUE To oblain a thermal resistance IR)ol: 6() 49 44 ~ I MINIMUM BAGS PER 1000 SQ. FT. Bags per 1000 sQ. ft. of nel area: 31.4 I ,\G~:___,__: 19.1 I 14.9 .;" I 12.V l'tJ:a-. 9.3 6.2 5.3 MAXIMUM NET SQ. FT. PER BAG COVERAGE Contents of bag shall notcov8r more than: (SQ. ft.) 31.9 39.7 44.6 52.5 67.1 77.9 92.9 107.4 161.7 190.5 26 22 19 13 11 " A-VALUE'i' ....y . THICKNESS CEILINGS ,-.f WALLS FLOORS MINIMUM WEtGHT- POUNDS PER sa. FT. weighipersq~lt.'c. installed insulation shall not be less than: (Ibs.) 0.972 0.780 0.695 0.591 0.462 0.398 0.334 0.289 0.192 0.163 NET AREA (sa. FT.) INSULSAFE SP (.....) Date Date MINIMUM INSTALLED THICKNESS InslaJledinsulalion shall not be less than; (in.) 22.00 18.50 16.75 14.50 11.75 10.25 8.75 7.75 5.25 4.50 BAGS USED MINIMUM ,SETTLED THICKNESS Minimum settied'insulalion shalJnolbe'lessthan;"o. (in.) ".' 22.00 18.50 16~Z~ (14 sO'/! I 1r.75 I 10.25 I 8.75, r 7.75 oil 5.25 I 4.50 ,.. I '~~'I, I ., ," I I I I BATTSlRO{LS (.....) . , ~ '.O'N~ ._..._;.,f:f:-i_:~~; : '" .'./~':: . ~ .... -, THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION . In accordance with the chart above, you must install the minimum number of bags per 1,000 sq. ft of net area for each R-Value listed. " . . The maximum net coverage must not exceed that specified for each R,Value. The insuiation must be installed at or above the specified installed thickness for each R-Value. . Failure to install the required minimum weight per sq: ft of insulation at or above the initial installed thickness will result in reduced R-Value. . . This product should not be mixed with other blown insulations 'or the thermal claims will become inwilid. DANGER: RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF SUCH DEVICES, THIS WARNING DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH THERMALLY PROTECTED BALLASTS, @2007 CertainTeed Corporation A Sainl-Gobain Company 30-24-298 Builders Statement 2/07 '.. #'.0" " .. .., . ,J." . Manufacturer Insulation Fact Sheet This is CertainTeed Corporation InsulSafe@ SP Fiber Glass Blowing Insulation CertainTeed Corporation P.O. Box 860 Valley Forge, PA 19482 CertainTeed 1:-1 COVERAGE CHART-OPEN ATTIC APPLICATION The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation is installed with pneumatic equipment in a horizontal open blow application. MINIMUM MAXIMUM NET SQ. FT. MINIMUM WEIGHT- MINIMUM MINIMUM R-VALUE BAGS PER 1000 SQ. FT. PER BAG COVERAGE POUNDS PER sa. FT. INSTALLED THICKNESS SETTLED THICKNESS To obtain a Bags per Conlents of bag Weighlpersq. ft. 01 Installed insulation Minimum settled insulation thermal resistance 1000 sq. ft. shall noleaver installed insulalion shall shall not be leSSlhan: shall not be lesslhan: (A) of: of net area: more than: (sq. fl.) not be less than: (Ibs.) (in.) (in.) 60 31.4 31.9 0.972 22.00 22,00 49 25.2 39.7 0.780 18.50 18.50 44 22.4 44.6 0,695 16.75 16.75 38 19.1 52.5 0.591 14.50 14.50' 30 14.9 67.1 0.462 11.75 11.75 26 12.8 77.9 --' 0.398 10.25 10.25 22 10.8 S'2.9 0.334 8.75 8.75 19 9.3 107.4 0.289 7.75 7.75 13 6.2 161.7 0.192 5.25 5.25 11 5.3 190.5 0.163 4.50 4.50 R-Values are determined in accordance with ASTM C687 and C518. Complies with ASTM C764 as Type 1 pneumatic Application. Initial installed thickness testing per ASTM C1374 using Unisul VoluMatic III; 4th gear; 15-inch gate opening; 150 ft. x 4-inch diameter internally corrugated blowing hose. R-VALUE To obtain a thermal resistance {Alol: 29 22 16 15 14 REQUIRED OR MINIMUM BAGS PER 1000 SQ. FT. Bags per 1000 sq. ft. 01 net area: 31.2 23.7 17.2 16.1 15.1 MAXIMUM NET SQ. FT. PER BAG COVERAGE Contents of bag shall nolcover more than: (sq. ft.l 32.1 42.3 58.1 62.0 66,4 MINIMUM WEIGHT- POUNDS PER sa. FT. Weight per sq. ft. 01 installed insulation shall not be less than: (Ibs.) 0.967 0.733 0.533 0.500 0,467 ;c o\TIONS l,;" specified when insulation -~. 'Knf J ':'/:...l" .J 5'm. "". COVERAGE CHART-CLOSED CAVITY RETROFIT (WALLS, FLOORS, CElLI",. The following thermal performances are achieved at the thicknesses, weights an : is installed with pneumatic equipment in sidewalls. Based on a design density' -'l ion '-~ than: " 6.50 4.00 3.75 3.50 READ THIS BEFORE YOU BUY What you should know about R-Values. The chart shows the R-Value of this insulation. R means resistance to heat flow. The higher the R-Value, the greater the insulating power Compare insulation R-Values before you buy. There are other factors to consider The amount of insulation you need depends mainly on the climate you live in. Also, your fuel savings from insulation will depend upon the climate, the type and size of your house, the amount of insulation already in your house, and your fuel use patterns and family size. If you buy too much insulation, it will cost you more than what you'll save on fuel. To get the marked R-Value, it is essential that this insulation be installed properly. @2007 CertainTeed Corporation A Saint-Gobain Company 30-24-298 Manufacturer Fact Insulation Sheet 2/07