OPEN ATTIC APPLICATION
',01\
A-VALUE
To obtain a
thermal resistance
(R) of:
60
49
44
<:", ' 38
30
26
22
19
13
11
CEILINGS
WALLS
FLOORS
MINIMUM
BAGS PER 1000 SQ. FT.
Bags per
1000 sq. It
01 net area:
31.4
25.2
22.4
19,1
14.9
12.8
10.8
9.3
6.2
5.3
R-VALUE
c.S'-b
(\~ (p, ~lp
InsulSafe@ SP
Fiber Glass Blowing Insulation
~\\\r\
l-\oW\O '\21'\ 'Rnll\-+ I~)~
Company NameV
MAXIMUM NET SQ. FT.
PER BAG COVERAGE
Contents of bag
shall not cover
morelhan: (sq. ft.)
31.9
39.7
44.6
52.5
67.1
n.9
92.9
107.4
161.7
190.5
Company Name
MINIMUM WEIGHT-
POUNDS PER SQ. FT.
Weighl per sq. ft. of
installed insulation shall
not be less than: (Ibs.)
0.972
0.780
0.695
0.591
0.462
0.398
0.334
0.289
0.192
0.163
Da1e
~ -;;; R -r?l7
Date
Date
MINIMUM
INSTALLED THICKNESS
Installed insulation
shall not be less than:
(in,)
22.00
18.50
16.75
14.50
11.75
10.25
8.75
7.75
5.25
4.50
II1,b
NET AREA (Sa. FT.) INSULSAFE SP (~/" BAGS USED
L1 d:J 1/ .;c
THICKNESS
MINIMUM
SETTLED THICKNESS
Minimumsetlledinsulation
shall not be less than:
(in.)
22.00
18.50
16.75
14.50
11.75
10.25
8.75
7.75
5.25
4.50
BATTS/ROLLS (....)
THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION
o In accordance with the chart above, you must install the minimum number 01 bags per 1,000 sq. It of net area for each
R.Value listed.
o The maximum net coverage must not exceed that specified for each R.Value.
The insulation must be installed at or above the specified installed thickness for each R.Value.
o Failure to install the required minimum weight per sq. ft. of insulation at or above the initial installed thickness will result in
reduced R.Value.
o This product should not be mixed with other blown insulations or the thermal claims will become invalid.
~
DANGER: RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF
SUCH DEVICES. THIS WARNING DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT
FIXTURES WITH THERMALLY PROTECTED BALLASTS.
@2007 CertainTeed Corporation
,
A Saint-Gobain Company
"
30-24-298 Builders Statement 2/07
'1i'-'
.:~:;.
f;."i",
"., ~
. -,
Manufacturer Insulation Fact Sheet
This is CertainTeed Corporation InsulSafe@ SP
Fiber Glass Blowing Insulation
CertainTeed II
CertainTeed Corporation
P.O. Box 860
Valley Forge, PA 19482
COVERAGE CHART-OPEN ATTIC APPLICATION
The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation
is installed with pneumatic equipment in a horizontal open blow application.
MINIMUM MAXIMUM NET SQ. FT. MINIMUM WEIGHT- MINIMUM MINIMUM
A-VALUE BAGS PER 1000 sa. FT. PER BAG COVERAGE POUNDS PER SQ. FT. INSTALLED THICKNESS SETTLED THICKNESS
Tooblain a Bags per Conlents of bag Weighl per sq, ft. 01 Installed'insulation Minimum settled insulation
thermal resistance 1000 sq. ft. shall nolcover installed insulation shall shall not be less than: shall not be less than:
(R)ol: of nelarea: morelhan: (sq. ft.) not be lesslhan: (Ibs.) (in.). (in.)
60 31.4 31.9 0.972 22.00 22.00
49 25,2 39.7 0.780 18.50 18.50
44 22.4 44.6 0.695 16.75 16.75
38 19.1 52.5 0.591 14.50 14.50
30 14.9 67.1 0.462 11.75 11.75
26 12.8 77.9 0.398 10.25 10.25
22 10.8 92.9 0.334 8.75 8.75
19 9.3 107.4 0.289 7.75 7.75
13 6.2 161.7 0.192 1 5.25 5.25
11 5.3 190.5 0.163 '1 4.50 4.50
R-Values are determined in accordance with ASTM C687 and C518. Complies with ASTM C764 as Type 1 pneumatic
Application.
Initial installed thickness testing per ASTM C1374 using Unisul VoluMatic III; 4th gear; 15-inch gate opening; 150 ft x
4-inch diameter internally corrugated blowing hose.
COVERAGE CHART-CLOSED CAVITY RETROFIT (WALLS, HOORS, CEILINGS) APPLICATIONS
The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation
is installed with pneumatic equipment in sidewalls. Based on a design density of 1.6 pcf/25.6 Kg/m3
REQUIRED OR MINIMUM MAXIMUM NET SQ. FT. MINIMUM WEIGHT- INSTAllED
R-VALUE BAGS PER 1000 SQ. FT. PER BAG COVERAGE POUNDS PER SQ. FT. THICKNESS
To obtain a Bags per Contents of bag Weight per sq. ftof Installed insulation
thermal resistance 1000 sq. fl. shall not cover inslalled insulation shall shall not be less than:
(Alol: 01 net area: more than: (sq. fl.) not be less than: (Ibs.) (in.)
29 31.2 32.1 0.967 7.25
22 23.7 42.3 0.733 5.50
16 17.2 58.1 0.533 4.00
15 16.1 62.0 0.500 3.75
14 15.1 66.4 0.467 3.50
READ THIS BEFORE YOU BUY
What you should know about R-Values.
The chart shows the R-Value of this insulation. R means resistance to heat flow The higher the
R-Value, the greater the insulating power Compare insulation R-Values before you buy.
There are other factors to consider The amount of insulation you need depends mainly on the
climate you live in. Also, your fuel savings from insulation will depend upon the climate, the type
and size of your house, the amount of insulation already in your house, and your fuel use patterns
and family size. If you buy too much insulation, it will cost you more than what you'll save on fueL
To get the marked R-Value, it is essential that this insulation be installed properly
@2007 CertainTeed Corporation
A Sainl-Gobain Company
30-24-298 Manufacturer Fact Insulation Sheet '2107