HomeMy WebLinkAboutBuilding Miscellaneous 2007-12-5 CertainTeed II Builders Statement Homeowner Name / Jobsite Name I geq KhJ~4'\.\c'l\:Jf'\j Home AddreSs r ~,Ol)'_.rr/')~ rS.Uc.DL Installer I Contractor (sign) Builder (sign) Inspected By (sign if required) OPEN ATTIC APi'LICATION R.VAlUE MINIMUM 1 BAGS PER 1000 sa. FT. Bags per 1000 sq. ft. 0\ net area: 31,4 25.2 22.4" 19.1 14,9 12.8 10.8 9.3 6.2 5.3 Tooblain a lhennal resistance (Riot 60 49 44 38 30 26 22 19 il - I oft' I 13 .-i......~ ~ 110>-" <'I ,- . . . A-VALUE ! CEIUNGS~ ~-3R ~~ \; WALLS FLOORS .. ~,\n'\\~ InsulSafe@ SP Fiber Glass Blowing Insulation ('t . . ---:-> \\OW\l' Ll\>",O\P..\DN CO Company Name MAXIMUM NET sa. FT. PEA BAG COVERAGE Contents of bag shall not cover morelhan:.(sq. ft.) 31.9 39.7 44.6 52.5 67.1 77.9 92.9 107.4 161.7 190.5 " THICKNESS 14,5() Company Name I I I 'I MINIMUM WEIGHT- POUNDS PER sa. FT. Weightpersq.ft,of installed insulation shall nolbelesslhan:(lbs.} 0.972 0.780 0.695 0.591 0.462 0.398 0.334 0.289 0.192 0.163 Date \;::}." 5-~()07 Date Date MINIMUM INSTALLED THICKNESS Installed insulation shall not be less than: (in.) 22.00 18.50 16.75 14.50 11.75 10.25 8.75 7.75 5.25-- 4.50 BAGS USED riQ I MINIMUM SETTLED THICKNESS Minimum sellled insulation shall not be less than: (in.) 22.00 18.50 16.75 14.50 11.75 10,25 8.75 7.75 5.25 4.50 BATTS/ROLLS (....) '.' THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION . In accordance with the chart above, you must install the minimum number of bags per 1,000 sq. ft. of net area for each R-Value listed. . The maximum net coverage must not exceed that specified for each R.Vaiue. . The insulation musl be installed at or above the specified installed thickness for each R.Value. . . . . Failure to install the required minimum weight per sq. ft of insulation at or above the initial installed thickness will result in reduced R.Value. . . This product should not be mixed with other blown insuiations or the thermal claims will become invalid. NET AREA (sa. FT.) INSULSAFE SP (....) \-i on II DANGER: RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF SUCH DEVICES. THIS WARNING DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH THERMALLY PROTECTED BALLASTS. @2007 CertainTeed Corporation A Saint-Gobain Company 30-24-298 Builders Statement 2107 1 "\"" ,-:;.: Manufacturer Insulation Fact Sheet This is CertainTeed Corporation InsulSafe@ SP Fiber Class Blowing Insulation CertainTeed Corporation PO. Box 860 Valley Forge, PA 19482 CertainTeed. COVERAGE CHART-OPEN ATTIC APPLICATION The following thermal perf,?rr.nances are achieved at the thicknesses, weights and coverages specified when insulation is installed with pneumatic equipment in a horizontal open blow application. MINIMUM MAXIMUM NET sa. FT. MINIMUM WEIGHT- MINIMUM MINIMUM R-VALUE BAGS PER 1000 SO.FT. PER BAG COVERAGE POUNDS PER SO. FT. INSTALLED THICKNESS SETTLED THICKNESS To obtain a Bags per Contents of bag Weightpersq.ft,of Installed insulation Minimum settled insulation thennal resistance 1000 sq. ft. shall not cover instailed insuiation shall shali nolbe less than: shall not be less than: (R) of: , of net area: more than: (Sq. ft.} not be lesslhan: (Ibs,) (in.) (I,.) 60 31.4 31.9 0.972 22.00 22.00 49 25.2 39.7 0.780 18,50 18,50 44 22.4 44,6 0,695 16.75 16,75 38 19.1 52.5 0.591 14.50 14.50 30 14.9 67.1 0.462 11.75 11.75 26 12.8 77.9 0.398 10.25 10.25 22 10.8 92.9 0.334 8.75 8.75 19 93 107.4 0,289 7.75 7.75 13 6.2 161.7 0.192 5.25 5.25 11 5.3 190.5 0.163 4.50 4.50 R-Values are determined in ac'i:o'rdance with ASTM C687 and C518. Complies with ASTM C764 as Type 1 pneumatic Application. Initial installed thickness testing per ASTM C1374 using Unisul VoluMatic III; 4th gear; 15-inch gate opening; 150 ft. x 4-inch diameter internally co!~~gated blowing hose. COVERAGE CHART-CLOSED CAVITY RETROFIT (WALLS, FLOORS, CEILINGS) APPLICATIONS " The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation is installed with pneumatic equipment in sidewalls. Based on a design density of 1.6 pcf/25.6 Kg/m3 , REQUIRED OR MINIMUM MAXIMUM NET SQ. Ff. MINIMUM WEIGHT- INSTALLED R-VAlUE BAGS PEA 1000 sa. FT. PEA BAG COVERAGE POUNDS PER SQ. FT. THICKNESS To obtain a Bags per Contents of bag Weighl per sq. 11. of Inslalledinsulation thermal resistance 1000 sq. fl. shall not cover installed insulalion shall shall not be less lhan: (R) of: of net area: more than: (sq. It.) not be less than: (Ibs.) (in.) 29 31.2 32.1 0.967 7.25 22 23.7 42.3 0,733 5.50 16 17.2 58.1 0.533 4.00 15 16.1 62.0 0.500 3.75 '4 15.1 66.4 0.467 3,50 READ THIS BEFORE YOU BUY What you should know about R-Values. The chart shows the R-Value of this insulation. R means resistance to heat flow. The higher the R-Value, the greater the insulating power. Compare insulatio'n R-Values before you buy. There are other factors to consider. The amount of insulation you need depends mainly on the climat~ you live in. Also, your fuel savings from insulation will depend upon the climate, the type and size of your house, the amount of insulation already in your house, and your fuel use patterns and family size. If you buy too much insulation, it will cost you more than what you'll save on fueL! . To get th~ m'arked R-Value, it is essential that this insulation be installed properly. ../7 @2007 CertainTeed Corporation A Salnt-Gobain Company 30-24-298 Manufacturer Fact Insulation Sheet.2/07