HomeMy WebLinkAboutBuilding Miscellaneous 2007-8-10 ~ f\....t?''-n\ CertainTeed II Builders Statement InsulSafe@4 Fiber Glass Blowing Insulation InsuISafe"' 4 i~S been installed in accord~""C~.ilh the manufacturer's recommendations to f:t~te a value of R- .;S-using l+-bags of insulation to covr~~square feet of area at a minimum thickness Of---L..l-ft1inChes. _ Clctl :rIA 'l\J \l.l~~1/\ : . Installer/Cort\a~:or\ (s:~ I Company Name Date +'\" <\~., l",'for.oJ -''''.t:1 Builder [sign) .. f '," Gl..~any Name Date Homeow~ ~m~tbSiM.:r \,~ r '^ (I'^ eJ . ~ ~~ 4, ~ /10/0 '-t Home Address \ . .0 BATTS AND BLANKt.TS Date BAGS PER MAXIMUM MINIMUM WEIGHT- MINIMUM R~VALUE 1000 SQ. FT. . SQ. FT. PER BAG POUNDS PER SQ_ FT. THICKNESS Toob\aina Bags per Contents 01 bag Weight per sq. ft.of Should nolbe Thermal Resistance 1000sq.ft. should not cover installed insulation should less than: [Rjol: of net area: moreth"an: (sq. fL) not be less than: Qbs.) On.} 60 36.5 27 0.986 22 49 29.6 34 0.800 18'/, 44. I 26_4 !;8 I. 0.712 ~ .. --:= "-- ----A"'<: -'-- 141f. 30 18.0 56 0.485 12 26 15.5 65 0.418 10'h 22 13.1 77 0.353 ;.9 19 11.1 90 0.301 7% 13 77 129 0.209 5'. 11 66 151 0.179 40/. Inspected By (sign if required) R-Vl'Ilue Insulation Thickness (in) 38 10,12 30 8'/4,10 25 8 22 6'12 21 5'12 19 Sy. 15 3'12 13 3!J, 11 3'h Fiber glass batts or rolls have been installed in accordance with the manufacturer's recommendations to provide an R-Value of _ in the ceiling, _ in the exterior walls, _ in the floor or crawl space. THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION In accordance with the chart above, you must install the minimum number of bags per 1,000 sq. fl of net area for each R-Value listed. The maximum net coverage must not exceed that specified for each R-Value. The installed insulation must be at or above the specified minimum thickness for each R-Value. Failure to install the required minimum weight per sq. ft of insulation at or above the minimum thickness will result in reduced R-Value. This product should not be mixed with other blown insulations or the thermal claims will become invalid. R-Values are determined in accordance with ASTM C 687 and 518. Complies with ASTM C 764 as Type 1 insulation. "R" means resistance to heat flow. The higher the R-Value, the greater the insulating power. To get the desired R-Value, it is essential that the insulation is installed properly. FRAMING ADJUSTMENT , . To compensate for framing members the number of bags per 1000 sq. ft of net area should be reduced as follows: I I I I I Joist Size . (in.) ,,4 ,,6 2,8 2x10 Bags to 'deduct/lOOO sq. ft. Joists l6"O.C. Bags to deduct/lOOO sq. ft. Joists 24" D.C. 0.5 0.8 1.0 13 ,"-; ,.oJ' -fi...- -';.#~ OJ 0.5 0.7 0.9 DANGER: RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF SUCH DEVICES. DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH THERMALLY PROTECTED BALLASTS. /~, - 1.1.: -~ ., Code No. 30~24-233 A Saint-Gobain Company @2001 CertainTeed Corporation 3/01 . . . Manufacturer Insulation Fact Sheet This is CertainTeed Corporation InsulSafe@4 Fiber Glass Blowing Insulation CertainTeed II ." . ~~ Certain Teed Corporation P.O. Box 860 Valley Forge, PA 19482 '. THERMAL PERFORMANCE-HORIZONTAL OPEN BLOW \---.. . The following thermal performances are achieved at welgh~<:lIcr)Verages specified when Insulation IS Installed with ~neumatlc equipment In a hOrIZontal open blo~ appllcatlifrl: Yr} '. . I BAGS PER MAX1MUM MINIMUM WEIGHT- MINIMUM R-VALUE 1000 SQ. FT. SQ. FT. PER BAG POUNDS PER SQ. FT. THICKNESS To obt<1in J Bags per (ontcntsofbag Weightpersq. ft.oi Thermal Resistance 1000 sq. ft should nol (over ins/ailed insulation should (R) of- of net area: more than: (sq. ft.) not be Ie,s than: (Ibs.) 60 36.5 27 0.986 49 29.6 34 0.800 44 26.4 38 0.712 38 22.8 44 0.615 30 18.0 56 0.485 26 15.5 65 0.418 22 13.1 77 0.353 19 11.1 90 0.301 13 7.7 129 0.209 11 6.6 151 0.179 Should not be less than: (in.) 22 18112 16% 14% 12 101(z 9 . 7% 5Jh 4 Y4 R-values are determined in accordance with ASTM C 687 and 518. Complies with ASTM C 764 as Type 1 insulation. THERMAL PERFORMANCEc-SIDEWALL RETROFIT APPLICATION When installed with pneumatic equipment in sidewalls, the following thermal performances are achieved at th'e thicknesses, weights and coverages specified. BAGS PER MAXiMUM MINIMUM WEIGHT- MINIMUM R-VALUE 1000 SQ. FT SQ. FT. PER RAG POUNDS PER SQ. FT THICKNESS To obtain a Bags per Conlenlsofbag Weighl per sq. fl. of Should not be Therm<ll Resistance 1000 sq. ft. should nol cover installed insulation should less than: :.\ (R)of: ofllelarea: more than: (sq. ft.) not be lessth<ln: (Ibs.) (in,) ~,t 29 35.8 28 0.967 71/~ I, .if ,.;;, 22 27.2 37 0.733 5112 16 19.8 51 0.533 4 15 17.9 56 0.483 35/A 14 17.3 58 0.467 3112 \ '~1 , READ THIS BEFORE YOU BUY \ What you should know about R-Values. The chart shows the R,Value of thisinsulation. R means resistance to heat flow. The higher the R- . Value, the greater the insulating pster Compare insulation R-Values before you buy. Trere are other factors to consider. The..ib'nount of insulation you need depends mainly on the climate you live in. Also, your fuel. savings from insulation will depend upon the climate, the type and size of your house, the amount of insulation already in your house, and your fuel use r-""-.. palter'ns and family size: If you buy too much insulation, it will cost you more than what you'll save on fuel. To get the marked R-Value, it is essential that this insulation be installed properly.