OPEN ATTIC APi'LICATION
R.VAlUE
MINIMUM 1
BAGS PER 1000 sa. FT.
Bags per
1000 sq. ft.
0\ net area:
31,4
25.2
22.4"
19.1
14,9
12.8
10.8
9.3
6.2
5.3
Tooblain a
lhennal resistance
(Riot
60
49
44
38
30
26
22
19
il
- I
oft' I
13 .-i......~
~ 110>-"
<'I
,- .
. .
A-VALUE
!
CEIUNGS~
~-3R
~~
\;
WALLS
FLOORS
..
~,\n'\\~
InsulSafe@ SP
Fiber Glass Blowing Insulation
('t
. . ---:->
\\OW\l' Ll\>",O\P..\DN CO
Company Name
MAXIMUM NET sa. FT.
PEA BAG COVERAGE
Contents of bag
shall not cover
morelhan:.(sq. ft.)
31.9
39.7
44.6
52.5
67.1
77.9
92.9
107.4
161.7
190.5
"
THICKNESS
14,5()
Company Name
I
I
I
'I
MINIMUM WEIGHT-
POUNDS PER sa. FT.
Weightpersq.ft,of
installed insulation shall
nolbelesslhan:(lbs.}
0.972
0.780
0.695
0.591
0.462
0.398
0.334
0.289
0.192
0.163
Date
\;::}." 5-~()07
Date
Date
MINIMUM
INSTALLED THICKNESS
Installed insulation
shall not be less than:
(in.)
22.00
18.50
16.75
14.50
11.75
10.25
8.75
7.75
5.25--
4.50
BAGS USED
riQ
I
MINIMUM
SETTLED THICKNESS
Minimum sellled insulation
shall not be less than:
(in.)
22.00
18.50
16.75
14.50
11.75
10,25
8.75
7.75
5.25
4.50
BATTS/ROLLS (....)
'.'
THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION
. In accordance with the chart above, you must install the minimum number of bags per 1,000 sq. ft. of net area for each
R-Value listed.
. The maximum net coverage must not exceed that specified for each R.Vaiue.
. The insulation musl be installed at or above the specified installed thickness for each R.Value.
. . .
. Failure to install the required minimum weight per sq. ft of insulation at or above the initial installed thickness will result in
reduced R.Value. .
. This product should not be mixed with other blown insuiations or the thermal claims will become invalid.
NET AREA (sa. FT.) INSULSAFE SP (....)
\-i on
II
DANGER: RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF
SUCH DEVICES. THIS WARNING DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT
FIXTURES WITH THERMALLY PROTECTED BALLASTS.
@2007 CertainTeed Corporation
A Saint-Gobain Company
30-24-298 Builders Statement 2107
1 "\""
,-:;.:
Manufacturer Insulation Fact Sheet
This is CertainTeed Corporation InsulSafe@ SP
Fiber Class Blowing Insulation
CertainTeed Corporation
PO. Box 860
Valley Forge, PA 19482
CertainTeed.
COVERAGE CHART-OPEN ATTIC APPLICATION
The following thermal perf,?rr.nances are achieved at the thicknesses, weights and coverages specified when insulation
is installed with pneumatic equipment in a horizontal open blow application.
MINIMUM MAXIMUM NET sa. FT. MINIMUM WEIGHT- MINIMUM MINIMUM
R-VALUE BAGS PER 1000 SO.FT. PER BAG COVERAGE POUNDS PER SO. FT. INSTALLED THICKNESS SETTLED THICKNESS
To obtain a Bags per Contents of bag Weightpersq.ft,of Installed insulation Minimum settled insulation
thennal resistance 1000 sq. ft. shall not cover instailed insuiation shall shali nolbe less than: shall not be less than:
(R) of: , of net area: more than: (Sq. ft.} not be lesslhan: (Ibs,) (in.) (I,.)
60 31.4 31.9 0.972 22.00 22.00
49 25.2 39.7 0.780 18,50 18,50
44 22.4 44,6 0,695 16.75 16,75
38 19.1 52.5 0.591 14.50 14.50
30 14.9 67.1 0.462 11.75 11.75
26 12.8 77.9 0.398 10.25 10.25
22 10.8 92.9 0.334 8.75 8.75
19 93 107.4 0,289 7.75 7.75
13 6.2 161.7 0.192 5.25 5.25
11 5.3 190.5 0.163 4.50 4.50
R-Values are determined in ac'i:o'rdance with ASTM C687 and C518. Complies with ASTM C764 as Type 1 pneumatic
Application.
Initial installed thickness testing per ASTM C1374 using Unisul VoluMatic III; 4th gear; 15-inch gate opening; 150 ft. x
4-inch diameter internally co!~~gated blowing hose.
COVERAGE CHART-CLOSED CAVITY RETROFIT (WALLS, FLOORS, CEILINGS) APPLICATIONS
"
The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation
is installed with pneumatic equipment in sidewalls. Based on a design density of 1.6 pcf/25.6 Kg/m3
, REQUIRED OR MINIMUM MAXIMUM NET SQ. Ff. MINIMUM WEIGHT- INSTALLED
R-VAlUE BAGS PEA 1000 sa. FT. PEA BAG COVERAGE POUNDS PER SQ. FT. THICKNESS
To obtain a Bags per Contents of bag Weighl per sq. 11. of Inslalledinsulation
thermal resistance 1000 sq. fl. shall not cover installed insulalion shall shall not be less lhan:
(R) of: of net area: more than: (sq. It.) not be less than: (Ibs.) (in.)
29 31.2 32.1 0.967 7.25
22 23.7 42.3 0,733 5.50
16 17.2 58.1 0.533 4.00
15 16.1 62.0 0.500 3.75
'4 15.1 66.4 0.467 3,50
READ THIS BEFORE YOU BUY
What you should know about R-Values.
The chart shows the R-Value of this insulation. R means resistance to heat flow. The higher the
R-Value, the greater the insulating power. Compare insulatio'n R-Values before you buy.
There are other factors to consider. The amount of insulation you need depends mainly on the
climat~ you live in. Also, your fuel savings from insulation will depend upon the climate, the type
and size of your house, the amount of insulation already in your house, and your fuel use patterns
and family size. If you buy too much insulation, it will cost you more than what you'll save on fueL!
. To get th~ m'arked R-Value, it is essential that this insulation be installed properly. ../7
@2007 CertainTeed Corporation
A Salnt-Gobain Company
30-24-298 Manufacturer Fact Insulation Sheet.2/07