Loading...
HomeMy WebLinkAboutBuilding Miscellaneous 2007-11-14 CertainTeed II Builders Statement Hom~~B~JObsiteN~eINS \-~~\'1 ('~\- ~. Home Address ~ I.- ", ~ ,00 l.in"" r-". w D.C'Q.... Installer / Contractor (sign") ~ Builder (sign) Inspected By (sign if required) OPEN ATTIC APPLICATION A.VALUE ~- Tooblain a thermal resistance (R) of: 60 49 44 38 * 30 26 22 19 13 11 CEILINGS WALLS FLOORS MINIMUM BAGS PER 1000 SQ. FT. Bags per 1000 sq. ft of net area: 31.4 25.2 22.4 19.1 14.9 12.8 10.8 9.3 6.2 5.3 R.VALUE r~B MAXIMUM NET SQ. FT. PEA BAG COVERAGE Conlents of bag shallnolcover more than: (sq. ft.) 31.9 39.7 44.6 52.5 67.1 77.9 92.9 107.4 161.7 190.5 THICKNESS 1450 ~ .In-\\\O [ ~~ InsulSafe@ SP Fiber Glass Blowing Insulation I~()l)'() ~<'L> \~L~ Company Name Company Name t \ MINIMUM WEIGHT- POUNDS PER sa, IT. Weighl persq, ft. of installed insulalion shall nathe less than: (Ibs.) 0.972" '\ 0.780 ) 0.695 , "---- 0.591/ --0.462 0.398 0,334 0.289 0.192 0.163 c=- l \ 114/~1-- Date I Date Date MINIMUM INSTALLED THICKNESS Installed insulation shall not be less than: (in.) 22.00 18.50 16.75 14.50 11.75 10.25 8.75 7.75 5.25 4.50 BAGS USED d,&; MINIMUM SETTLED THICKNESS Minimum settled insuiation shall not be less than: (in.) 22.00 18.50 16.75 14.50 11.75 10.25 8.75 .-' 7.75 5.25 4.50 BATTSIROLLS (....) 0' Q THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION . In accordance with the chart above, you must install the minimum number of bags per 1,000 sq. ft of net area lor each R.Value listed. . The maximum net coverage must not exceed that specified for each R.Value. . The insulation must be installed at or above the specified installed thickness lor each R.Value. . Failure 10 install the required minimum weight per sq. ft 01 insulation at or above the initial installed thickness will result in reduced R-Value. . This product should not be mixed with other blown insulations or the thermal claims will become invalid. NET AREA (sa. n) INSULSA~) I/' DANGER: RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF SUCH DEVICES. THIS WARNING DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR .TO FLUORESCENT FIXTURES WITH THERMALLY PROTECTED BALLASTS" ':) 0 Of 30-24-298 Builders Statement 2/07 @2007CertainTeed Corporation \~\C) : ,,'" --, 0 A Saint-Gobain Company ~ . .. ---" Manufacturer Insulation Fact Sheet This is CertainTeed Corporation InsllIlSafe@ SP Fiber Glass Blowing Insulation CertainTeed Corporation P.O. Box 860 Valley Forge, PA 19482 CertainTeed. COVERAGE CHART-OPEN ATTIC APPLICATION The following. thermal performances are achieved at the thicknesses, weights and coverfges specified when insulation is installed with pneumatic equipment in a horizontal open blow application. R-VALUE MINIMUM BAGS PER 1000 SQ. FT. MINIMUM WEIGHT- POUNDS PER sa. FT. MAXIMUM NET SQ. FT. PER BAG COVERAGE MINJMUM INSTALLED THICKNESS Installed insulation shall not be lesslhan: (in.) 22.00 18,50~ . 16.75 14.50 11.75 10.25 MINIMUM SETTLED THICKNESS To obtain a Bags per Contents of bag Weight per sq. ft. of thermal resistance 1000 sq. fl. shall not cover installed insulation shall (R) of: of net area: more than: (sq. ft.) not be less than: (Ibs.) 60 31.4 31.9 0.972 49 25.2 39.7 0.780 44 22.4 44.6 0.695 38 19.1 52.5 0.591 30 14.9 67.1 0.462 26 12.8 77.9 0.39a 22 10.8 92.9 0.334 19 9.3 107.4 0.289 13 6.2 161:7 ~_ 0.192 11 I 5.3 190:5 -C' - '\ 0.163 \ ...J R-Values are determined in accordance with ASTM~and C518. Complies with ASTM C764 as Type 1 pneumatic Application. 8.75 7.75 5.25 4.50 Minimum settled insulation shall nolbe less than: (in.) 22.00 18.50 16.75 14.50 11.75 10.25 8.75 7.75 5.25 4.50 Initial installed thickness testing per ASTM C1374 using Unisul VoluMatic III; 4th gear; 15-inch gate opening; 150 ft x 4-inch diameter internally corrugated blowing hose. COVERAGE CHART-ClOSED CAVITY RETROFIT (WALLS, FLOORS, CEILINGS) APPLICATIONS The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation is installed with pneumatic equipment in sidewalls. Based on a design density of 1.6 pcf/25.6 Kglm3 REQUIRED OR MINIMUM MAXIMUM NET SQ, FT. MINIMUM WEIGHT- INSTAllED R-VAlUE BAGS PER 1000 SQ. FT. PER BAG COVERAGE POUNDS PER SQ. FT. THICKNESS To obtain a Bags per Contents of bag Weight per sq, ft. of Installed insulation thermal resistance 1000sq_ft shall not cover installed insulation shall shall not be less than: (R) of: of net area: more than: (sq. ft.) not be less than: (Ibs.) (in.) 29 31,2 32.1 0.967 7.25 22 23.7 42.3 0.733 5.50 16 17.2 58.1 0.533 4.00 . 15 16.1 62.0 0.500 3.75 14 15.1 66.4 0.467 3.50 READ THIS BEFORE YOU BUY What you should know about R-Values. The chart shows the R-Value of this insulation. R means resistance to heat flow. The higher the R-Value, the greater the insulating power. Compare insulation R-Values before you buy. There are other factors to consider. The amount of insulation you need depends mainly on the climate you live in. Also, your fuel savings from insulation will depend upon the climate, the type and size of your house, the amount of insulation already in your house, and your fuel use patterns and family size. If you buy too much insulation, it will cost you more than what you'll save on fuel. To get the marked R-Value, it is essential that this insulation be installed properly. @2007 CertainTeed Corporation A Saint-Gobain Company 30-24-298 Manufacturer Fact Insulation Sheet 2107