~ f\....t?''-n\
CertainTeed II
Builders Statement
InsulSafe@4
Fiber Glass Blowing Insulation
InsuISafe"' 4 i~S been installed in accord~""C~.ilh the manufacturer's recommendations to f:t~te a value of
R- .;S-using l+-bags of insulation to covr~~square feet of area at a minimum thickness Of---L..l-ft1inChes.
_ Clctl :rIA 'l\J \l.l~~1/\ : .
Installer/Cort\a~:or\ (s:~ I Company Name Date
+'\" <\~., l",'for.oJ -''''.t:1
Builder [sign) .. f '," Gl..~any Name Date
Homeow~ ~m~tbSiM.:r \,~ r '^ (I'^ eJ . ~ ~~ 4, ~ /10/0 '-t
Home Address \ . .0
BATTS AND BLANKt.TS
Date
BAGS PER MAXIMUM MINIMUM WEIGHT- MINIMUM
R~VALUE 1000 SQ. FT. . SQ. FT. PER BAG POUNDS PER SQ_ FT. THICKNESS
Toob\aina Bags per Contents 01 bag Weight per sq. ft.of Should nolbe
Thermal Resistance 1000sq.ft. should not cover installed insulation should less than:
[Rjol: of net area: moreth"an: (sq. fL) not be less than: Qbs.) On.}
60 36.5 27 0.986 22
49 29.6 34 0.800 18'/,
44. I 26_4 !;8 I. 0.712 ~
.. --:= "-- ----A"'<: -'-- 141f.
30 18.0 56 0.485 12
26 15.5 65 0.418 10'h
22 13.1 77 0.353 ;.9
19 11.1 90 0.301 7%
13 77 129 0.209 5'.
11 66 151 0.179 40/.
Inspected By (sign if required)
R-Vl'Ilue Insulation
Thickness (in)
38 10,12
30 8'/4,10
25 8
22 6'12
21 5'12
19 Sy.
15 3'12
13 3!J,
11 3'h
Fiber glass batts or rolls have been installed in accordance with the manufacturer's recommendations to provide an
R-Value of _ in the ceiling, _ in the exterior walls, _ in the floor or crawl space.
THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION
In accordance with the chart above, you must install the minimum number of bags per 1,000 sq. fl of net area for each
R-Value listed.
The maximum net coverage must not exceed that specified for each R-Value.
The installed insulation must be at or above the specified minimum thickness for each R-Value.
Failure to install the required minimum weight per sq. ft of insulation at or above the minimum thickness will result in
reduced R-Value.
This product should not be mixed with other blown insulations or the thermal claims will become invalid.
R-Values are determined in accordance with ASTM C 687 and 518. Complies with ASTM C 764 as Type 1 insulation.
"R" means resistance to heat flow. The higher the R-Value, the greater the insulating power. To get the desired
R-Value, it is essential that the insulation is installed properly.
FRAMING ADJUSTMENT , .
To compensate for framing members the number of bags per 1000 sq. ft of net area should be reduced as follows:
I
I
I
I
I
Joist Size
. (in.)
,,4
,,6
2,8
2x10
Bags to 'deduct/lOOO sq. ft.
Joists l6"O.C.
Bags to deduct/lOOO sq. ft.
Joists 24" D.C.
0.5
0.8
1.0
13
,"-;
,.oJ'
-fi...- -';.#~
OJ
0.5
0.7
0.9
DANGER: RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF
SUCH DEVICES. DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH
THERMALLY PROTECTED BALLASTS.
/~,
- 1.1.:
-~
.,
Code No. 30~24-233
A Saint-Gobain Company
@2001 CertainTeed Corporation 3/01
. .
.
Manufacturer Insulation Fact Sheet
This is CertainTeed Corporation InsulSafe@4
Fiber Glass Blowing Insulation
CertainTeed II
." . ~~
Certain Teed Corporation
P.O. Box 860
Valley Forge, PA 19482
'.
THERMAL PERFORMANCE-HORIZONTAL OPEN BLOW
\---.. .
The following thermal performances are achieved at welgh~<:lIcr)Verages specified when Insulation IS Installed with
~neumatlc equipment In a hOrIZontal open blo~ appllcatlifrl: Yr} '. .
I BAGS PER MAX1MUM MINIMUM WEIGHT- MINIMUM
R-VALUE 1000 SQ. FT. SQ. FT. PER BAG POUNDS PER SQ. FT. THICKNESS
To obt<1in J Bags per (ontcntsofbag Weightpersq. ft.oi
Thermal Resistance 1000 sq. ft should nol (over ins/ailed insulation should
(R) of- of net area: more than: (sq. ft.) not be Ie,s than: (Ibs.)
60 36.5 27 0.986
49 29.6 34 0.800
44 26.4 38 0.712
38 22.8 44 0.615
30 18.0 56 0.485
26 15.5 65 0.418
22 13.1 77 0.353
19 11.1 90 0.301
13 7.7 129 0.209
11 6.6 151 0.179
Should not be
less than:
(in.)
22
18112
16%
14%
12
101(z
9 .
7%
5Jh
4 Y4
R-values are determined in accordance with ASTM C 687 and 518. Complies with ASTM C 764 as Type 1 insulation.
THERMAL PERFORMANCEc-SIDEWALL RETROFIT APPLICATION
When installed with pneumatic equipment in sidewalls, the following thermal performances are achieved at th'e
thicknesses, weights and coverages specified.
BAGS PER MAXiMUM MINIMUM WEIGHT- MINIMUM
R-VALUE 1000 SQ. FT SQ. FT. PER RAG POUNDS PER SQ. FT THICKNESS
To obtain a Bags per Conlenlsofbag Weighl per sq. fl. of Should not be
Therm<ll Resistance 1000 sq. ft. should nol cover installed insulation should less than:
:.\ (R)of: ofllelarea: more than: (sq. ft.) not be lessth<ln: (Ibs.) (in,)
~,t 29 35.8 28 0.967 71/~
I,
.if
,.;;, 22 27.2 37 0.733 5112
16 19.8 51 0.533 4
15 17.9 56 0.483 35/A
14 17.3 58 0.467 3112
\
'~1 , READ THIS BEFORE YOU BUY
\ What you should know about R-Values.
The chart shows the R,Value of thisinsulation. R means resistance to heat flow. The higher the R-
. Value, the greater the insulating pster Compare insulation R-Values before you buy.
Trere are other factors to consider. The..ib'nount of insulation you need depends mainly on the
climate you live in. Also, your fuel. savings from insulation will depend upon the climate, the type
and size of your house, the amount of insulation already in your house, and your fuel use
r-""-.. palter'ns and family size: If you buy too much insulation, it will cost you more than what you'll
save on fuel.
To get the marked R-Value, it is essential that this insulation be installed properly.